NLV
-
3101
-
HD
Specifications Manua
l
28
9.9.
Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test:
Drop the scanner three times (15 times in total), at each 5 face, from a height of 75 cm
onto a concrete floor as shown below.
Figure 22: Drop Test
9.10.
Drop Impact Strength (in individual packaging)
There shall be no sign of malfunction after the following drop test.
Drop test:
Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges, and
6 faces, from a height of 100 cm onto a concrete floor.
9.11.
Electrical Specifications
Withstand Voltage
: AC 1500 V / 60 seconds, 10 mA or less
Insulation Resistance
: DC 500 V, 2 M
Ω
or higher
Current Leakage
: 250
μ
A or less / AC 250 V 60 Hz
Power Line Noise Immunity
: ±1 kV or lower
Electrostatic Discharge Immunity
: No destruction found (±15 kV, air or direct discharge)
: No malfunction found (±10 kV, air or direct discharge)
: ±6 kV (contact, direct or indirect discharge)
*Testing method is compliant with IEC-61000-4-2. (150 pF, 330
Ω
)
Содержание NLV-3101-HD
Страница 10: ...NLV 3101 HD Specifications Manual 5 ...
Страница 29: ...NLV 3101 HD Specifications Manual 24 ...