I. Introduction 

Thank you for choosing Opto-Edu A33.1502 Biological Microscope.    To ensure safety and obtain optimum performance 

and familiarize yourself with the use of this microscope, we recommend that you read this manual thoroughly before 

operating the microscope. Retain this instruction manual in an easily accessible place near the microscope for further 

reference.

 

 

II

.

                   

Caution 

 

Attention 

A33.1502 Biological Microscope can only be used inside the room. Place microscope on a stable plane and keep it in 

balance. Power line must be retained in an easily accessible place to prevent any unnecessary accident. 

 

Working Environment 

As microscope is a precision instrument, improper using will make it unworkable or reduce its precision. 

1. 

Do not expose the microscope in the sun directly 

2. 

Temperature range is +10

- +40

and the max. humidity is 85% 

3. 

Avoid high temperature and humidification. Otherwise there will be fog or mold on the lens. 

4. 

Avoid violent vibration as the vibration will reduce the images quality. 

5.     Do not place microscope in moist room to avoid short circuit. Please turn off the power supply as soon as water drop 

in the microscope. If there are other things unsafe come into the microscope which may cause short circuit too, please 

stop using and contact with manufacturer 

 

Non-designated Application 

1. 

Improper operation & usage may 

cause damage to both instrument & 

users. Please read instruction 

manual carefully before using the 

instrument. 

2. 

Pay attention to the voltage. Do not 

use other kinds of power line unless 

there is specific description. Do not 

take the microscope apart. 

 

Instrument & accessories 

described in this manual have 

passed the safety & potential 

risk test. 

 

III. Structure 

 

See Picture

 

 

Содержание A33.1502

Страница 1: ...sale cnoec com To ensure the safety and obtain satisfactory performance please study this instruction manual thoroughly before start to use your instrument A33 1502 9 7 LCD Digital Microscope 5 0M An...

Страница 2: ...n 1 Do not expose the microscope in the sun directly 2 Temperature range is 10 40 and the max humidity is 85 3 Avoid high temperature and humidification Otherwise there will be fog or mold on the lens...

Страница 3: ...on 9 7 LCD Pad Digital Camera A59 3520 LCD 9 7 HD IPS Touch Screen With Backlight Camera 5 0M 1 2 5 CMOS Digital Camera Resolution 2048x1536 15FPS Pixel 2 2umx2 2um Data Storage TF Card or Built in Me...

Страница 4: ...agm is designed configured on condenser Adjusting the iris diaphragm to match the different N A of different objectives 1 Open Close the iris diaphragm by adjusting knob 2 When the knob is on the righ...

Страница 5: ...e container Cleaning 1 Keep all the optics clean It is very important to maintain optical performance of the instrument 2 If dust or dirt is covered on the surface of the lens Have a try of air blower...

Страница 6: ...www optoedu com Page 6 of 15 sale cnoec com LCD Digital Camera A59 3520 Real Time Measurement Software for Android...

Страница 7: ...c 2 1 Camera parameter adjustment 2 2 Measurement 2 3 Image and video playback 2 4 Take pictures and record video 2 5 Setting 3 Capture and Playback Click Snap button to take a picture Select picture...

Страница 8: ...Once AWB Click icon to trigger once auto white balance Manual WB Manually adjust color temperature Color Adjustment Contrast Saturation sharpness and gamma of the image can be adjusted too Click the...

Страница 9: ...15 sale cnoec com Enter calibration mode Follow the Tips 1 Drag the yellow ruler let endpoints of the ruler close to physical ruler s scale We use the 0 01mm physical ruler each big grid is 10 m we p...

Страница 10: ...hysical length of the ruler that is 20 m 3 Click Calculate to calculate the calibration value for current objective and preview size and save to list 5 2 Measure Tool ICON Function Description point c...

Страница 11: ...notation on the image Option Change stroke width and color of rulers and the size and color of the text export Export the image with measurement rulers Delete Delete the selected ruler Delete Delete a...

Страница 12: ...application which used to process microscopic images on Android devices It depends on computer vision library Open CV Currently version 1 0 of Image provides functions like gray scale contrast binariz...

Страница 13: ...st contrast and brightness of the gray scale image increase the difference between the objects and background 6 1 4 Binarization With the binarization tool you can change the minimum and maximum value...

Страница 14: ...icle analysis tool First of all because some noise or dirty point was not clear by binarization You need set the range of particle s size Reduce the range of particle s size will make the result much...

Страница 15: ...oedu com Page 15 of 15 sale cnoec com Click Analyze Particles button to start analysis the result will show blow Click CSV button to export to data to report file the default path is mnt sdcard Image...

Отзывы: