background image

Opticon 

OPR 3001 

Specifications Manual 

 
 
 

 

27 

9.2.  Scanner Connector Specification 

CN801 (13-pin) 

Signal Name 

 

Pin Number 

RS-232C USB  Wedge 

1 NC VCC 

VCC 

2 R×D NC  NC 

3 T×D NC  NC 

4 NC NC 

CPU_CLK 

5 NC NC 

CPU_DATA 

6 GND GND GND 

7 NC USB+ NC 

8 NC USB- NC 

9 NC NC 

KB_DATA 

10 NC  NC 

KB_CLK 

11 CTS  NC  NC 

12 RTS  NC  NC 

13 VCC  NC  NC 

10. Readable Barcodes 

10.1. Menu Barcodes: Default Settings 

Default menu barcodes set the scanner to factory defaults. 

RS-232C Default 

Functions 

Menu labels 

Menu codes 

SET 

_ZZ_ 

ZZ 

RS-232C 

_U2_ 

U2 

Single tone 

buzzer: 3 kHz* 

_W1_ 

W1 

Buzzer duration: 

50 ms* 

_W7_ 

W7 

Read mode 

options: Single 

read* 

_S0_ 

S0 

END 

_ZZ_ 

ZZ 

Содержание OPR 3001

Страница 1: ...OPR 3001 Rugged Handheld Laser Scanner Specifications Manual ...

Страница 2: ... that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon Inc assumes no liability for any direct indirect consequential or incidental ...

Страница 3: ...Specification 9 6 2 Laser Scanning Standard 9 6 2 1 Laser Scanning Tilt 9 6 2 2 Scanning Curvature 9 7 Technical Specifications 10 7 1 Print Contrast Signal PCS 10 7 2 Scan Area and Resolution 11 7 3 Pitch Skew and Tilt 12 7 3 1 Pitch Angle 12 7 3 2 Skew Angle and Dead Zone 13 7 3 3 Tilt Angle 14 7 4 Curvature 15 8 Interface Specifications 16 8 1 RS 232C Interface Specification 16 8 1 1 Settings a...

Страница 4: ...ttings 2 Read Options Trigger Buzzer 30 11 Serial Number 31 12 Packaging Specifications 32 12 1 Individual Packaging Specification 32 12 2 Collective Packaging Specification 33 13 Durability 34 13 1 Electrical Noise 34 13 2 Static Electricity 34 13 3 Shock 35 13 3 1 Product Drop Test 35 13 3 2 Shock Individual Package Drop Test 35 13 4 Vibration Strength 35 13 4 1 Vibration without packaging 35 13...

Страница 5: ...gure 8 Interface circuit 17 Figure 9 Character format same for both sending and receiving 17 Figure 10 Communication format 18 Figure 11 No handshaking 18 Figure 12 Busy Ready communication 18 Figure 13 Cannot receive command 19 Figure 14 Signal timing 19 Figure 15 Modem transmit data 20 Figure 16 ACK NAK 21 Figure 17 ACK NAK No response 22 Figure 18 USB interface circuit 23 Figure 19 RS 232C cabl...

Страница 6: ...gth red laser beams enhance the visibility of scanning lines for easier aiming under adverse lighting conditions The OPR 3001 is available in USB RS 232C and Wedge interfaces Supported symbologies JAN UPC EAN all add on Codabar NW 7 including ABC and CX Chinese Post Matrix 2 of 5 Code 39 Normal Code 39 Full ASCII Code 39 Italian Pharmaceutical Code 11 Code 93 Code 128 EAN 128 IATA Industrial 2of5 ...

Страница 7: ...erature and Humidity Temperature 10 to 60 C Humidity 5 to 90 RH 4 2 Storage Temperature and Humidity Temperature 30 to 70 C Humidity 5 to 90 RH 4 3 Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values Incandescent light to 4 000 lx Fluorescent light to 4 000 lx Sunlight to 80 000 lx Figure 1 Ambient l...

Страница 8: ...l Characteristics Parameter Symbol Min Typ Max Unit Remarks 5 4 6 0 6 6 V RS 232C Power supply voltage 4 5 5 0 5 5 V USB and Wedge 96 130 mA RS 232C when emitting Operating current IOP 90 125 mA USB and Wedge when emitting laser 400 600 mA RS 232C Rush current IPEEK 300 500 mA USB and Wedge 35 60 mA RS 232C Stand by current IPRE 30 55 mA USB and Wedge Conditions Connect 1Ω resistance to a power su...

Страница 9: ...ilt Laser scanning tilt is the vertical difference between both ends of a laser scan line Measure it in the middle of the laser scan line Up to 1 2 degrees angle in vertical direction from the scan origin mirror motor Up to 3 1 mm at 150 mm from the scan origin 6 2 2 Scanning Curvature The maximum difference between the laser scan line and the line between both ends of the laser scan line Measure ...

Страница 10: ...1º C 70º F 60 RH Ambient Light 500 to 900 lx Background Barcode black Space white Margin white Background of label black Power Supply Voltage 6 0 V RS 232C 5 0 V USB and Wedge Decoding Test Approve the performance when decoding is successful in all ten tests Decoding is deemed successful when completed in 0 5 second or less 7 1 Print Contrast Signal PCS 0 45 or higher over 70 of reflectivity of sp...

Страница 11: ...on the scan origin Figure 3 Scan area and resolution in mm Resolution Symbology PCS Quiet Zone Digit Decode depth mm 1 0 mm CODE 39 0 9 25 mm 1 30 590 0 5 mm CODE 39 0 9 18 mm 3 10 360 0 25 mm CODE 39 0 9 10 mm 8 10 200 0 15 mm CODE 39 0 9 7 mm 10 10 90 0 127 mm CODE 39 0 9 5 mm 4 20 60 Conditions Barcode Sample OPTOELECTRONICS Test Sample N W Ratio 1 2 5 Angle α 0 β 15 γ 0 Curvature R ...

Страница 12: ...Opticon OPR 3001 Specifications Manual 12 7 3 Pitch Skew and Tilt 7 3 1 Pitch Angle α 35 α 3 5 α 3 5 Figure 4 Pitch ...

Страница 13: ...001 Specifications Manual 13 7 3 2 Skew Angle and Dead Zone Skew angle β 50 Excluding dead zone Dead zone β 8 There are some areas in which decoding fails due to specular reflection Figure 5 Skew angle and dead zone ...

Страница 14: ...dge of the scanner Label Pitch Angle Skew Angle Dead Zone PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Angle Pitch Angle Skew Angle β 15 Tilt Angle γ 0 Tilt Angle Pitch Angle α 0 Skew Angle β 15 Skew Angle Dead Zone Pitch Angle α 0 Tilt Angle γ 0 Curvature R ...

Страница 15: ...rformance is guaranteed when R 15 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm Figure 7 Curvature Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 26 mm Quiet Zone 10 mm Distance 60 mm from the edge of the scanner Angle Skew Angle β 15 ...

Страница 16: ...ace default Item U2 setting Baud rate 9600 BPS Start stop bits 1 bit Data bits 8 bits Parity bits No parity Handshaking No handshake Flow Control Time Out Indefinitely You can change the communication condition using the menu barcode 8 1 2 Signal Level Signal Name I O RS 232C Level V Mark OFF Space ON TxD OUT 5 to 15 5 to 15 RxD IN 3 to 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 ...

Страница 17: ...Opticon OPR 3001 Specifications Manual 17 8 1 3 Interface Circuit Figure 8 Interface circuit 8 1 4 Character Format Figure 9 Character format same for both sending and receiving ...

Страница 18: ...2 ACK NAK P3 ACK NAK NO RESPONSE P4 a No Handshaking The scanner attempts the communication regardless of the state of the host computer Figure 11 No handshaking b BUSY READY The scanner and the host computer notify each other of their state and whether they can receive data with BUSY READY through an RTS line They can communicate state to each other through a CTS line when connected as in the fol...

