background image

 

 

UMX-CC version 1.0 

13

 

AUDIO IP MANAGEMENT CARD 

FOR UMX-02/0 MODULAR MATRIX 

UMX-CC 

R&D Department 

NOTE: If one UMX-CC card is added or its configuration is modified, it is necessary to send configurations to all 
the Optimax equipments in the installation. 

3.5.

 

Connecting the equipment in the installation structure 

When equipment units are added to the installation, they appear in the structure with their name in red, 
preceded by the “disconnection” icon. While their status is shown as disconnected, these equipment units 
are not operative. 

To connect the equipment, proceed as follows: 

1.

 

In the installation structure, right click with the mouse on the 
disconnected equipment unit. 

2.

 

Click on 

Connect Equipment

. The connection icon appears and the 

name of the equipment unit is shown in green. 

 

 

3.6.

 

Sending configurations to a UMX-CC card 

1.

 

Before sending configurations to any equipment unit, it is advisable to save the configuration. To do 

this, from the P.A. Manager software installation screen, open the 

File

 menu and select 

Save

1.

 

On the installation tree, right click with the mouse on the name of the UMX-CC card and select the 

option 

Send configurations

.

 

2.

 

A progress bar appears. Upon completion, click on 

OK

 

 

4.

 

 CONFIGURATION OF THE UNIT IP ADDRESS BY 

SOFTWARE 

It is possible to change the IP address of the UMX-CC card by 
means  of  the  DIP  switches  situated  on  the  underside  of  the 
unit or remotely through the software. 
 
To make the change by software, from the installation screen 
of the P.A. Manager software right click with the mouse on the 

name of the unit and select the option 

Web Connection (1).

 

 
If  the  PC  is  remote  with  respect  to  the  installation,  open  the 
Internet  browser  and  enter  the  IP  of  the  unit  in  the  address 
bar  (for  example:  http://10.1.1.2).  This  IP  address  is  the 
address  configured  through  the  IP  configuration  DIP  switches 
of the UMX-CC card. 

 
 
 
 

(1) 

 

  =  Equipment disconnected 

 

  =  Equipment connected 

Содержание UMX-CC

Страница 1: ...9I021G 13 04 2011 ...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...and connections 9 3 3 Adding the card to the installation by means of the P A Manager software 9 3 4 Configuration of the parameters of the UMX CC card 10 3 5 Connecting the equipment in the installation structure 13 3 6 Sending configurations to a UMX CC card 13 4 CONFIGURATION OF THE UNIT IP ADDRESS BY SOFTWARE 13 5 NETWORK SPECIFICATIONS 15 6 TECHNICAL SPECIFICATIONS 17 7 SOFTWARE AND FIRMWARE ...

Страница 6: ...ipment operation by means of P A Manager software and or basic TELNET functions IP address configuration by means of DIP switches facilitating the replacement of equipment in an installation or remotely through software 2 ELEMENTS 1 CTRL OUT strip Not used 2 ETHERNET A connector RJ45 type connector Used for connection to the ETHERNET network Cat 5 STP cable must be used for its connection 3 ETHERN...

Страница 7: ...e card in a UMX 02 0 chassis its IP address must be configured For this purpose it has 4 internal DIP switches see Figure 2 The IP address of the card is configured by means of these 4 DIP switches This address identifies the card in the network and so each equipment unit must have a unique IP address An IP address is represented by means of a 32 bit binary number The IP addresses are expressed as...

Страница 8: ...UMX CC version 1 0 8 AUDIO IP MANAGEMENT CARD FOR UMX 02 0 MODULAR MATRIX UMX CC R D Department Table I Configuration of the IP address ...

Страница 9: ... of the P A Manager software To configure the card it is necessary to have a PC connected to the network that has the SCF 01 or SCM 01 P A Manager software 1 If the software is the SCM 01 start the application open the Options menu and select Installations administrator user level is required If the software is the SCF 01 start the application NB Prior to configuration of the parameters of the UMX...

Страница 10: ...stallation topology makes it necessary All the units with an IP connection in the installation must have the same IP multicast address 7 Multicast port Default setting 5000 Do not modify this field unless the installation topology makes it necessary All units with an IP connection in the installation must have the same multicast port 8 Send Heart Beat every n seconds Frequency with which the unit ...

Страница 11: ...on screen open the Options menu and select Multicast Configuration 2 A window with the configurations of the multicast group appears Double click on the data item that you wish to change 3 Modify the value and click on Accept 4 Confirm the change by clicking on Yes 5 Close the Multicast Configuration window by clicking on OK ATTENTION The values that are modified from the Multicast Configuration w...

Страница 12: ...ata may circulate freely across the network This function is performed by two applications one at a local level known as LCC which manages the digital channels at PA Area level and another known as GCC which manages the digital channels at a global level between different PA areas and or servers Each PA Area needs at least one LCC process on one of its equipment units If there is more than one PA ...

Страница 13: ...configurations to any equipment unit it is advisable to save the configuration To do this from the P A Manager software installation screen open the File menu and select Save 1 On the installation tree right click with the mouse on the name of the UMX CC card and select the option Send configurations 2 A progress bar appears Upon completion click on OK 4 CONFIGURATION OF THE UNIT IP ADDRESS BY SOF...

Страница 14: ...s follows 1 Enter the password in the Administrator Login section 2 contact technical staff at Optimus and they will provide you with this and click on Login 3 2 Open the Expert menu 4 and click on the Set IP address option 5 3 Write the new IP in the IP Address field 6 for example 10 1 1 100 and click on Save IP Address 7 ATENCIÓN Once the IP address of the unit has been changed it is necessary t...

Страница 15: ...le of the management data sent 1 Default multicast base addresses ports and configurations Broadcast address Broadcast port Initial configuration download 255 255 255 255 3333 Multicast address Multicast port Initial configuration download 239 5 5 5 8001 Multicast address Multicast port Others Control data 239 5 5 5 5000 Heart beat every 10 seconds Global audio channels 239 1 0 x 6000 x 8 simultan...

Страница 16: ...ulticast filtering IGMP v2 For large installations Multicast routing Spanning Tree Capacity to handle TOS Type Of Service 5 Certified hardware Large installations Nortel BayStack 470 Ethernet Routing Switch 3510 and higher Cisco 36XX or higher Alcatel Level 3 switches Medium sized installations NKF XSNET 1800 Hirschmann RS30 0802O6O6SDAEHH01 0 Small installations with a proprietary network Nortel ...

Страница 17: ... are valid for the following software and firmware versions or later versions Firmware UMX CC Update 2 6 19 P A Manager Software Version 2 6 Revision 4114 28490 Optimus Flasher Software Version 2 6 9 8 DOCUMENT VERSION TRACKING Reference system Type of Document Confidentiality N A Optimax Installation and operation guide Rev Date Modifications Content Written by 1 0 04 2011 First version R D Depar...

Страница 18: ...r use of the equipment including lack of maintenance 5 The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or purchase invoice Failure to produce the original invoice or the absence of a date on this Absence of the serial or batch number on the equipment 6 In the case of personal computers the guarantee will...

Отзывы: