background image

 

 

www.optoecu.com                                                                                                  3 / 15                                                                                  [email protected] 

 

INDEX

 

A) Application                                                                                                              P.1 
B) Principle                                                                                                               

   

P.1

 

C) Structure and Specification                                                                                P.1

 

1.  Eyepiece                                                                                                                P.1 
2.  Objective                                                                                                         

     

P.1 

3.  Mechanical Tube Length                                                                         

         

P.2 

4.  Conjugated Distance Between Object and Image                                      P.2 
5.  Viewing Heads and Microscope Models                                               

       

P.2 

6.  Nosepiece                                                                                                         

   

P.5 

7.  Mechanical Stage                                                                                                P.5 
8.  ABBE Condenser                                                                                                P.5 
9.  Focusing System                                                                                                P.5 
10. Illumination System                                                                                       

   

P.5

 

D) How to Use and Assemble                                                                                  P.6 
E) Trouble Shooting                                                                                             

     

P.7 

1.    Troubles in Operating                                                                           

 

 

       

P.7 

2.    Troubles in Optical System                                                                     

       

P.8 

3.    Troubles in Electric System                                                                            P.8 

F) Maintenance and Care of Your Microscope                                                    P.9 
G) Microscope with CCD Camera                                                                     

     

P.9

 

H) Microscope with Camera                                                                               

     

P.10

 

I) Microscope with Electron Eyepiece                                                             

     

P.11 

J) A31.1303-1.3M Digital Microscope                                                         

           

P.12 

Appendix A: Eyepieces and Objectives for Option                                        P.12 
Appendix B: Digital Camera Head                                                               

       

P.13 

 

 

 

 

 

 

 

 

 

 

 

 

 

This manual is suited for following models A11.1303 

Содержание A11.1303 Series

Страница 1: ...www optoecu com 1 15 sale cnoec com A11 1303 Student Biological Microscope Instruction Manual...

Страница 2: ...oubleshoot them by yourself according the manual please contact us or our representative in you area 3 Safety Before change a bulb or need to open the base ensure that the microscope has been disconne...

Страница 3: ...Focusing System P 5 10 Illumination System P 5 D How to Use and Assemble P 6 E Trouble Shooting P 7 1 Troubles in Operating P 7 2 Troubles in Optical System P 8 3 Troubles in Electric System P 8 F Mai...

Страница 4: ...F20X or Huygenian eyepieces as 5X 6X 10X 12 5X 15X 16X The specifications of WF10X are showed as following P 1 a b e c d f Fig 1 The Principle Draft In this microscope the standard outfit of the objec...

Страница 5: ...Down 17 Swtich 18 Plate for Adjusting Brightness 16 Screw for Bulb Changing 8 Screw for Centring the Condenser Fig 2 The Structure Draft 3 Mechanical tube length 160mm 4 Conjugated distance between o...

Страница 6: ...process software help you to preview measure compare count save and delete Connecting the CCD camera with the TV the micro image will be showed for teaching V type dual observing head 360 rotatable On...

Страница 7: ...screen User friendly sophisticated micro image process software help you to preview measure compare count save and delete 3 Insert the CCD camera with the CCD Linker Connecting the CCD camera with th...

Страница 8: ...the knob 25 built in rack and pinion mechanical system controls the condenser up or down Usually raise the condenser higher when 100X or 40X objective is used Down the condenser lower when 10X or 4X...

Страница 9: ...b D How to use and assemble 1 Unpack the microscope and its parts carefully Check and sort out all parts according to the packing list 2 For the convenience of packaging and delivering the components...

Страница 10: ...e 4X and 10X objectives can never come into contacting with your micro slide specimen because of our built in stop The 40X and 100X objectives may occasionally touch the micro slide specimen But becau...

Страница 11: ...ld is dark Image moves while focusing The specimen is not caught stably by the clamp The image is yellow Blue filter is not used The viewing field is too dark P 8 Remove the dust and dirt There are du...

Страница 12: ...to choose model XSP21 01V or XSP21 01T microscope 1 See Fig 4 and connect the CCD camera with the microscope as following steps 1 Take the plastic dust cover off from the viewing head and screw the v...

Страница 13: ...nd its PL pilot lamp is lighting 3 Whether the TV is turned on the mode AV or VIDEO 4 Whether the rod on the right of trinocular head is pushed out 5 Whether the microscope is focused correctly At thi...

Страница 14: ...can observe by using common eyepiece at the same time of showing the micro image in the PC screen The electron eyepiece is also used in model XSP21 01M or XSP21 01B microscope See Fig 6 and connect th...

Страница 15: ...een as the following ways 1 Turn the plate 19 to make the illuminator darker 2 Turn the plate 10 to make the diameter of the iris diaphragm smaller 3 Rotate the knob 23 to lower the ABBE condenser Whe...