Страница 19: ...ndication buzzer when the CTS line is not ON within a specified period The Flow Control time outs are as follows and the default setting is indefinitely I0 Flow Control Time Out Menu Command Indefinitely I0 100 ms I1 200 ms I2 400 ms I3 CTS TxD signal timing When the CTS line is turned OFF while sending a TxD signal the scanner transmits one character and waits When the RTS signal is turned ON whi...

Страница 20: ...Opticon OPR 3001 Specifications Manual 20 c MODEM The scanner turns CS line ON before transmitting data Other processes are the same as BUSY READY Figure 15 Modem transmit data ...

Страница 21: ...l state NAC response Action The scanner sends the data again and waits for the response from the host DC1 response Action The scanner returns to waiting for the trigger if it has a trigger the initial state None response Action The scanner sounds the error buzzer and returns to the initial state ACK NAK timeout can be set as follows using the menu or commands ACK NAK timeout Menu Command Indefinit...

Страница 22: ... NAK NO RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the same as ACK NAK Figure 17 ACK NAK No response ...

Страница 23: ... the scanner is transmitting the data to the host it may cause data transactions to fail 8 3 Wedge Interface Specification 8 3 1 Settings and Communication a With desktop PC using external keyboard Reading menu barcodes ZZ UB KM ZZ can set the DOS V Wedge interface default b With notebook PC not using external keyboard Reading menu barcodes ZZ UB KL ZZ can set the DOS V Wedge interface default Do ...

Страница 24: ... 1 conductive wire Weight Approximately 80 g Figure 19 RS 232C cable a Pin Assignment Pin No Signal Name Notes 1 NC Open not assigned 2 TXD 3 RXD 4 Pin no 6 and jumper 5 GND 6 Pin no 4 and jumper 7 CTS 8 RTS 9 NC Open not assigned Connector A connector with a plug for external power supply D sub 9 pin female Power Supply φ4 0 inside diameter φ1 7 Exterior electrode of the plug is GND and interior ...

Страница 25: ...9 1 2 USB Cable Standard specification Type Straight Diameter Φ4 8 0 5 mm Length 1500 50 0 mm Cores 4 insulated wires 1 conductive wire Weight Approximately 60 g Figure 20 USB cable a Pin Assignment Pin No Signal Name 1 VCC 2 DATA 3 DATA 4 GND ...

Страница 26: ... Diameter Φ4 8 0 5 mm Length 1500 50 0 mm Cores 8 insulated wires 1 conductive wire Weight Approximately 80 g Figure 21 Wedge cable a Pin Assignment DOS V Host Side DOS V Keyboard Side Pin No Signal Name Pin No Signal Name 1 CPU_DATA 1 KEY_DATA 2 2 3 GND 3 GND 4 VCC 4 VCC 5 CPU_CLK 5 KEY_CLK 6 6 ...

Страница 27: ... GND GND 7 NC USB NC 8 NC USB NC 9 NC NC KB_DATA 10 NC NC KB_CLK 11 CTS NC NC 12 RTS NC NC 13 VCC NC NC 10 Readable Barcodes 10 1 Menu Barcodes Default Settings Default menu barcodes set the scanner to factory defaults RS 232C Default Functions Menu labels Menu codes SET _ZZ_ ZZ RS 232C _U2_ U2 Single tone buzzer 3 kHz _W1_ W1 Buzzer duration 50 ms _W7_ W7 Read mode options Single read _S0_ S0 END...

Страница 28: ...labels Menu codes SET _ZZ_ ZZ USB default _SU_ SU END _ZZ_ ZZ Wedge Default with external keyboard Functions Menu labels Menu codes SET _ZZ_ ZZ AT Wedge default _UB_ UB Keyboard layout with keyboard _KM_ KM END _ZZ_ ZZ Wedge Default without external keyboard Functions Menu labels Menu codes SET _ZZ_ ZZ AT Wedge default _UB_ UB Keyboard layout without keyboard _KL_ KL END _ZZ_ ZZ ...

