background image

Unit: inches (mm)

1. The system is not operating

Check the transmitter.

Does the status indicator light up when 

you trigger the transmitter?

Check to see whether the battery is inserted correctly.

 

If the battery is old, replace it with a new one.

Is the status indicator

of the transmitter flashing?

The battery is old. Replace the battery.

Check the receiver.

Is the power indicator of the RC-20U lit? 

Is the receiver on? Check the wiring and connection.

Have all the transmitter codes have been 

taught correctly? 

Teach the transmitter codes correctly. The system will 

not operate without this process. 

 

Is the volume setting correct? 

Is the volume set to “0”? If so, readjust the volume.

Are there other high power appliances using the

same electrical power outlet? 

Please connect the RC-20U to a different electrical 

outlet.

The zone indicator of the RC-20U is on, but 

nothing happens.

Check to see whether the terminal is properly 

connected to other devices. 

Are the zone indicators flashing slowly? 

Follow directions in 10 LOW BATTERY INDICATION.

Is there anything blocking the transmission? 

Relocate the receiver and/or the RC-20U. Metal 

objects can shorten the effective transmission range.

2. The system is not operating correctly.

The RC-20U does not learn the transmitter 

codes. 

The RC-20U gets reception in the wrong zone. 

 

Check whether the transmitter codes have already 

been learned in a different zone. If so, erase the 

memory and teach again.

Erase memory in the zone in which the RC-20U responds 

and teach using the correct zone. 

The RC-20U does not respond to some of 

the transmitters.

You may have taught multiple transmitter codes in 

the same zone. Teach the transmitter codes for which 

no response is received using an empty zone.

A certain zone seem to malfunction.

This is probably the transmitter’s problem. Check the transmitter 

that corresponds to that zone.

Before contacting the supplier! 

Go through the setups again after turning on the 

power while holding down switch 1.

 

If the above solutions do not work, please contact your supplier for services.

Model 

Description

Power Source 

Chime Tone
Volume

Relay output

Output Timer

Frequency 

Operating 

Temperature

Installation Location

RC-20U

Chime Box w/Relay Receiver

3 Tone & Continue Zone (Selectable)

9VDC (Exclusive AC Adaptor)

Power Consumption 8W Max. (Including AC Adaptor 120V, 

60Hz)

Adjustable: 0~80dB/ 5 levels

Selectable: Off/1/5/30/60sec/ Utility output mode

Status Indicator

Power Indicator: Green

Zone Indicator: Red x 3

Form “C” MAX 1A/50VAC 24VDC

418MHz

15° F ~ 105° F (-10°C ~ +40°C)

 

Indoor

Accessories

Mounting Screw × 1. AC Adaptor

Weight

6.0 oz (170g)

Specifications may change without notice

7   VOLUME ADJUSTMENT

8   TERMINAL OUTPUT DURATION ADJUSTMENT

9

  TROUBLESHOOTING

10

  LOW BATTERY INDICATION

11

  SPECIFICATION

12

  DIMENSIONS

14

  WARRANTY

13

  COMPLIANCE

1. This product is warranted under normal use for 2 years from the date of purchase. If the

    product proves to be defective, return it with a copy of your dated sales receipt for repairs or

    replacement without charge.

2. The warranty is not applicable when below circumstances will be found:

 • Mechanical or electrical modification(s) are made to the product or it is otherwise altered

   manually.

 • The product is already been serviced at place(s) other than the manufacturer.

 • It is determined that the product malfunction has resulted from improper use or from an

   accident.

 • No copy of the dated sales receipt has been submitted together with the product to be

   serviced.

FCC ID : DC9RC-20U

The changes or modifications not expressly approved by the OPTEX could void the user’s authority to operate the equipment. To 

comply with the FCC RF exposure compliance requirements, this device and its antenna must not be co-located or operating to 

conjunction with any other antenna or transmitter.Note: This equipment has been tested and found to comply with the limits for a Class 

B Digital Device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no grantee that 

interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more 

of the following measures.(1)Reorient or relocate the receiving antenna. (2)Increase the separation between the equipment and 

receiver.(3)Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.(4)Consult the dealer 

or an experienced radio/TV technician for help.

IC : 4012A-000000TD20U

Operation is subject to the following two conditions.(1)this device may not cause interference, and (2) this device must accept any 

interference, including interference that may cause undesired operation of the device.

To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically 

radiated power (e.i.r.p.) is not more than that permitted for successful communication.

3.5 (88)

1.1 

(28)

7.4 (188)

5.3 (134)

This adjustment is applicable for zone 1 to 3 as a group and 

zone 4 independently. 

There are volume setting from Level 0 to 4. (Default setting for 

zone 1-3 is level 3, for zone 4 is level 4.) 

2 modes can be set according to the application. 

Press switch 2 for 1 time to activate “VOLUME 

ADJUSTMENT MODE” for zone 1-3 or hold switch 2 for 5 

seconds for zone 4. (Power indicator goes OFF and zone 

indicators display the current setting).

RC-20U will automatically return to normal operation status after 5 seconds without 

any operation. (Zone indicators will go OFF and power indicator will remain lit.)

Louder

Press switch 2 to change volume level (Level 4 is the loudest.)

 

Level 0

Level 1

Level 2

Level 3

Level 4

Normal 

Operation Status

RC-20U will automatically return to normal operation status after 5 seconds without 

any operation. (Zone indicators will go OFF and power indicator will remain lit.)

Press switch 2 to change duration time and setting. 

 

NO OUTPUT

1 SEC.

5 SEC.

30 SEC.

60 SEC.

UTILITY

OUTPUT MODE

Normal

Operation 

Status

Utility Output mode

Regular mode

Zone 1 Chime tone 1

Terminal output

(Time duration according to setting)

Continuous tone and terminal output

(Latches until switch 2 is presses to inactivate.)

Note: Time of the chime will not change according to terminal output 

          duration adjustment.

Chime tone 2

Chime tone 3

Zone 2

Zone 3
Zone 4

Zone 1 Chime tone 1

No terminal output
Terminal output for only 5 sec.

Continuous tone and terminal output

(Latches until switch 2 is presses to inactivate.)

Note: Time of the chime will not change according to terminal output 

          duration adjustment.

Chime tone 2

No chime 

Zone 2

Zone 3
Zone 4

Press switch 1 twice within 2 seconds to activate 

“TERMINAL OUTPUT DURATION MODE” (zone 

indicators display the current setting).

Zone indicator start slow flashing and sound a chime 

followed by 2 beeps whenever the corresponding 

transmitters have low battery. Any operation cannot be 

done until one of operations below are conducted.

 1) Replace transmitter’s batteries. 

 2) Press switch 2. 

RC-20U will not need to relearn transmitter after replacing 

the batteries.

Note:

 Check low battery status at the corresponding

transmitter in case several units are learned in 1 channel.

 