9-6
EP731
SERVICE MANUAL
Introduction Fundamental Principle Mechanical Construction Procedure of Disassembly Function of Boards Specifications
Troubleshooting Function Test and Alignment Procedure Firmware Upgrading Procedure
DDC Key-In Procedure
Appendix
3.
And the following picture will show on the screen.
4.
Key S/N into the blank space beside Bar Code, then press Enter key on keyboard to
begin programming.
5.
After finishing the above actions, PASS will appear on the screen.
PASS signal
6.
Power on EP731, then input digital signal. If there is no display, it means EDID is not keyed in
sucessfully. Please repeat the step 1~5 again.
(Note : Cant run two EDID programs at the same time.)