Optima DM(DM) Скачать руководство пользователя страница 35

SJE Corporation Ltd. 

OPTIMA STEAMER SERIES LIMITED WARRANTY 

 

SJE Corporation Ltd. hereby warrants that new Optima Steamers purchased directly from SJE Corporation Ltd., 
headquartered in Busan, South Korea will be free from defects in material and workmanship for the period of time stated 
below, subject to certain limitations. 

 

OUR WARRANTY POLICY 

 

This warranty is not transferable and covers replacement parts only. This warranty does not cover any consequential 
damages or business loss. 

 

THE PERIOD OF WARRANTY 

 

The warranty on your Optima Steamer is twelve(12) months(6months for authorized distributors) from the date of 
purchase by the original owner against defects in material and workmanship.   

 

GENERAL EXCLUSIONS   

 

General exclusions from this warranty shall include any failures caused by: 

a. 

Installation of parts, attachments or accessories that are not original to the unit or genuine Optima Steamer parts. 

(i.e. external aftermarket attachments such as exhaust duct extension) 

b. 

Abnormal strain, neglect, or abuse. 

c. 

Lack of proper maintenance. 

d. 

Accident or collision damage. 

e. 

Changing or altering factory settings without consulting with an authorized technician. 

f. 

Damage or malfunctions resulting from natural calamity, freezing, theft, accident, vandalism, abuse due to 
misapplication and/or improper site conditions. 

g. 

Water damage 

h. 

Electrical damage from including, but not limited to improper use of extension cords, failure to meet proper 
voltage requirements, incorrect or insufficient amperage circuit. 

i. 

Insufficient unobstructed distance on exhaust 

 
Items not covered under warranty include: 

a. 

Parts replaced due to normal wear or routine maintenance including, but not limited to sensors, filters, fuses, 
valves, pipes, electrodes, cables and fittings (i.e. nipples, couplings, o-rings, etc) 

b. 

Consumable or wearing items requiring replacement as part of normal operation including, but not limited to 
steam hoses and guns. 

c. 

Any transportation or travel costs.   

d. 

Reimbursement for rental units while repairing warranty items. 

e. 

Normal maintenance items such as: draining tanks and boiler, descaling, filter and sensor changes, boiler 
cleaning, tightening and sealing bolts and fittings and others stated in the User Manual.         

f. 

Failure caused by water scale problem due to local water conditions. 

g. 

Warranty work completed after 30 days from discovery. 

h. 

Damage, problems or failure caused by factors external to the Product including, but not limited to, faulty or poor 
external electrical wiring, incorrect or faulty power supply, voltage fluctuations, over voltage transients or 
electromagnetic interference, inadequate or faulty water or fuel.   

 

CUSTOMER’S RESPONSIBILITY 

Under this warranty, the customer’s responsibility shall be to: 

a. 

Operate and maintain the machine as specified in the instructions manual. 

b. 

Give notice to authorized Optima Steamer dealer or SJE Corporation Ltd. of apparent defects within seven (7) 
days after discovery. 

c. 

Provide proof of purchase, purchase date, and serial number of the warranty item(s). 

d. 

Make the unit available for inspection and repairs at dealer's place or service center. If shipped, transit costs 
should be prepaid. 

 

For warranty service request, please e-mail [email protected] or call +82 51 521 3200. 
SJE Corporation Ltd. recommends that you read the Operating Instructions, and in particular the troubleshooting 
guide on USER'S MANUAL before you make a Warranty service call

Содержание DM(DM)

Страница 1: ......

Страница 2: ...Manufactured by SJE Corporation Ltd User s Manual Including Operating and Maintenance Instructions Model OPTIMA DM Series For DM DM DM DMF DM DS Ver 4 7 1 Distributor s Contact Information...

Страница 3: ...ax 82 51 521 3305 Website http www sjecorp com E mail info sjecorp com All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by a...

Страница 4: ...3 Product Specifications 4 Exterior Descriptions 5 Pre start Procedures 7 Initial Operation 9 Standard Operating Procedures 10 Moisture Control 11 Pause Operations 12 Shutdown Procedures 12 Freeze Pr...

Страница 5: ...or filtered water under 15 ppm Soft water is recommended Otherwise use only clean tap water with anti scaling solution Use only clean diesel Provide adequate electrical power requirements accordingly...

Страница 6: ...or lack of experience and knowledge unless they have been given supervision or instruction Keep the Optima away from children and animals at all times Children should be supervised to ensure that the...

Страница 7: ...l detection error on Water tank level low flashing Alarm beeps once Alarm beeps continuously Do not direct the steam jet at people live electricity animals etc Read the manual Warning risk of burns Wa...

Страница 8: ...A Water Consumption Rate Max 300 1200cc min 0 08 0 32gpm Fuel Tank Capacity 20 5 3 gals 17 4 5 gals Fuel Nozzle 1 10 gallon hour 10 0 bar Net Weight kgs lbs 85 kgs 187 lbs 87 kgs 192 lbs 93 kgs 205 lb...

Страница 9: ...k 6 Throttle door 7 Front wheel 8 Y strainer 9 Non return valve 10 Quick Plug for feed water DMF only 11 Drain valve 12 Moisture control valve 13 Turning wheel with brake 14 Steam outlet 15 Warning st...

Страница 10: ...ith brake 9 Chassis 10 Door lock knob 11 Stationary wheel 12 Hose fitting for feed water 13 Steam outlet 14 Warning sticker 15 Front cover 16 Sticker of Certification 17 Operating switches 18 Pressure...

Страница 11: ...use tools 2 Fill the water tank with soft water When tap water is used add anti scaling solution to the water tank as instructed by the supplier Do not use distilled water Automatic Water filling Syst...

Страница 12: ...sel 4 Plug the machine into an electrical outlet with all the switches on the machine off If an extension cord is used the plug and the socket must be of watertight construction Inadequate extension c...

Страница 13: ...WER light on and WATER TANK light is flashing and the alarm is going off This means the float switch in the water tank does not detect water Add water to the water tank C The POWER light on and FUEL T...

Страница 14: ...3 minutes 3 After the steam pressure reaches 8 5 bar 123 2 psi open the steam outlet valve s and begin to operate Review all safety precautions on page 1 2 Never leave the machine unattended The exha...

Страница 15: ...valve accordingly When cleaning and or sterilizing interior surfaces ensure that the moisture control valve is closed to minimize surface moisture Wet steam may persist in extremely humid or cold weat...

Страница 16: ...til the pressure drops to 1 2 bar 15 29 psi Then drain out all water from steam vessel by opening the drain valve If the water from the steam vessel is milky open the Y strainer drain valve cap and cl...

Страница 17: ...ne from electrical source and follow steps below to protect the Optima against ruptured lines and damage caused during cold climates Steps 1 Empty the steam vessel Slowly open the drain valve cap once...

Страница 18: ...e the machine at room temperature Note Doing freeze prevention maintenance can prevent costly repairs Frozen water can rupture lines cause malfunctions and destroy parts Never operate the machine if a...

Страница 19: ...vary based on the hardness of water in your area A Add anti scaling water treatment Add the recommended dosage of anti scaling water treatment into the water tank Use a TDS meter to determine the hard...

Страница 20: ...ining water from the steam vessel by opening the Y strainer drain valve or cap C Drain the water fuel tank Drain water and fuel tanks by removing the drain caps from both tanks This will flush out sed...

Страница 21: ...UED WRENCH sandpaper and Teflon tape Steps 1 Unplug the electric cord and let the steam pressure drop to 0 2 Cool down and drain the steam vessel by opening the drain valve 3 Remove the top cover or o...

Страница 22: ...scaling liquid and 2 liters 0 5 gal of clean tap water Steps 1 Remove the top and lateral covers 2 Open the drain valve and release all water from the vessel Close the drain valve afterwards 3 Disconn...

Страница 23: ...e de scaling liquid label Do not exceed the recommended time to avoid steam vessel damage 11 Drain the steam vessel by opening the Y strainer drain cap and temporarily remove the strainer to prevent s...

Страница 24: ...H Remove soot in combustion chamber What you will need screw driver 10mm wrench vacuum cleaner towel and brush Steps 1 Remove all covers and disconnect the H V cables and fuel pipe from top of the cyl...

Страница 25: ...bolts and detach all of support brackets from control box d Detach a flexible intake hose from the cylinder e Loosen the band located at the bottom of the cylinders Lift up to remove inner and outer...

Страница 26: ...e for air purge If the Thermistor reading is below the preset range the machine will release air from inside the steam vessel at initial pressurizing stage This will prevent any machine operation inte...

Страница 27: ...0 seconds at initial operation Warning When steam pressure arise above 8 5 bar 123 2 psi When steam pressure gauge indicates above 8 5 bar 123 2 psi you must turn off both STEAM and POWER EMERGENCY ST...

Страница 28: ...run on Water tank level low flashing Low water level detection error on Fuel tank level low flashing Flame error on Alarm beeps continuously Alarm beeps once Continuous pressure decrease Continuous p...

Страница 29: ...onnect the wire from the float switch If the signal clears replace the float switch 5 Float switch in the fuel tank is not detecting diesel fuel due to 1 Fuel shortage AND OR 2 Malfunction with the fl...

Страница 30: ...to 1 Fuel filter Fuel pump performance degradation Line is clogged 2 Malfunction of the Electrodes Ignitor or Blower Fan 3 Interference of light to the sensor day light any light 4 Malfunction of the...

Страница 31: ...Y strainer has cracked due to freezing weather condition 2 Safety valve bursts open due to overpressure in the vessel 1 Thaw the machine at room temperature Inspect it for additional damages Replace...

Страница 32: ...air due to 1 Closed blower fan damper OR 2 The combustion chamber has built up too much soot 1 Increase the air intake on the blower fan by opening the damper Loosen tightening screw and use adjusting...

Страница 33: ...OPTIMA DM DMF is designed to use with various useful optional items as below 1 Various accessories 2 Omega Softener Caution Please refer to the instruction of each item before using optional items wi...

Страница 34: ...continuously after STEAM switch is on 5 Please check 4 LED lights on the control panel box and let us know indication of them as light on LO light flashing BK or off OFF in each blank below POWER Ligh...

Страница 35: ...rts replaced due to normal wear or routine maintenance including but not limited to sensors filters fuses valves pipes electrodes cables and fittings i e nipples couplings o rings etc b Consumable or...

Страница 36: ......

Отзывы: