background image

LTCLHP

 | instruction manual

5

v 1.1

black

 cable to 

ground

blue

 cable (LED anode) to your power supply 

or external strobe controller

Make sure not to exceed 

LEDs maximum rates to avoid 

electrical shorts.

2.1.2 Direct LED control usage option

Both continuous and pulsed mode are allowed; the built-in electronics can be bypassed in 

order to drive the LED directly for use in continuous or pulsed mode. When bypassed, built-

in electronics behaves as an open circuit allowing direct control of the LED source.  Please 

note that in such case light intensity adjustment is not possible though the built-in multi-turn 

trimmer. 

Connection

Connect the black and blue cables as shown below (remove the LED anode protective cover):

2.2 LED source axial position

LED axial position is an important operational parameter that must be correctly set to 

obtain optimal illumination homogeneity. LED axial position is adjusted at factory by placing/

removing internal or external spacers of various thicknesses. 

Each LTCLHPxxx illuminator is configured by default with the number and type of spacers 

needed to achieve the best illumination homogeneity with its corresponding TC

23

xxx 

telecentric lens model. 

The number and type of spacers needed to achieve the optimal light homogeneity can be 

different  when  LTCLHPxxx  is  used  in  combination  with  TC

13

xxx, TC

12

xxx or telecentric 

lenses designed for other sensor sizes.

Содержание LTCLHP series

Страница 1: ...LTCLHP series Telecentric HP illuminators Instructions manual v 1 1 www opto engineering com...

Страница 2: ...of contents 1 Product overview pag 3 2 Instructions for use pag 4 2 1 Operation options pag 4 2 2 LED source axial position pag 5 2 3 How to replace the LTSCHP module pag 6 2 4 How to replace the LED...

Страница 3: ...telecentric lenses LTCLHP telecentric illuminators offer higher edge contrast when compared to diffused back light illuminators and therefore higher measurement accuracy This type of illumination is...

Страница 4: ...nics Only continuous mode constant current is allowed Connection Connect the black and brown cables to your 12 24 V power supply Light intensity adjustment The built in multi turn trimmer allows to co...

Страница 5: ...multi turn trimmer Connection Connect the black and blue cables as shown below remove the LED anode protective cover 2 2 LED source axial position LED axial position is an important operational parame...

Страница 6: ...operational parameter make sure to follow the instructions in the next section to obtain optimal illumination homogeneity LTSCHP module LED centering tool to easily position and center LED1W x light s...

Страница 7: ...1 4 LTCLHP056 R red 630 nm 2 0 2 LTCLHP056 G green 520 nm 0 5 1 LTCLHP056 B blue 460 nm 1 0 1 4 LTCLHP056 W white 0 5 1 1 4 LTCLHP064 R red 630 nm 2 0 2 LTCLHP064 G green 520 nm 0 0 LTCLHP064 B blue...

Страница 8: ...thermal energy across the metal to metal interface we suggest to use grease with thermal conductivity greater than 0 765W mK Use the screws with the appropriate length according to the presence of int...

Страница 9: ...e 2 4 1 Replacement instructions Follow these steps to properly replace LED1W source 1 5 2 6 3 4 Turn off LTCLHP and disconnect the power cable Unscrew the LTSCHP module from the LTCLHP illuminator Re...

Страница 10: ...11 02 Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement CEI EN 61000 4 3 2007 04 CEI EN 61000 4 3 A1 2009 01...

Страница 11: ...E phone 49 0 89 18930918 de opto engineering com Opto Engineering USA 11261 Richmond Ave Ste G 108 Houston TX 77082 phone 1 832 2129391 us opto engineering com ASIA Opto Engineering Europe headquarter...

Отзывы: