background image

 

 

www.optoecu.com                                                                                                  2 / 15                                                                                  [email protected] 

 
Dear Sir or Madam: 
 

Thank  you  for  using  our  A11.1303  series  microscopes.  As  one  of  the  professional 

designers, manufacturers and distributors for optical instruments in China, since 1978, we 
have been working for supplying the new or old customers worldwide with high-quality and 
low-cost  products.

 

Being  the  newest  product,  we  wish  that  our  products  could  bring  you 

success  and  satisfaction.  We  enjoy  offering  you  the  most  suitable  products  and  the  best 
service. 

 
This  manual  gives  a  minute  description  of  the  structure,  principle,  configuration, 

operating  guide,  troubleshooting

maintenance  and  some  attention  for  A11.1303  series 

biological microscope. Please read it carefully before you use, and keep it for long time. 

 
In particular, the following notes must be understood thoroughly and obeyed strictly: 
 
1. Permitted use: 

This microscope is just only used for biological microscopy observation. 

Don’t 

misuse it for other purpose. 

 

2. No dismantle the equipment: 

Unless you are a microscopic expert, or there is a special guide about doing so in the 

manual, p

lease don’t dismantle your microscope. Otherwise, it will damage the 

microscope seriously, and reduce greatly its accuracy and using-life. When you identify 
some troubles, and can

’t troubleshoot them by yourself according the manual, please 

contact us or our representative in you area. 

 

3. Safety 

----Before change a bulb, or need to open the base, ensure that the microscope has 

been disconnected with the power source. The new bulb must be the same 
specifications as the old one. 

----When the illuminator is halogen lamp or incandescent lamp, the base near the 

lighting source may be very hot. Don

’t worry about it, but it must be treated carefully. 

Please take the combustible material (such as gasoline, paper, plastic and cloth) far 
away from the microscope. 

----When change incandescent bulb or halogen bulb, wait until it is cool enough, 

otherwise the hot bulb will burn your fingers. 
 
4. Use the correct power supply voltage 

The power supply voltage must be fitted to the microscope; otherwise it will damage 

the circuit and bulb, even lead to insecurity. 

 

5. Protecting optical parts 

Never try to contact directly the optical surface of objectives, eyepieces and other 

optical parts with your finger. Fingerprints will seriously affect your observation results. 

 

6. Don

’t leave any dust and fingerprints on the bulb, otherwise it may affect its life and 

illuminating efficiency. 
 
7. Working surroundings requirements 

Room temperature: 0°C-40°C 
The highest relative humidity: 85% 
High temperature and humidity can cause mildew and damage the instrument. 
 

8.  Microscope  is  a  precision  instrument,  soft  and  gentle  operation  is  necessary.  Any 
rude action or hard shake may damage it. 

 

Содержание A11.1303 Series

Страница 1: ...www optoecu com 1 15 sale cnoec com A11 1303 Student Biological Microscope Instruction Manual...

Страница 2: ...oubleshoot them by yourself according the manual please contact us or our representative in you area 3 Safety Before change a bulb or need to open the base ensure that the microscope has been disconne...

Страница 3: ...Focusing System P 5 10 Illumination System P 5 D How to Use and Assemble P 6 E Trouble Shooting P 7 1 Troubles in Operating P 7 2 Troubles in Optical System P 8 3 Troubles in Electric System P 8 F Mai...

Страница 4: ...F20X or Huygenian eyepieces as 5X 6X 10X 12 5X 15X 16X The specifications of WF10X are showed as following P 1 a b e c d f Fig 1 The Principle Draft In this microscope the standard outfit of the objec...

Страница 5: ...Down 17 Swtich 18 Plate for Adjusting Brightness 16 Screw for Bulb Changing 8 Screw for Centring the Condenser Fig 2 The Structure Draft 3 Mechanical tube length 160mm 4 Conjugated distance between o...

Страница 6: ...process software help you to preview measure compare count save and delete Connecting the CCD camera with the TV the micro image will be showed for teaching V type dual observing head 360 rotatable On...

Страница 7: ...screen User friendly sophisticated micro image process software help you to preview measure compare count save and delete 3 Insert the CCD camera with the CCD Linker Connecting the CCD camera with th...

Страница 8: ...the knob 25 built in rack and pinion mechanical system controls the condenser up or down Usually raise the condenser higher when 100X or 40X objective is used Down the condenser lower when 10X or 4X...

Страница 9: ...b D How to use and assemble 1 Unpack the microscope and its parts carefully Check and sort out all parts according to the packing list 2 For the convenience of packaging and delivering the components...

Страница 10: ...e 4X and 10X objectives can never come into contacting with your micro slide specimen because of our built in stop The 40X and 100X objectives may occasionally touch the micro slide specimen But becau...

Страница 11: ...ld is dark Image moves while focusing The specimen is not caught stably by the clamp The image is yellow Blue filter is not used The viewing field is too dark P 8 Remove the dust and dirt There are du...

Страница 12: ...to choose model XSP21 01V or XSP21 01T microscope 1 See Fig 4 and connect the CCD camera with the microscope as following steps 1 Take the plastic dust cover off from the viewing head and screw the v...

Страница 13: ...nd its PL pilot lamp is lighting 3 Whether the TV is turned on the mode AV or VIDEO 4 Whether the rod on the right of trinocular head is pushed out 5 Whether the microscope is focused correctly At thi...

Страница 14: ...can observe by using common eyepiece at the same time of showing the micro image in the PC screen The electron eyepiece is also used in model XSP21 01M or XSP21 01B microscope See Fig 6 and connect th...

Страница 15: ...een as the following ways 1 Turn the plate 19 to make the illuminator darker 2 Turn the plate 10 to make the diameter of the iris diaphragm smaller 3 Rotate the knob 23 to lower the ABBE condenser Whe...

Отзывы: