Accessories : 9V layer-built alkaline dry battery (1 piece : Trial use only)
Quick Reference Card, Instruction Manual (this book)
Option : Black tape
* IP67 :  It indicates a level of the protection structure of the product against water and dust under specified

conditions.  This protection structure is in accordance with the standards of IEC (International
Electrotechnical Commission), JIS (Japanese Industrial Standards) and JEMA (The Japan Electrical
Manufacturers' Association).

Specifications may change without prior notice.

Specifications

5

Model

PT-5LD

Measurement range

 500 ˚C

Display range

–10 

 650 ˚C

Field of view

φ

25 / 300mm (D : S=15 : 1)

Optics

mirror / silicon filter

Sensing element

Thermopile

Spectral response

8–14 

µ

 m

Response time

0.7 sec. / 90%

Accuracy (

 

ε

0.95)

0

〜 200

 ˚C : 

2 ˚C ,  201 ˚C

 : 

1 %

 Repeatability

1 ˚C of reading value

Display resolution

1˚C

Sighting method

Non-coaxial laser marker (Class 2)

HOLD time

15 seconds

Continuous measurement mode

ON / OFF Switchable

Memory

99-point memory

High / Low Limit Temp. for Alarm LED / Buzzer

ON / OFF Switchable

Emissivity(

 ε 

) Adjustment

DARK(

 ε 

=0.95) / BRIGHT(

 

0.70) Switchable

Temperature unit

˚C /˚F (Switchable)

Power supply

9V layer-built alkaline dry battery (1 piece)

Battery life

12 Hours (With max load)

Ambient temperature

0 to 50 ˚C

Ambient humidity

35% to 85%Rh (Without due condensation)

Storage temperature

–10 to 60 ˚C

Protective structure

* IP67

Material

ABS (Antibacterial)

Dimension

H x W x D = 160 x 44 x 42mm

Weight

200g (Incl. Battery)

Ramco National

800-280-6933 | [email protected] www.optex-ramco.com

All manuals and user guides at all-guides.com

Содержание PT-5LD

Страница 1: ...81 77 579 8199 Take Care of the Environmet This manual uses recycled paper Printed in JAPAN 1023 3 2008 2 Portable Non Contact Thermometer Instruction Manual Ramco National 800 280 6933 nsales ramcoi...

Страница 2: ...ce of an object into temperature This thermometer measures the surface temperature of solid and liquid without contacting them The temperature of gas cannot be measured by this thermom eter Contents I...

Страница 3: ...s other than those specified herein may result in hazardous radiation exposure Safe Usage This instruction manual contains various warnings for your safety and proper usage to avoid possible personal...

Страница 4: ...thermometer s sensitiv ity to emissivity is fixed at 0 95 0 70 the displayed temperature could differ from the actual temperature of objects which has different emissivity value See Emissivity on pag...

Страница 5: ...opile Spectral response 8 14 m Response time 0 7 sec 90 Accuracy 0 95 0 200 C 2 C 201 C 1 Repeatability 1 C of reading value Display resolution 1 C Sighting method Non coaxial laser marker Class 2 HOL...

Страница 6: ...on wakes up the thermometer The power supply turns off automatically after 15 seconds absence of pressing any button Name of Components 6 Ramco National 800 280 6933 nsales ramcoi com www optex ramco...

Страница 7: ...7 Ramco National 800 280 6933 nsales ramcoi com www optex ramco com All manuals and user guides at all guides com...

Страница 8: ...AX MIN HOLD See Setting on page 15 Continuous Measurement Starting Continuous Measurement qPress and hold both of MEASURE button and SET ENTER button simultaneously for two seconds or more then the Co...

Страница 9: ...cle However please note that the measuring field of view enlarges in proportion to the measuring distance This thermometer has an optical resolution of 15 1 D Distance to the measuring object S Spot s...

Страница 10: ...or more in HOLD Mode refer to page 8 and CALL sign appears on the LCD display In CALL recalling mode the last record of tem perature data and the corresponding memory number are shown on the display w...

Страница 11: ...each setting is completed it automatically turns to the next setting mode For example when setting of High Limit Temperature for Alarm is completed it comes to the setting mode for Low Limit Temperat...

Страница 12: ...perature than Low LimitTempera ture for Alarm Turning ON OFF Alarm Function qWhen the High Limit Temperature setting is completed the setting mode for ON OFF Alarm Function appears Press or button to...

Страница 13: ...Attention The Low Limit Temperature for Alarm cannot be set at higher temperature than High LimitTempera ture for Alarm Turning ON OFF Alarm Function qWhen the Low Limit Temperature setting is complet...

Страница 14: ...ign on the display and press SET ENTER button Then you can return to the setting mode again Please note that OPTEX is not liable for any loss of data Emissivity Emissivity is a value that indicates th...

Страница 15: ...e field of view Adjust the measuring range referring to Field ofView shown in page 9 Affected by a nearby heating source Block the heating source with a shielding plate or something like that to avoid...

Страница 16: ...spection Re calibration is recommended once a year Ask the distributor where you purchased the unit for details Battery Installing Battery When the battery level indicator shows little electricity lef...