background image

 

 

YG2 / YS2

 

20 / 21

 

Rev. 2.3

 

 

Warranty 

Summary of Warranty 

OPTOCORE YG2/YS2 device is warranted against defects in material and workmanship for 60 months (5 years) 
from the date of purchase. This warranty does not include mechanical damages caused by misuse. This warranty 
covers  the  original  registered  purchaser  only  and  is  not  transferable.  This  warranty  does  not  apply  to  devices 
which have been purchased in used condition or demonstrator equipment. 

OPTOCORE  will,  at  its  discretion,  repair  or  replace  a  defective  product,  providing  that  the  defect  has  occurred 
under normal operating conditions. 

This  warranty  does  not  cover  damage  from  acts  of  God,  accident,  abuse,  neglect,  contamination,  unauthorised 
modification,  misuse,  or  operation  outside  of  the  environmental  specifications  for  the  product,  improper  site 
preparation  or  maintenance,  or  abnormal  conditions  of  handling.  This  would  include  over-voltage  failures,  and 
conditions outside of the products specified ratings, problems with customer-supplied software or interfacing, or 
normal wear and tear of mechanical components. OPTOCORE will acknowledge the evaluation of warranty after 
inspection. 

Not  covered  by  this  warranty  are  defects  arising  from  electromagnetic  or  electrical  interferences,  deficiency, 
excess, or surge of electrical supply, air conditioning, or humidity. This also includes repairs made necessary by 
dirt, abrasion, moisture, rust, corrosion, or similar conditions. 

Devices on which the Serial Number has been removed or defaced are not eligible for warranty service. 

OPTOCORE  devices  contain  no  user-serviceable  components:  refer  to  qualified  service  personnel  for  repair  or 
upgrade.  The  warranty  will  be  void  if  you  tamper  with  internal  components.  Please  address  any  questions  or 
inquiries to OPTOCORE or your distributor/dealer. 

For a full warranty conditions refer to the Warranty Card attached to every Optocore device with a first shipment. 

How to Obtain Warranty Service 

When  discovering  a  problem  with  an  OPTOCORE  device,  you  should  contact  either  Optocore  directly  or  a 
dealer/distributor  to  determine  and  confirm  a  hardware  fault.  If  it  is  a  software  issue  the  hardware  must  not  be 
returned to OPTOCORE, OPTOCORE will issue a support ticket in this case.  

If hardware service is required within the warranty period, take the equipment, along with warranty  card, to  the 
nearest  authorised  OPTOCORE  dealer/distributor.  The  dealer/distributor  will  make  sure  that  the  device  is 
serviced according to the terms of warranty by OPTOCORE or an authorised service centre. 

If the equipment needs to be returned directly to OPTOCORE, first contact [email protected]

OPTOCORE requires the serial number of the equipment intended for return, as well as a short description of the 
problem.  If  possible,  you  should  also  provide  us  a  phone  number  where  you  can  be  reached  during  regular 
working  hours.  To  return  a  defective  product,  please  contact  your  distributor  /  dealer.  Our  web  site: 

http://www.optocore.com/

 provides a complete list of Optocore distributors / dealers. 

Make  sure  the  equipment  being  returned  is  packed  carefully  to  protect  it  from  damage  during  shipment. 
OPTOCORE requires that shipments are pre-paid and insured – unless specifically authorized in advance.  

We strongly advise not to use simple flight-cases without rack-in-rack mounting. 

Declaration of Liability 

Optocore accepts no liability for damage caused to other devices through operation of the YG2/YS2 device. 

Optocore is not liable for any damage caused by shipping accidents, misuse, abuse, operation with incorrect AC 
voltage, operation with faulty peripheral equipment, or improper or careless installation of the device. 

Neither OPTOCORE nor anyone involved in the production of the equipment shall be liable for 
any indirect, special, disciplinary, consequential, or incidental damages arising out of the use 
or  inability  to  use  this  equipment  even  if  OPTOCORE  has  been  advised  of  the  possibility  of 
such damages. In no event shall the liability of OPTOCORE exceed the purchase price of any 
defective equipment.

 

Optocore accepts no claims for compensation whatsoever (e.g. cancellation of events). 

Содержание YG2

Страница 1: ...amaha Operating Manual Rev 2 3 Operating Manual for OPTOCORE YG2 YS2 OPTICAL DIGITAL miniYGDAI cards for YAMAHA DEVICES Optical Network I O Cards Copyright 2020 All rights reserved OPTOCORE GmbH Alte Allee 28 81245 Munich Germany ...

Страница 2: ...Page intentionally left blank ...

Страница 3: ...perating manual Do not place the card near any heat source such as radiators power amplifiers or any other heat producing equipment Never switch on power amplifiers before the complete system is stable and the level meters of the OPTOCORE CONTROL software indicate a normal level The card may only be used in accordance to the information provided in this operating manual Ensure that all recommendat...

Страница 4: ...lectrical components directly While inserting the card into the slot of a console hold the card at its front panel or by the use of rack mount screws Environments This device can be used in E1 E2 E3 E4 or E5 environments as listed below according to the harmonised European standards EN55103 1 and EN55103 2 Electromagnetic compatibility Product family standard for audio video and audio visual and e...

Страница 5: ...n the casing They may come into contact with dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the device Cables and Accessories Only use attachments that are specified by the manufacturer of the device Use high quality properly terminated cables to connect the device Servicing Do not attempt to service this device yourself ...

Страница 6: ...onable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which ...

Страница 7: ...ission Delay 10 Control 10 Front Panel YS2 11 YS2 Cards Details 12 Digital Audio 12 SUB Port 12 Starting Up 13 Hardware Connection 13 Optocore Network Setup 13 Connectors and Cables 14 Optical Connection 14 MAIN SUB Ports 14 RS232 Connection 14 Connector Hood Quality 14 USB Connection 14 LAN Connection 14 Network Example 15 Device Compatibility 16 Connection Tables 17 YG2 Cards D SUB9 Connector 17...

Страница 8: ...veral outstanding features Two LC type optical interfaces for data transmission into the Optocore network and connection of any Optocore device for instance the DD32R FX X6R FX One RJ45 LAN port for connection of any standard 10 100MBit Ethernet device transport of control or any Ethernet compatible data via the Optocore network USB RS232 Remote D Sub 9 port for remote control software update conn...

Страница 9: ...r remote control via PC 2 x RS422 ports e g for Yamaha HA Remote protocol exchange with console Use the TRI Y cable provided with the YG2 card See chapter Connection Tables for detailed pin out For updating via PC a standard RS232 cable is sufficient LINK 1 Full duplex full bandwidth LC type optical interface for Optocore transmission SFP multimode transceiver included singlemode transiver option ...

Страница 10: ...the console LAN Port A 10 100 Mbps Fast Ethernet interface is provided via RJ45 port All LAN ports of the Optocore devices within the Optocore network form a virtual switch with physically distributed ports We recommend using a standard CAT5 network cables to connect any Ethernet device such as a standard Ethernet switch for local distribution SUB Port The SUB port offers the possibility to extend...

Страница 11: ...232 plug RS232 port for upgrading the cards internal logic via PC SUB port RJ45 port for connection towards the MAIN port of YS2 card with CAT5 cable MAIN port RJ45 port for connection towards the SUB port of a YG2 or YS2 card with CAT5 cable ...

Страница 12: ... for Yamaha consoles providing 8IN 8OUT audio channels such as the DIO8 Please refer to chapters Optocore Network Setup and Device Compatibility SUB Port The SUB port offers the possibility to extend the number of channels transmitted to the console if connected to the MAIN port of an YS2 card using a standard CAT5 cable MAIN Port The MAIN port is connected to the SUB port of an YG2 card In a chai...

Страница 13: ...YG2 card inserted in the main console when using several consoles to ID1 and check the Master Priority flag This determines the card to be the internal word clock master for the Optocore network General Card ID Set the ID to either MY 16AT emulation or MY 8AT emulation depending on the standards of the console Please refer to the chapter Device Compatibility which settings apply for your console H...

Страница 14: ...d Cables Optical Connection Multimode transceivers connected using a 50 µm OM3 fibre cable can be used for applications requiring cable lengths of up to 700 m worst case Single mode transceivers connected using a 9 µm fibre cable can be used for applications requiring cable lengths of up to 70 km worst case The total optical loss should be less than 6dB between transceivers For portable applicatio...

Страница 15: ... console with YG2 YS2 cards In order to control the X6R converter at the console the Yamaha Emulation Mode YEM must be activated in OPTOCORE CONTROL Yamaha preamps connected to the DD32R will use the fiber optical connection only for the bi directional transfer of RS485 data and no special mode is activated ...

Страница 16: ...6AT emulation or MY 8AT emulation according to the number of channels supported 16 IN 16 OUT MY 16AT Up to 4 x YG2 YS2 TP 64 IN 64 OUT 8 IN 8 OUT MY 8AT 8 x YG2 YS2 64 IN 64 OUT PM5D PM5D RH DIO8 for PM1D PM1DV2 M7CL Series DME32 LS9 Series with HA remote transport via slot AD824 DM2000 DA824 DM1000 02R96 01V96 DME64N DME24N CL Series QL Series Rivage PM10 All future products with Mini YGDAI slots...

Страница 17: ... modem cable male female to connect to PC Consider non standard pinning RXD TXD Pin 3 2 5 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC TRI Y Adapter The TRI Y cable combines the two RS422 and the USB Port for PC connection in one D Sub 9 connector It is used to establish the connection from the YG2 Card to a PC USB interface and remote interface of a console YG2 Auxiliary Port 2 x RS422 a...

Страница 18: ...ltimode fiber 62 5µm 350m not recommended Monomode fiber 9µm up to 70km on request Auxiliary Ports Convention EIA TIA 422 Data channels Digital control data 1 IN 1 OUT up to 1Mbps RS232 Port Convention EIA TIA 232 Data channels Digital control data R x D T x D Data rate 57 600 Baud SUB Port Convention Optocore 64 channel CAT5 Cable Type ANSI TIA EIA 568 A TSB 95 CAT5 Max Cable length 10 m 33 feet ...

Страница 19: ... Weight 365 g 12 88 ounces YS2 Card Weight 175 g 6 17 ounces Package Dimensions YG2 YS2 Card H x B x T 170 x 225 x 85 mm H x W x D 6 69 x 8 86 x 3 35 inch Package Weight YG2 Card Weight 540 g 19 4 ounces YS2 Card Weight 320 g 11 3 ounces Please note Modifications that serve the purpose of technical improvement may be carried out without prior notification ...

Страница 20: ...problem with an OPTOCORE device you should contact either Optocore directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to OPTOCORE OPTOCORE will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest authorised OPTOCOR...

Страница 21: ... following 1 x YS2 Yamaha Mini YGDAI card 1 x CAT5 Cable length 0 25 m 0 82 ft Any additionally purchased equipment such as optical waveguide cables in required lengths D Sub cables and adapters RS232 cables and international electric cables have been supplied on your request and your purchase order and cannot be listed in the above Company Information Mailing Address OPTOCORE GmbH Alte Allee 28 8...

Отзывы: