Operation
Version 1.0.1 - 2020-08-18
21
Translation of original instruction
DP33
EN
D
P
33_G
B.
fm
4.2
Switching on the machine
Check that the emergency stop switch is not pressed or unlocked. Turn the emergency stop
switch to the right to unlock.
The protective cover of the V-belts must be closed.
Set all actuators to the neutral position and close the drill chuck protection.
Select the direction of rotation on 400V drills.
Press the "On" button.
4.3
Switching off the machine
CAUTION!
Only press the emergency-stop button in a genuine emergency. You should not use the
emergency stop button to stop the machine during normal operation.
Press the "Off" button.
Disconnect the power plug if the unit is not used for a longer period of time.
4.4
Resetting an emergency stop situation
Set on 400V machines the direction of rotation switch to the neutral position.
Unlock the emergency stop switch again.
4.5
Power failure, Restoring readiness for operation
Set on 400V machines the direction of rotation switch to the neutral position.
Actuate the push button "ON".
4.6
During work
WARNING!
Seizing of clothes and / or hair.
Make sure to wear well-fitting work during drilling work.
Do not use gloves.
If necessary, use a hairnet.
CAUTION!
Risk of impact by the spindle sleeve lever. Do not release the spindle sleeve lever when
repositioning the drilling spindle sleeve.
CAUTION!
Danger of crushing. Do not place your hand between the drilling head and the
spindlesleeve.
The spindle sleeve feed is done via the spindle sleeve lever. Make sure that the feed is
constant and not too fast. The spindle sleeve is returned to its initial position by the return
spring.
The smaller the bit the more easily it may break. In the case of deep drilling, remove the bit
from time to time to remove filings from the drill. Add a few drops of oil to reduce friction and
prolong the service life of the bit.