EDFA-MP-MSA
User’s Manual
Page 4 of 9
Optilab, LLC
600 E. Camelback Road, Phoenix, AZ 85012
Phone: (602) 343-1496, Fax: (602) 343-1489, Email: [email protected]
2.4 30 Pin-Out Diagram
Listed below is the pin-out diagram for the 30 pin port on the external of the
EDFA-MP-MSA module:
2.5 Operation Instructions
Start-up Procedure
1. Ensure that the proper cable connections are made, which includes the
cable assembly interconnects (as shown on page 4) and the 30 pin
connection between the module and power supply.
2. Plug in the After plugging in the AC/DC Power Adaptor into the appropriate
socket, the 5V VDC supply will automatically be enabled to the EDFA.
3. Ensuring the optical input signal is turned off, connect the optical signal for
amplification via the optical input port using the indicated connector
patchcords.
4. Connect the optical output port using the indicated connector patchcords to
the appropriate signal destination to utilize the amplified optical output signal.
5. After checking all physical patchcord connections, turn the input signal laser
source on.
6. The EDFA-MP-MSA is now enabled, with the gain current set to maximum
amplification for the current input signal level.