background image

 

 

 

DD32R-FX

 

15 / 26 

rev. 2.4

 

Device Details 

Optocore Fiber Optic Connection 

The  device  is  equipped  with  the  Optocore  FX  communication  module.  The  OPTOCORE  ®  OPTICAL  DIGITAL 
NETWORK SYSTEM utilizes Time Division Multiplex technology (TDM) with a Fibre Channel based 8B10B-NRZI-
coding.  Static  time  slots  guarantee  a  synchronous  transmission  of  all  channels,  at  all  times,  without  the  use  of 
dynamic bandwidth or latency. All signals connected to the intercom, audio, video, word clock and auxiliary ports 
of  the  device  are  transmitted  simultaneously  on  one  fibre  while  the  second  fibre  of  the  LINK-Interface  receives 
data from the network. The second LINK-Interface pair is identical to the first one, and can optionally be used for 
network redundancy 

Principal Ports for AES/EBU 

According to the AES/EBU standard each physical channel contains two audio channels - with the 32 digital  of 
the four principle ports 64 audio channels are available. The ports  feature  the unique possibility  to define  them 
freely as AES/EBU inputs or AES/EBU outputs in groups of four. 

OPTOCORE CONTROL software should be used to enable, disable and configure 32 digital channels as inputs 
or outputs in groups of four. For more details refer to the Optocore Control Software Manual. 

 

 

 

SANE Ports 

The device is equipped with two RJ45 200MBit SANE Ports, capable of transmitting 64 channels of synchronous 
audio and 100MBit Ethernet. SANE 2 port is compatible with MADI over Cat protocol 

RS485 

The  auxiliary  ports  provide  four  RS485  ports  to  establish  a  maximum  of  four  half-duplex  or  two  full-duplex 
connections between devices. A wide range of bi-directional and unidirectional standards can be connected to the 
ports,  such  as  RS485,  CAN-Bus  (bi-directional,  requires  special  firmware  version),  or  RS422,  DMX  and  MIDI 
(unidirectional).  The  ports  automatically  sense  whether  they  are  sending  or  receiving  control  data.  
The ports and their destinations are configured in the OPTOCORE CONTROL software. 

Word Clock 

Devices  with  Optocore/SANE  modules  are  equipped  with  an  internal,  high  quality,  low  jitter  clock  generator  as 
well as Word Clock inputs and outputs. Any device on the network can act as the master of the network and pass 
Word Clock to networked Optocore/SANE devices.  
The internal/networked Word Clock is available at the Word Clock output connector of each device on the network 
to synchronize non-networked devices.  
In standalone network configurations external synchronization is not required. 
The  Word  Clock  input  termination  can  be  switched  on  using  the  OPTOCORE  CONTROL  software’s  Local 
Settings. External termination is not required to avoid cable reflections. 
Word Clock master negotiation after any Word Clock source failure is done automatically..  

Video Ports 

A video

 

in- and output is integrated for the transmission of composite video signals. Up to three video channels 

can be transported through the Optocore network depending on configuration. 

Ethernet Ports 

DD32R-FX  supports  Optocore  and  SANE  Ethernet  transport.  Two  LAN  ports  interface  with  all  other  LAN  and 
SANE/LAN ports in the Optocore and SANE Network creating a large unmanaged virtual 100Mbit Ethernet switch. 

Please note:

 

DD32R-FX principal AES/EBU ports are NOT equipped with Sample Rate Converters, 

Every 3

rd

 party device must be locked either to the Word Clock embedded in AES3 

frame or to the External Word Clock output of DD32R-FX

 

Содержание DD32R-FX

Страница 1: ...and SANE Operating Manual Rev 2 4 Operating Manual for OPTOCORE DD32R FX AES EBU I O SANE VIDEO DATA MODULE WITH ETHERNET Optical Digital Network Device Copyright 2020 All rights reserved OPTOCORE GmbH Alte Allee 28 81245 Munich Germany ...

Страница 2: ...Page intentionally left blank ...

Страница 3: ... way Pay special attention to plugs and sockets of the device Never switch on power amplifiers before the complete system is stable and the level meters of the OPTOCORE CONTROL software indicate a normal level Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plu...

Страница 4: ...or audio video and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation openings Install the device in accordance with the opera...

Страница 5: ... overload Lightning For additional protection of this device during lightning storms or when it is left unattended and unused for a long period of time disconnect the power cord This will prevent damage to the device due to lightning and power line surges Disconnection from the mains power supply is only possible by disconnecting the power plug from the mains socket Eye Safety This product is a La...

Страница 6: ...jury and serious damage to the device Any mounting of the device should follow the manufacturer s instructions and should use mounting accessories recommended by the manufacturer of the device Servicing Do not attempt to service this device yourself The device contains no user serviceable parts components or controls The operation of an opened device is not permitted Such operation can lead to dam...

Страница 7: ...ble protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which cas...

Страница 8: ...Page intentionally left blank ...

Страница 9: ...Ethernet Ports 15 Power Supply 16 Transmission Delay 16 Control 16 DD32R FX in Network Applications 16 Third party control 16 Optocore bandwidth allocation 17 SANE bandwidth allocation 17 Connectors and Cables 18 Optical Connection 18 Principal and Auxiliary Ports 18 SANE Ports 18 USB Connection 18 Word Clock Connection 18 Video Connection 18 Mains Connection 18 Hardware Connection 19 Example 1 19...

Страница 10: ... build the network exactly fitting the applications needs For example in combination with a X6R FX on Stage it is the perfect interface to a digital console at FOH A DD32R FX on stage can be used as an interface to all external microphone preamps with AES EBU outputs With Yamaha and Optocore microphone preamps the DD32R FX enables the gain control of the preamps on stage from a Yamaha digital cons...

Страница 11: ...d controls needed to operate the system including naming channels setting gains and phantom power routing as well as recall and capture of partial or full system configurations The software can be operated offline as well as online with level meters for all channels on the network The LEDs on the front panel of the DD32R FX units allow an instant overview regarding the status of each port ...

Страница 12: ...L1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the Word Clock Master unit OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Display Indicat...

Страница 13: ...r panel S2 Ethernet communication is established via SANE 2 rear panel UP There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel Sample Rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Страница 14: ...U or data transmission POWER 2 Mains input for power supply 2 100 240 V POWER 1 Mains input for power supply 1 100 240 V SANE 1 SANE RJ 45 interface for data transmission 100 Mbit Ethernet SANE 2 SANE RJ 45 interface for data transmission 100 Mbit Ethernet LINK 1 Full duplex full bandwidth LC type optical interface for Optocore transmission SFP multimode transceiver included singlemode transiver o...

Страница 15: ...ices A wide range of bi directional and unidirectional standards can be connected to the ports such as RS485 CAN Bus bi directional requires special firmware version or RS422 DMX and MIDI unidirectional The ports automatically sense whether they are sending or receiving control data The ports and their destinations are configured in the OPTOCORE CONTROL software Word Clock Devices with Optocore SA...

Страница 16: ... The system can be configured and controlled centrally over the Optocore network with the exception of the initial configuration of the unique identifier ID of the device The OPTOCORE CONTROL software is capable of running multiple instances on the same PC or by using the OPTOCORE CONTROL software s Client Server mode DD32R FX in Network Applications The monitoring and operational facilities are o...

Страница 17: ...nels Ethernet 100 MBit Fast Ethernet If the network is used for the transport of Ethernet compatible data the capacity is reduced to one CVBS video channel plus 100 Mbps Fast Ethernet SANE bandwidth allocation The standard bandwidth allocation of a SANE link is as follows Audio 64 Channels 48 KHz Ethernet 100 MBit Fast Ethernet Please note Optocore R Series devices equipped with 2Gbit fibre transc...

Страница 18: ...le Cat 5 Cat 5e Cat 6 terminated with RJ 45 connectors SANE utilizes all four pairs of the Cat 5 cable two pairs for standard Ethernet transmission and two pairs for the SANE synchronous audio transport A SANE cable shall not exceed a total cable distance of 100 m RS232 Connection Use a standard shielded RS232 cable Connector Hood Quality Locking screws for D Sub connectors should be compatible wi...

Страница 19: ...8 inputs and 8 outputs each which transmit four AES EBU 8 audio channels outputs and receives four AES EBU inputs The configuration of the ports as inputs and or outputs and the routing is carried out with OPTOCORE CONTROL software The control data is transmitted via the AUX pins in the BI B cables the control of the preamps by software or from the console is possible without any further wiring Fo...

Страница 20: ...s each two X6R TP 8MI 8LO units with one input and one output card each and one DD32R FX Fig 2 Connection of four X6R units and one DD32R In this example Ports A and B of the DD32R FX are outputs sending their signals to first two cards installed in console s slot Ports C and D are connected to the third card with 8 inputs and 8 outputs each Each of these ports transmits four AES EBU 8 audio chann...

Страница 21: ... Auxiliary Ports 4 x RS485 Channel RS485 GND Please assure correct polarity and at both sides devices when connecting external equipment to the RS485 ports 1 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 fe...

Страница 22: ...vices when connecting external equipment to the RS485 ports 1 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out USB Port Channel USB GND USB device connecto...

Страница 23: ... level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s SANE LAN Convention Audio TIA 568A B Optocore 200 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s Optical Connection Complies with 21 CFR 1040 10 and 1040 11 Power supply Type Switch mode univers...

Страница 24: ... panel width 483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight 2 7 kg 4 41 lbs Please note Modifications that serve the purpose of technical improvement may be carried out without prior notification ...

Страница 25: ...ring a problem with an OPTOCORE device you should contact either Optocore directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to OPTOCORE OPTOCORE will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest authorised ...

Страница 26: ...d your purchase order cannot be listed above Please note that due to the Ecology reason standard shipment does not contain printed copy of User Manual All latest OPTOCORE user manuals can be downloaded from the website http www optocore com index php support downloads Printed version of User Manual is available on a special demand Please contact support optocore com if printed version is required ...

Отзывы: