- When
Iris
mode is deactivated, camera goes to
Brightness
mode.
Exp ... :
Exposure mode
is activated if
Iris mode
button is held pressed for minimum two
seconds. Indication LED starts flashing slowly when camera is on
Exposure mode
.
- When
Exp
is activated, exposure time of the image sensor is controlled manually by
Joystick up/down. Gain will be fixed to a low value and Iris will remain unchanged when
Exposure
mode is activated.
Note:
Exposure control is useful for producing good pictures at Iris mode when illumination
level is too high or too low.
Note:
Long Exposure time (Joystick up) affects frame rate of the camera negatively.
Note
: Selecting
Auto B
button resets Iris size and Exposure time to factory default values.
Colour:
Sets white balance of the camera to 3 different colour temperatures. Press
Colour
button to toggle between Automatic, Cold and Warm colours.
Freeze:
Freezes the live video. Indication LED lights when image is freeze. Pressing any
button or moving joystick will reset the image to live.
R (…s):
Saves and Recalls camera adjustments.
- Press and hold the
R
button for 5 seconds until green (control) LED starts to flash.
Current adjustments, like zoom position, brightness, iris size, exposure time and colour
are recorded in camera.
- Press
R
shortly to recall recorded adjustments any time.
All rights reserved. The information contained herein is designed only for use with Optilia Instruments AB HD
Inspection Cameras. Optilia Instruments AB is not responsible for any use of this information for other purposes.
Optilia Instruments AB shall not be liable to the purchaser of this product or third parties for damages, losses,
costs or expenses incurred by the purchaser or third parties as result of: accident, misuses, or abuse of this
product or unauthorized modifications, repairs or alternations to this product, or failure to strictly comply with
Optilia Instruments AB´s operating and maintenance instructions
Optilia Instruments AB shall not be liable for any damages or problems arising from the use of any options or
any consumable products other than those designated as original Optilia products or Optilia approved products
by Optilia Instruments AB.
Optilia Instruments AB shall not be held liable for any damages resulting from electromagnetic interference that
occurs from the use of any interface cables or devices other than those provided by or designated as Optilia-
approved Products by Optilia Instruments AB.