Chapter 4
•
Replacing Hardware Components
186 Replacing Hardware Components
Replacing Fuses
Fuses are located at the rear next to the power switch. If necessary, purchase
the following fuses from Littlefuse:
y
For AC powered platforms:
2
׳
Littlefuse, catalog number 218010
(10A 250V)
y
For DC powered platforms:
2
׳
Littlefuse, catalog number 314020
(20A 250V)
y
For further information, refer to
http://www.Littlefuse.com
.
AC powered Platforms
Figure 60
:
The Fuse Chamber and the Power Inlet on AC powered Platforms
1.
Make sure that MGW x100's power switch is in
Off (0)
position, unplug
MGW x100 from the power outlet and then disconnect the power cord.
2.
To open the fuse chamber, insert a thin screwdriver into the slit and
gently pull the fuse tray outwards. You cannot remove the fuse tray.
3.
Replace the two fuses and gently close the cover. The fuse chamber is
closed when you hear a click.
DC powered Platforms
1.
Make sure that MGW x100's Power switch is in
Off (0)
position,
disconnect MGW x100 from the DC power outlet and then disconnect the
12AWG copper conductors.
2.
Open the fuse chamber by unscrewing the cover. The fuse chamber is
located on the rear above the connectors and below the power switch.
3.
Replace the fuse and close the fuse chamber.
To replace flash disks and fuses, use only spare parts supplied or approved by Optibase.
Other spare parts may damage MGW x100 and void the warranty.