Optilab EDFA-MP-MSA 

User’s Manual

 

Erbium Doped Fiber Amplifier 

 High Power MSA Complaint Module 

 
 

 

 

 

 

 

Caution

The  user  must  read  this  manual  before  operating  the  EDFA-MP-MSA  unit.  

Operations  other  than  those  described  in  this  manual may result  in personal 
injury and damage to the unit.

 

 
 

Note  that  any  attempt  to  open  or  fix  the  equipment  without  prior  approval  by 
Optilab, LLC. voids the warranty. 

 
 
 

Ver. 1.6 

January 5

th

, 2022 

Содержание EDFA-MP-MSA

Страница 1: ...e user must read this manual before operating the EDFA MP MSA unit Operations other than those described in this manual may result in personal injury and damage to the unit Note that any attempt to op...

Страница 2: ...ical pin definitions 1 3 03 27 19 Logo and format update 1 4 03 29 19 Command set updated 1 5 05 01 19 Housing mod PN change base specs did not change 1 6 01 05 22 Power supply update Copyright 2022 b...

Страница 3: ...MATION 1 1 1 INTRODUCTION 1 1 2 PRODUCT OVERVIEW 1 1 3 FEATURES 1 1 4 USER SAFETY 1 2 OPERATION 2 2 1 INTRODUCTION 2 2 2 INITIAL INSPECTION 2 2 3 CONTROLS 2 2 4 30 PIN OUT DIAGRAM 4 2 5 OPERATION INST...

Страница 4: ...are equipped to ensure the reliability and safety of the device The module requires only a single 5VDC power supply for operation with total current draws as low as 260mA in saturation output mode 1 3...

Страница 5: ...until the contents of the shipment have been checked to be free of mechanical and electrical damages Notify Optilab LLC promptly if any notable damage is found 2 3 Controls FEATURE FUNCTION ELECTRICA...

Страница 6: ...FA module for operation It is a 30 pin connector DC POWER SOCKET The DC power socket is connected to a DC power source The standard DC power source is the AC DC power adapter RS232 PORT Using a RS232...

Страница 7: ...er supply 2 Plug in the After plugging in the AC DC Power Adaptor into the appropriate socket the 5V VDC supply will automatically be enabled to the EDFA 3 Ensuring the optical input signal is turned...

Страница 8: ...able the optical output of the EDFA module 2 Swap patchcords as desired Only connect the indicated connector patchcords to the optical input output receptacles cleaning them as necessary 3 Re enable t...

Страница 9: ...module to a PC using the following connection diagram and serial port settings 2 7 RS232 Command Set When the electrical connections have been made and the software settings for serial port transmissi...

Страница 10: ...he optical connectors Always apply dust cover plugs to unused optical ports to prevent the damage of optical connectors C Improper pin connections S If directly connecting the voltage to the 30 pin co...

Страница 11: ...Optilab LLC 4 2 Service and Calibration Your EDFA MP MSA unit has been designed to provide years of trouble free operation No internal maintenance is required provided that the equipment is properly h...

Страница 12: ...optical connector with an optical microscope to verify cleanliness Repeat steps 2 to 5 as needed Cleaning Optical Connector Sides Receptacles Adaptors with Swab and Alcohol Dust or particles can adher...