background image

 

 

 

 

 

 

 
 
 

 

 
 
 
 
 

REDUNDANT POWER SUPPLY SYSTEM FOR 

NETGEAR® RPS CAPABLE ETHERNET SWITCHES 

 

 

 
 
 

M

ODEL 

N

O

. RPS5412 

Redundant Power Supply

 

 
 
 
 
 

Manual 

 

Revision B 

 

July 2014 

 
 
 
 
 
 
 
 

Optimal Power Supplies LLC 

www.optimal-power.com

 

 

 

Содержание RPS5412

Страница 1: ...i REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES MODEL NO RPS5412 Redundant Power Supply Manual Revision B July 2014 Optimal Power Supplies LLC www optimal power com ...

Страница 2: ... document without notice WARRANTY 1 Optimal Power warrants its product models RPS5412 and RPSC5412 against defects in materials and workmanship for Three 3 year from date of delivery We will repair or replace parts which prove to be defective during the warranty period 2 Any defect discovered after the warranty period has expired will be deemed to be outside the coverage of the warranty as noted b...

Страница 3: ...l System Level Setup 5 3 Status Indicators and Back Panel Connections 6 3 1 Back Panel DC Power Connector 6 3 2 3 3 3 4 Front Panel Status Indicators Compatible NETGEAR Switch Model Number Table Model No RPSC5412 DC Connection Cable 6 6 7 4 Alarm Systems 8 4 1 Alarm Monitoring System 8 5 Installation and Maintenance 9 5 1 Installation 9 5 2 Maintenance Safety Instructions 11 5 3 Trouble Shooting I...

Страница 4: ...orking Applications Telecommunications and Fiber Optic Network Voice Data and Analog Communications Universities and Educational Facilities Instrumentation and Electronics Utility and Power Industries Data Acquisition Medical Military The RPS Power Series is a reliable efficient and inexpensive solution for all kind of AC to DC power supply applications Optimal Power RPS units are intended for pro...

Страница 5: ... 20 C to 85 C Cooling Forced Air Convection Cooling Overload Protection Auto Recovery Efficiency 80 90 Typical DC OK Status LED 1 4 Typical Safety Rating for Internal Power Supply Bricks Designed in full compliance with UL60950 CSA 22 2 No 234 EN60950 EMI EN55022 Class A EMS EN61000 4 2 3 4 5 6 8 11 Harmonics EN61000 3 2 Class D 1U Power Supply Shown above Model RPS5412 ...

Страница 6: ...urrent Typical 6A max Typical 9A max Output Power 300W 100W Input Voltage Universal 90VAC to 264VAC input Input Frequency 47Hz to 63Hz Input Current Approx continuous 5 Amperes NOTE The Model RPS5412 only provides up to 300W for Power Over Ethernet POE application If POE devices connected to the switch system need more than 300W then this device is not recommended Typical Safety Ratings for Intern...

Страница 7: ...4 Physical Dimensions 1U 1 75 H x 19 W x 12 12 D Weight Approx 11 65 lb 5 28 kg 186 40 oz Dimentional Figure Overall Rear View ...

Страница 8: ... case the primary power supply connected to the NETGEAR switch fails The RPS can be setup is different configurations However a typical system level setup is as shown RPS5412 Internet LAN WAN Cable Modem Router Power Generator or UPS AC Input 52VDC Output NETGEAR PoE Switch WiFi Wireless Utility Power Company Data Primary 12VDC Output ...

Страница 9: ...4 200 RPS5412 RPSC5412 GSM7248 200 RPS5412 RPSC5412 GSM7228PS RPS5412 RPSC5412 GSM7252PS RPS5412 RPSC5412 GSM7328S 200 RPS5412 RPSC5412 GSM7352S 200 RPS5412 RPSC5412 GSM7328FS RPS5412 RPSC5412 GSM7212F RPS5412 RPSC5412 GSM7212P RPS5412 RPSC5412 GSM7224P RPS5412 RPSC5412 NOTE The Model RPS5412 only provides up to 300W for POE application If POE devices connected to the switch system need more than ...

Страница 10: ... RPSC5412 AC Connection Cord see ordering chart Installation Manual Rack mount Screws Ordering Information Chart RPS Model Worldwide region RPS5412 100NAS Americas RPS5412 100EUS Europe RPS5412 100AJS Asia 15 14 1 2 7 8 9 1 15 16 8 2 3 4 5 6 7 8 14 13 12 11 10 9 RPSC5412 NETGEAR Switch Side Connector RPS5412 Side Connector ...

Страница 11: ...S Model RPS5412 has the ability to monitor output DC voltage If the front panel Green LED is ON that indicates good AC input and good DC output When the Green LED is OFF that indicates the following No AC voltage input Low DC voltage output No DC voltage output ...

Страница 12: ...that the rack is level and stable before extending a component from the rack Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent of the branch circuit rating Ensure that proper airflow is provided to components in the rack Do not step on or stand on any component when servicing other components in a rack The system chassis m...

Страница 13: ...with the holes in the rack Insert and tighten two screws appropriate for your rack through each of the oval shaped holes on the side of the RPS To Operate the RPS Power Supply after Installation Model RPS5412 may be installed in environments that meet the environmental characteristics specified in Chapter 2 It is recommended that sufficient ventilation gap be provided above or below the RPS unit f...

Страница 14: ... at the rear end of the power supply is connected to a clean and well grounded Universal AC source Once all the wires are connected properly Turn ON the rear panel switch for the RPS redundant power supply unit The Green LED should light up Indicating Power supply is ON and working properly Now the system is ready to operate to its required purpose 5 2 Maintenance Safety Instructions Please use th...

Страница 15: ...y route cables so that they cannot be stepped on or tripped over Be sure that nothing rests on any cable Do not modify power cables or plugs Install the power supply before connecting the power cable to the power supply Unplug the power cable before removing the power supply If the system has multiple sources of power disconnect power from the system by unplugging all power cables from the power s...

Страница 16: ...ith any kinds of liquids on the unit To prevent damage to LEDs and switches DO NOT place the front panel of the unit face down DO NOT press against the front and or rear panel Optimal Power Supplies LLC is not responsible for any kinds of damages direct or indirect sustained through the use of any of its products ______________________________________________________________________________ ...