Страница 29: ...AN 8 X CR EAN 8 Add on X X CR Code 39 X X CR Not transmit ST SP Code 39 Trioptic X X CR Not transmit ST SP NW 7 CODABAR X X CR Not transmit ST SP Industrial2of5 X X CR Interleaved2of5 X X CR Code 93 X CR Code 128 X CR EAN 128 X X CR S Code X X CR MSI Plessey X CD1 CD1 CR UK Plessey X CR Telepen X X CR Matrix2of5 X X X CR Chinese Post Matrix 2of5 X X X CR IATA X X CR RSS 14 X X CR RSS limited X X C...

Страница 30: ...ptions Trigger Buzzer Item Default Setting Setting the number of characters Fixed length OFF all codes Read mode Multiple read Multiple read reset time 500 ms Add on wait mode 500 ms Multiple read Disable multiple read Multiple columns read Disable multiple columns read Redundancy Read 1 times redundancy 0 Trigger switch Enable trigger Trigger repeat Disable trigger repeat Auto trigger Disable aut...

Страница 31: ...Opticon OPR 3001 Specifications Manual 31 11 Serial Number The serial number as shown below is affixed to the scanner Figure 22 Serial number diagram ...

Страница 32: ...the scanner in a protective foam bag and place it in a single packing box The scanner shown is an RS 232C unit Descriptions on an individual packaging box label differ depending on the interface type The RO mark may be indicated on the upper side of the individual packaging box label Figure 23 Individual packaging ...

Страница 33: ...ndicated on the upper side of the individual packaging box label Figure 24 Collective packing Note The RO mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC However this document does not have any legal ...

Страница 34: ...bology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 100 mm from the edge of scanner Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 6 0 V RS 232C 5 0 V USB and Wedge 13 2 Static Electricity Air discharge 8 kV max No malfunction 15 kV max No destruction Contact discharge 6 kV Contact discharge at the hook and the screw Measurement environment Use electrostatic testing device compli...

Страница 35: ...om angles on its top bottom front back left right top left top right bottom left bottom right 13 4 Vibration Strength 13 4 1 Vibration without packaging Swept with 10 Hz to 100 Hz acceleration 19 6 m s2 2 0G Added a vibration to each X Y and X direction for 30 minutes 1 cycle 60 minutes under non operational conditions Observed no abnormality in either appearance or performance 13 4 2 Vibration in...

Страница 36: ...million times on RS 232C and Wedge cables and repeated 1 million times on USB cable Observed no abnormality in either structure or performance Note Cable bending resistance is not warrantable Figure 26 Cable bend strength 14 Reliability MTBF mean time between failures of this product except for the laser diode and the mirror motor scan unit is 30 000 hours Life cycle of the laser diode is 10 000 h...

Страница 37: ...om the surface when the auto trigger is used Auto trigger distance 40 mm from the edge of the scanner Conditions Moving Speed 100 10 mm s Angle Skew angle excluding pitch angle and dead zone Environmental Temperature and Humidity Room temperature and humidity Environmental luminance 500 to 900 lx Conditions for the auto trigger 1 Barcode sheet OPTOELECTRONICS Test Sheet white Background OPTOELECTR...

Страница 38: ...oduct Safety EN60950 1 2001 IEC60950 1 2001 16 3 EMC EN55022 EN55024 FCC Part15 Subpart B Class B This device complies with part 15 of FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation VCCI Class B This is a Class B product ...

Страница 39: ...not forcibly bend the cables at low temperatures 17 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 17 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not use the scanner near a radio or a TV receiver It may cause reception problems The scanner may be damaged by voltage drops The scanner m...

Страница 40: ...Opticon OPR 3001 Specifications Manual 40 18 Mechanical Drawing Dimensions 3 W 68 X D 150 X H 155 mm except protruding portion Figure 28 Mechanical drawing ...

Отзывы: