Chapter 1
•
Configuring MGW x100
Configuring MGW x100 45
To set a default gateway:
y
In the command line, type
defaultGateway <default gateway IP
> and press
ENTER
;
the default gateway is set.
Note
The default gateway applies only to the management network.
For example:
defaultGateway 172.16.195.256
To set the time and date:
y
In the command line, type
setTime <hour> <minute> <day> <month> <year
> and press
ENTER
;
the new date and time are set.
To set MGW x100 to 15.20h on April 3, 2009:
setTime 15 20 03 04 2004
To view the time and date:
y
In the command line, type
showTime
and press
ENTER
; the time and
date are displayed
.
Note
Viewing the time and date can be also performed using the MGW EMS application.
To view and issue additional commands:
1.
To enter the menu, type
help
; the menu appears.
2.
To view available commands for your selection, type
help <your
selection
>, for example
help TCP/IP
; the relevant commands appear
with a short explanation.
3.
To view the required syntax for the desired command, type
help <the
desired command
>, for example
help ipConfig
; the required syntax
appears with an example.
4.
To issue the desired command, type the command with the required
syntax and press
ENTER
; the command is executed.
Note
y
We recommend configuring Controller B's interfaces using MGW EMS, although you
may use HyperTerminal after connecting the Configuration PC to Controller B's serial
port (COM1).
y
If you have Controller B and Switch B installed as a backup (hot standby), make sure to
StockCheck.com