background image

6

STEP 1

Voltage 

Selection

24V

12V

  

  

  

Se

lect

2

1a

1b

LED #1a / 1b:

 

Confirms AC power supply to the charger and selected battery 

voltage.
Changing voltage selection: 

Disconnect charger from battery. Place and hold finger 

on Select-TOUCH sensor. The selected voltage LED brightens to confirm touch. (i.e. if 
‘12V’ was on, then ‘12V’ will brighten). 
After 3 seconds the voltage selection changes, then SAVE (#3), CHARGE (#4) and TEST 
(#6, 7, 8) LEDs flash twice to confirm selection is in memory. 
LED #1a => 12V
LED #1b => 24V
NOTE: Selection remains even if AC power is lost.

STEP 2

Protection

TEST

8

7

6

24V

12V

  

  

  

Se

lect

2

1a

5

1b

Charger will not proceed without user interaction.

LED #2 REVERSE POLARITY: 

Lights when the battery connections are 

incorrect. 

The charger is electronically protected so no damage will result, and the 

output will remain disabled until the connections are corrected.

VOLTAGE SAFETY CHECK:

 

12V (#1a) and 24V LEDs (#1b) alternate and green test LED (#6) lights. 

12V is selected and a battery with voltage exceeding 15V is connected. 

Connected battery may be 24V.
Action: Disconnect battery, select 24V.

24V (#1b) and 12V (#1a) alternate and red test LED (#8) lights. 

24V (#1b) selected and a battery with voltage below 18V is connected: 

The connected battery may be 12V or it may be a deep discharged 24V battery. 
Action: Physically check battery. If nominal voltage is 12V, disconnect battery and 
select 12V. 
If nominal voltage is 24V, hold finger on Select-TOUCH. After 5 seconds program will 
proceed to STEP 3. 

STEP 3

TEST 

before 

charge

TEST LEDs
6 : GREEN
7 : YELLOW
8 : RED

TEST

8

7

6

TEST LEDs #6/7/8 indicate the battery condition prior to charging. Consult the table  
below to match TEST LED indication to an estimated state of charge percentage 
(SOC%). 

During the test: 
STEP 6 OPTIMIZE minimum charge time is set according to the test result, varying 
between 10 minutes for a battery with 80% or higher state of charge to 120 minutes 
for a battery with 40% or less state of charge. 
Ambient temperature is measured to determine charge voltage parameters. 

Charging commences after 10 seconds. 

LED #8 (RED) flashing:

 Battery voltage is very low. Pulses are injected to check for a 

short circuit or connected circuitry drawing high current. Once the indication becomes 
steady for up to 10 seconds charging will commence. If not, disconnect the battery 
from connected circuitry and try again. 

STEP 4

SAVE

LED #3 : RED

3

The SAVE mode engages if the battery state of charge was less than 50% 

or the battery was diagnosed as sulphated (as tested in STEP 3).

Charge time: Minimum 15 minutes, maximum 2 hours. 
A recondition charge is applied; current is delivered in pulses to prepare the battery to 
accept normal charge. 

Содержание 7 Select

Страница 1: ...ic shock or fire 9 To reduce risk of electric shock unplug the charger from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk Clean only with slightly moist not wet cloth Do not use solvents 10 WARNING RISK OF EXPLOSIVE GASES a WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION...

Страница 2: ...off position and or remove AC cord from electrical outlet disconnect the battery clips then reconnect correctly according to the instructions below 15 FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR A BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Position AC and DC cords so as to reduce risk of damage by hood door or moving engine part b Stay cle...

Страница 3: ...ventual penetration of liquid into the electronic components connectors or plugs is not covered by warranty CONNECTING THE CHARGER TO THE BATTERY 1 Disconnect AC power supply before making or breaking DC battery connections 2 If charging a battery in the vehicle or craft with the battery clips before making connections first check that the battery clips can be safely and securely positioned clear ...

Страница 4: ...be 12V or it may be a deep discharged 24V battery Action Physically check battery If nominal voltage is 12V disconnect battery and select 12V If nominal voltage is 24V hold finger on Select TOUCH After 5 seconds program will proceed to STEP 3 STEP 3 TEST before charge TEST LEDs 6 GREEN 7 YELLOW 8 RED TEST 8 7 6 TEST LEDs 6 7 8 indicate the battery condition prior to charging Consult the table belo...

Страница 5: ...oltage Consult the EARLY WARNING OF BATTERY PROBLEMS table on page 2 to match TEST LED indication to an estimated state of charge percentage SOC More information is provided in the section NOTES ON TEST RESULTS STEP 8 OptiMATE smart MAINTAIN LED 6 7 8 ON TEST 8 7 6 For batteries with a good state of health LED 6 green will remain on Exception STD wet cell batteries with filler caps have a lower fu...

Страница 6: ...tery from the OptiMate After at least 48 hours reconnect and observe the result during the TEST BEFORE CHARGE MAINTAINING A BATTERY FOR EXTENDED PERIODS The OptiMate will maintain a battery whos basic condition is good for months at a time At least once every two weeks check that the connections between the charger and battery are secure and in the case of batteries with filler caps on each cell d...

Отзывы: