YG2 / YS2
14 / 21
Rev. 2.3
YS2 Card
•
General -> Card ID:
Set it either to “MY-16AT emulation” or “MY-8AT emulation” depending on the
standards of the console. Please refer to chapter “Device Compatibility” which settings to use for your
console.
Push button “Write” first, confirm with “OK” and press “Close” to exit the dialog.
Check your console if all cards inserted in the slots have been recognized correctly (please refer to your consoles
manual how to do). If you have changed the default settings for “Card ID”, a restart of your console is necessary
after the change in order to recognize the cards correctly.
You may now connect the optical LINK cables between all Optocore devices.
Note: When connecting the optical LINK cables, for convenience temporarily remove the TRI-Y cable. This
especially counts for removing the optical cables.
Check your set-up by connecting to any device using either RS232 or USB connection, running the OPTOCORE
CONTROL software and starting “Online Mode” in the “Set” menu. The entire network at its current state is now
displayed in the control software. Check the “log window” for any error messages.
Optionally you may connect the TRI-Y cable to the HA Remote port of your console and attach any Ethernet
device to the LAN port of your YG2 card.
Connectors and Cables
Optical Connection
Multimode transceivers connected using a 50
µ
m OM3 fibre cable can be used for applications requiring cable
lengths of up to 700 m (worst case).
Single mode transceivers connected using a 9
µ
m fibre cable can be used for applications requiring cable lengths
of up to 70 km (worst case).
The total optical loss should be less than 6dB between transceivers.
For portable applications, such as touring and other temporary installations, ruggedized HMA Expanded Beam
Connectors, mounted on 1 RU panels and portable cables on cable drums are available.
Please refer to the Product Brochure available at www.optocore.com.
MAIN/SUB Ports
Use standard, fully wired, twisted pair cable (Cat 5, Cat 5e, Cat 6) terminated with RJ-45 connectors.
RS232-Connection
Use a standard shielded RS232 cable.
Connector Hood Quality
Locking screws for D-Sub connectors should be compatible with 4-40 UNC. Care should be taken in selecting the
right type of connector hoods in order to fulfil the requirements of EMI-radiation directives. Full metal connector
hoods should be used, approved acc. to VDE 0871, FCC 20780 and EMC directive 2004/108/EG, providing
attenuation > 40 dB between 30 MHz up to 1 GHz. The shield of the cable should have contact to the connector
hood
.
USB-Connection
The D-SUB9 connector also provides an USB port. Use the TRI-Y cable, which is provided with every YG2/YS2
card.
LAN-Connection
Use a standard twisted pair cable (Cat-5, Cat-6) with RJ-45 connectors.
Содержание YG2