EX330/EW330/EX330(1W)/EW330(1W)
Confidential
4-2
4-4 Test Condition
- Circumstance brightness: Dark room less than 10.0 lux.
- Inspection distance: 1.8m~2.5m functional inspection.
- Screen size: 60 inches diagonal
- After repairing each
unit
, the unit should be run-in (refer to the table below)
Symptom
Run-in Time
Normal repair
2 hours
NFF
4 hours
Auto shut down
6 hours
- Enter Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press " Power -> Left -> Left -> Up"
Choose Burn-In Test > enter
Lamp On (Min)
Press right key to adjust the time (50)
Lamp Off (Min)
Press right key to adjust the time (10)
Set burn in cycle
Press right key to adjust the cycle
After setting up the time, choose Burn-In mode and hit enter
Screen Defects (While replacing DMD Chip, DMD BD and MB)
< Figure: Zone A &B Definition >
Содержание EW330
Страница 58: ...EX330 EW330 EX330 1W EW330 1W Confidential Assy Optical Engine Module EX330 25...
Страница 60: ...EX330 EW330 EX330 1W EW330 1W Confidential VII D C EX330 A 24...
Страница 61: ...EX330 EW330 EX330 1W EW330 1W Confidential VIII D C EX330 B 23 25 26 27...
Страница 63: ...EX330 EW330 EX330 1W EW330 1W Confidential D P EX330 22...