Warning
• Do not mix batteries that have different levels of
power remaining (i.e., new and used batteries or
batteries of different manufacturers).
Not observing the above may result in an explosion,
leakage of electrolyte, emission of toxic gases or
other outcomes that may be harmful to people and
property.
• Remove
all
batteries prior to replacing with new
ones. If this is not followed, the low battery indicator
LED will not reset and continue to blink.
INSTALLATION
3
Caution
3
4
Cut the supplied Velcro tape to
an appropriate length and apply.
Insert two or four batteries into the back box.
Recommended batteries
SAFT LSH20
3.6 V 13 Ah
Velcro tape
Caution
Note>>
3-2 WALL MOUNTING
3-1 SEPARATING
1
Using a screwdriver or similar tool, break the
knockout position (x6) in the back box as shown.
1
Remove the cover.
3
Using Velcro tape, fix the wireless transmitters in the back
box.
Note>>
Pull
3
Loosen the
cover lock
screw.
2 Twist it
lightly.
1
• Do not place the main unit where it is exposed to direct
sunlight. Doing so may cause damage to the product.
Note>>
Knockout position
• The knockout positions are
marked "WALL" as shown.
• For more information on wiring, see 3-4
"WIRING" on page 7.
• When using battery common use unit BCU-4
(option), refer to the corresponding manual.
• Use of batteries other than recommended may shorten
the battery life. In that case, use four batteries.
Remove the chassis from the back box.
2
Mount the back box to the wall.
Note>>
2
Remove the main unit from the chassis.
Pull the upper part of main
unit, and raise it to remove.
2
Turn the
optical unit 90 degrees
and loosen the screws (both sides).
1
Note>>
Battery life: Transmitter 4 years (2 in the transmitter)
Receiver 5 yeras (2 in the receiver)
when using LSH20 (3.6V, 13Ah)
batteries manufactures by SAFT
Up to 8 batteries (4 in the transmitter, 4 in the receiver)
(
(
1.
2.
3.
4.
loosen
loosen
loosen
The screws to secure the
back box cannot be
removed from the chassis.
A coin
(Not included)
4×20 self tapping
(with rubber washer)
Side wall
Distance from the side wall:
at least 1m
If two detectors are
installed, the distance
between the upper and
lower detector should
be at least 20mm.
Caution
• When the waterproof packing is detached, be sure to
attach it on the back of the chassis before mounting.
Not doing so may compromise IP rate of this
product.
Force into
a groove
Pitch: 83.5 mm
For connection
to gang electric
box
ENGLISH
FRANÇAIS
DEUTSCH
IT
ALIANO
ESP
AÑOL
PORTUGUÊS
EN-3