5. The blades do not close properly although the spade cylinders are fully extended.
-
Guides are worn and must be replaced.
-
Blades are bent and have to be adjusted.
6.
One function (any) does not work.
-
The electricity supply is interrupted. Check power circuit.
-
The magnet of the respective control valve is defect. Valve must be replaced.
-
The plunger of the control valve is seized, probably due to a dirt particle in the
hydraulic oil. Disassemble valve and clean.