background image

 

 

 

DD32R-FX

 

10 / 26 

rev. 2.4

 

Device Description 

Congratulations on your purchase of a DD32R-FX Digital I/O Module for Optocore and SANE with video, Ethernet 
and data interfaces. The DD32R-FX manual will quickly demonstrate its advantages and help to ease your day-to-
day workload in a professional audio visual environment. 

The DD32R-FX is a digital I/O unit and interface to the OPTOCORE

®

 and SANE

®

 DIGITAL NETWORK SYSTEM. 

It offers four principal ports for connection and transport of a total of 32 AES/EBU digital audio pairs, which equals 
64  mono  channels.  These  ports  are  user  defined  as  inputs  or  outputs  in  groups  of  four.  Device  can  operate  in 
sample rates up to 192 kHz (sample rates above 96 kHz are available upon request).  

Redundant fibre connections can be established using the two provided SFP based LC multimode or singlemode 
optical  LINK-interfaces.  The  dual  redundant  ring  structure  provides  maximum  safety  in  a  network  with  an 
outstanding  low  latency.  It  facilitates  the  use  of  the  advantages  of  fibre  optical  transmission  in  all  sorts  of 
temporary  and  permanent  applications,  especially  when  long  distance  connections  and  high-quality  audio  are 
required. 

The DD32R-FX enables to connect to the SANE network via RJ45 ports. It is possible to use SANE as a Cat5 
based cost-efficient extension to the optical core system. SANE ports may be used as point-to-point MADI over 
Cat5 or as a bridge interface between SANE and OPTOCORE, providing up to 128 input and 128 output channels 
additionally to the principal AES/EBU ports. 

The  DD2FR-FX  provides  both  word  clock  input  and  output.  It  includes  also  bi-directional  composite  video 
interfaces. Additionally four RS485 ports allow the transport of a wide range of standards such as RS422, DMX, 
MIDI, and CAN-Bus (bi-directional, requires special firmware version). In addition to the audio signals, video and 
data  signals  are  transmitted  through  the  common  fibre  connection.  The  dual

 

power  supply  unit,  with  automatic 

switchover,  permits  a  redundant  power  supply  and  safeguards  against  malfunctions  in  the  event  of  a  power 
supply failure.  

In  combination  with  the  other  Optocore  devices  DD32R-FX  offers  a  great  flexibility  to  build  the  network  exactly 
fitting the applications’ needs. For example, in combination with a X6R-FX on Stage it is the perfect interface to a 
digital console at FOH. A DD32R-FX on stage can be used as an interface to all external microphone preamps 
with AES/EBU outputs. With Yamaha and Optocore microphone preamps the DD32R-FX enables the gain control 
of the preamps on stage from a Yamaha digital console at FOH. The DD32R-FX is not only an audio interface, 
but also a video and data interface for a broad range of control data standards. If analogue inputs and outputs are 
needed  the  DD32R-FX  serves  as  the  I/O  unit  for  the  converter  units  of  the  X6R/V3R  or  older  X6P-series. 
Networks with several DD32R-FX and other Optocore or SANE devices allow the transport of a huge amount of 
digital  data,  e.g.  7686  audio  channels  with  a  sample  rate  of  48 kHz,  32  RS485  channels  and  three  video 
channels, 100MBit Ethernet. Depending on the fiber optic transceivers, distances from 700 m up to 70 km can be 
covered (100m by Cat5 SANE). 

The  DD32R-FX  and  X6R/V3R-TP  can  be  used  together  in  a  SANE  CAT5  Network  (64  audio  channels  + 
Ethernet). Combinations of SANE and OPTOCORE

®

 OPTICAL DIGITAL NETWORK SYSTEM (up to 1024  input 

channels)  can  be  made  with  the  DD32R-FX  and  other  Revolution  FX  devices  to  exchange  audio  channels, 
Ethernet  and  Gain  Control.  All  parameters  on  the  I/O  Module  can  be  controlled  and  monitored  with  the  same 
software  application  as  all  other  Optocore  devices:  OPTOCORE  CONTROL  software.  They  allow  for  the 
distribution  of  various  channels  of  I/O  at  the  different  locations  throughout  your  digital  Optocore  and/or  SANE 
network. 

The Word Clock IN and OUT connections enable the synchronisation of the units to an external source and are 
used to pass the word clock from one unit to the next. For stand-alone applications, the devices are equipped with 
an internal word clock generator. 

The DD32R-FX units can be operated and controlled via the OPTOCORE network with OPTOCORE CONTROL 
software without the need for any external data cable. For control the USB, RS232 or LAN ports on the front / rear 
panels can be used. 

All  Optocore  devices  are  designed  and  built  using  the  latest  programmable  microprocessors  and  FPGA  (field 
programmable gate array) logic circuitry. This allows the devices internal logic to be updated, in the field, ensuring 
a continual state-of-the-art device. 

Содержание DD32R-FX

Страница 1: ...and SANE Operating Manual Rev 2 4 Operating Manual for OPTOCORE DD32R FX AES EBU I O SANE VIDEO DATA MODULE WITH ETHERNET Optical Digital Network Device Copyright 2020 All rights reserved OPTOCORE GmbH Alte Allee 28 81245 Munich Germany ...

Страница 2: ...Page intentionally left blank ...

Страница 3: ... way Pay special attention to plugs and sockets of the device Never switch on power amplifiers before the complete system is stable and the level meters of the OPTOCORE CONTROL software indicate a normal level Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plu...

Страница 4: ...or audio video and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation openings Install the device in accordance with the opera...

Страница 5: ... overload Lightning For additional protection of this device during lightning storms or when it is left unattended and unused for a long period of time disconnect the power cord This will prevent damage to the device due to lightning and power line surges Disconnection from the mains power supply is only possible by disconnecting the power plug from the mains socket Eye Safety This product is a La...

Страница 6: ...jury and serious damage to the device Any mounting of the device should follow the manufacturer s instructions and should use mounting accessories recommended by the manufacturer of the device Servicing Do not attempt to service this device yourself The device contains no user serviceable parts components or controls The operation of an opened device is not permitted Such operation can lead to dam...

Страница 7: ...ble protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which cas...

Страница 8: ...Page intentionally left blank ...

Страница 9: ...Ethernet Ports 15 Power Supply 16 Transmission Delay 16 Control 16 DD32R FX in Network Applications 16 Third party control 16 Optocore bandwidth allocation 17 SANE bandwidth allocation 17 Connectors and Cables 18 Optical Connection 18 Principal and Auxiliary Ports 18 SANE Ports 18 USB Connection 18 Word Clock Connection 18 Video Connection 18 Mains Connection 18 Hardware Connection 19 Example 1 19...

Страница 10: ... build the network exactly fitting the applications needs For example in combination with a X6R FX on Stage it is the perfect interface to a digital console at FOH A DD32R FX on stage can be used as an interface to all external microphone preamps with AES EBU outputs With Yamaha and Optocore microphone preamps the DD32R FX enables the gain control of the preamps on stage from a Yamaha digital cons...

Страница 11: ...d controls needed to operate the system including naming channels setting gains and phantom power routing as well as recall and capture of partial or full system configurations The software can be operated offline as well as online with level meters for all channels on the network The LEDs on the front panel of the DD32R FX units allow an instant overview regarding the status of each port ...

Страница 12: ...L1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the Word Clock Master unit OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Display Indicat...

Страница 13: ...r panel S2 Ethernet communication is established via SANE 2 rear panel UP There is other device with physical Ethernet port enabled on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel Sample Rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Страница 14: ...U or data transmission POWER 2 Mains input for power supply 2 100 240 V POWER 1 Mains input for power supply 1 100 240 V SANE 1 SANE RJ 45 interface for data transmission 100 Mbit Ethernet SANE 2 SANE RJ 45 interface for data transmission 100 Mbit Ethernet LINK 1 Full duplex full bandwidth LC type optical interface for Optocore transmission SFP multimode transceiver included singlemode transiver o...

Страница 15: ...ices A wide range of bi directional and unidirectional standards can be connected to the ports such as RS485 CAN Bus bi directional requires special firmware version or RS422 DMX and MIDI unidirectional The ports automatically sense whether they are sending or receiving control data The ports and their destinations are configured in the OPTOCORE CONTROL software Word Clock Devices with Optocore SA...

Страница 16: ... The system can be configured and controlled centrally over the Optocore network with the exception of the initial configuration of the unique identifier ID of the device The OPTOCORE CONTROL software is capable of running multiple instances on the same PC or by using the OPTOCORE CONTROL software s Client Server mode DD32R FX in Network Applications The monitoring and operational facilities are o...

Страница 17: ...nels Ethernet 100 MBit Fast Ethernet If the network is used for the transport of Ethernet compatible data the capacity is reduced to one CVBS video channel plus 100 Mbps Fast Ethernet SANE bandwidth allocation The standard bandwidth allocation of a SANE link is as follows Audio 64 Channels 48 KHz Ethernet 100 MBit Fast Ethernet Please note Optocore R Series devices equipped with 2Gbit fibre transc...

Страница 18: ...le Cat 5 Cat 5e Cat 6 terminated with RJ 45 connectors SANE utilizes all four pairs of the Cat 5 cable two pairs for standard Ethernet transmission and two pairs for the SANE synchronous audio transport A SANE cable shall not exceed a total cable distance of 100 m RS232 Connection Use a standard shielded RS232 cable Connector Hood Quality Locking screws for D Sub connectors should be compatible wi...

Страница 19: ...8 inputs and 8 outputs each which transmit four AES EBU 8 audio channels outputs and receives four AES EBU inputs The configuration of the ports as inputs and or outputs and the routing is carried out with OPTOCORE CONTROL software The control data is transmitted via the AUX pins in the BI B cables the control of the preamps by software or from the console is possible without any further wiring Fo...

Страница 20: ...s each two X6R TP 8MI 8LO units with one input and one output card each and one DD32R FX Fig 2 Connection of four X6R units and one DD32R In this example Ports A and B of the DD32R FX are outputs sending their signals to first two cards installed in console s slot Ports C and D are connected to the third card with 8 inputs and 8 outputs each Each of these ports transmits four AES EBU 8 audio chann...

Страница 21: ... Auxiliary Ports 4 x RS485 Channel RS485 GND Please assure correct polarity and at both sides devices when connecting external equipment to the RS485 ports 1 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 fe...

Страница 22: ...vices when connecting external equipment to the RS485 ports 1 2 3 4 Pin 1 2 3 4 5 6 7 8 9 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out USB Port Channel USB GND USB device connecto...

Страница 23: ... level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s SANE LAN Convention Audio TIA 568A B Optocore 200 Mbit s LAN TIA 568A B IEEE 802 3 10 100 Mbit s Optical Connection Complies with 21 CFR 1040 10 and 1040 11 Power supply Type Switch mode univers...

Страница 24: ... panel width 483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight 2 7 kg 4 41 lbs Please note Modifications that serve the purpose of technical improvement may be carried out without prior notification ...

Страница 25: ...ring a problem with an OPTOCORE device you should contact either Optocore directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to OPTOCORE OPTOCORE will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest authorised ...

Страница 26: ...d your purchase order cannot be listed above Please note that due to the Ecology reason standard shipment does not contain printed copy of User Manual All latest OPTOCORE user manuals can be downloaded from the website http www optocore com index php support downloads Printed version of User Manual is available on a special demand Please contact support optocore com if printed version is required ...

Отзывы: