1
ADJUSTMENTS
Dipswitch settings
Area angle adjustment
FLEX EYE angle adjustment
4
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator blinks Green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
WARNING
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
*1 : Activation output shows the status of when FLEX EYE mode is enabled. (Dipswitch 14 is set to "ON".)
*2 : When dipswitch 15 is set to "ON".
NOTE
NOTE
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
CHECKING
Outside of
detection area
Entry
Entry to
4th to 6th row
Entry to
3rd row
Entry to
2nd row
Entry to
FLEX EYE
only
Entry to
FLEX EYE
and
2nd to 4th row
Entry to
BLUEZONE
(
*2)
Power off
Outside of
detection area
Check the operation according to the chart below.
ON
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
Image
Operation
indicator
None
Green
Green
Orange
Red
Red Blinking
Purple
Fast Purple
Blinking
Blue
Activation
output (
*1)
Safety
output
Safety
output
Entry
Image
Operation
indicator
1-2.Area width angle adjustment
The angle of the detection area
can both be moved 7° either left or right in 2 steps.
[m(feet,inch)]
[m(feet,inch)]
1-1.Area depth angle adjustment
Left
Right
Deep Shallow
6°×7
6°×7
+2°
-14°
3-1.FLEX EYE width angle adjustment
Make sure to adjust the FLEX EYE angle depending on the door type and the intended touchless plate position
otherwise the sensor may not detect when a hand is approached.
Double slide door
Single slide door
1
2
7
8
Left
eliminated
Right
eliminated
3-2.FLEX EYE depth angle adjustment
After adjusting the angle, make sure that the FLEX EYE is placed on the proper position for your use.
Affix the touchless plate on the appropriate position after adjusting the FLEX EYE.
Make sure to affix the touchless plate where a hand
is not caught by the door during door opening and closing.
CAUTION
Risk of getting caught.
NOTE
NOTE
NOTE
3
Area width adjustment
2
The presence timer is applied to
BLUEZONE(1st row), 2nd row and 3rd row.
The presence timer can be selected
from 4 settings.
When using more than one sensor close
to each other, set the frequency different
for each sensor.
Set the depth rows with dipswitches 6 and 7.
Row adjustment
BLUEZONE
(1st row)
Function
Dipswitch
1
Dipswitch
2
Dipswitch
3
Dipswitch
4
Dipswitch
5
Dipswitch
6
Dipswitch
7
Dipswitch
8
Dipswitch
9
Dipswitch
10
Dipswitch
11
Dipswitch
12
Set the detection area sensitivity according to
the mounting height.
Setting
Comment
Installation mode
Set dipswitch 16 to
"
ON
"
to adjust the 2nd
row. During the installation mode only the
2nd row remains active and the operation
indicator shows yellow. After setting the row
switch dipswitch 16
"
OFF
"
.
Dipswitch
16
Sensitivity
Dipswitch settings table
Presence timer
Frequency
Immunity
Activation output
When dipswitch 15 is set to
"
ON
"
, the
BLUEZONE (1st row) is active and looks
through the threshold.
Adjust sensitivity for FLEX EYE.
Select the FLEX EYE mode "ON" or "OFF".
ON : Activation output is emitted when a
detection occurs in FLEX EYE and the
2nd to 4th row.
OFF : Activation output is emitted when a
detection occurs in the 2nd to 6th row.
3
2
30sec.
3
2
60sec.
3
2
180sec.
600sec.
3
2
A
5
4
B
5
4
C
5
4
D
5
4
6rows
6 7
5rows
6 7
4rows
6 7
3rows
6 7
ON
8
OFF
8
High
1
Low
1
N.C.
9
N.O.
9
Self Monitoring
Disable
10
Enable
10
Safety output
Low
11
High
11
Safety input
Low
12
High
12
Dipswitch
13
FLEX EYE
Sensitivity
High
13
Low
13
Dipswitch
14
Dipswitch
15
FLEX EYE
mode
OFF
14
ON
14
ON
15
OFF
15
ON
16
OFF
16
Set dipswitch 8 to "ON" when the sensor
operates by itself (Ghosting).
Dipswitch 9 is for the Activation output
to door controller.
Dipswitch 11 is for the Safety output
(to door controller).
Dipswitch 12 is for the Safety input
(from door controller).
When the door remains open and the
operation indicator shows Fast/Slow Green
Blinking, refer to
TROUBLESHOOTING
.
If the door still remains open, set dipswitch 10
to "Disable".To comply with EN 16005, set
dipswitch 10 to "Enable".
Area depth adjustment with INFRARED FINDER (Separately available)
INFRARED FINDER
Detection area
Detection area
1.Turn the depth angle adjustment screw to the right (Deep) to place the
detection area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (High) and place it on the floor as shown below.
3. Turn the depth angle adjustment screw to the left (Shallow) until the emitting area is placed at the position where
INFRARED FINDER is in the low detection status (Slow Red Blinking).
REFERENCE
Left
Right
Adjust the detection area width with
the adjustment screws.
When setting the detection area width,
make sure to turn the adjustment screws until it clicks.
cannot be eliminated separately, neither can
7
8
1
2
Make sure that the detection area does not overlap with the door / header, and there is no highly
reflecting object near the detection area otherwise ghosting / signal saturation may occur.
When adjusting the 2nd row close to the door,
see dipswitch 16 in
Dipswitch settings table
and
REFERENCE
for
the easier adjustment.
Deep
Operation
indicator :
Purple
Shallow
High
11
Low
11
ON
ON
OFF
OFF
N.O.
9
N.C.
9
High
11
Low
11
N.O.
9
N.C.
9
Activation
output (
*1)
ON
OFF
After changing the dipswitch settings,
make sure to push the function switch for 2 seconds.
push 2 seconds
[m(feet,inch)]
1
2
3
4 5
6
7
8
Front view
2.0(6
'7")
2.5(8
'2")
2.0
(6
'7")
2.0
(6
'7")
1.0
(3
'3")
1.0
(3
'3")
0
2.0(6
'7")
2.5(8
'2")
3.0
(9
'10")
2.0
(6
'7")
1.0
(3
'3")
0
[m(feet,inch)]
[m(feet,inch)]
2.0(6
'7")
2.5(8
'2")
2.0
(6
'7")
1.0
(3
'3")
-1.0
(3
'3")
0
[m(feet,inch)]
2.0(6
'7")
2.5(8
'2")
2.0
(6
'7")
1.0
(3
'3")
1.0
(3
'3")
0
[m(feet,inch)]
2.0(6
'7")
2.5(8
'2")
2.0
(6
'7")
1.0
(3
'3")
1.0
(3
'3")
0
TROUBLESHOOTING
Deep
-8°
+8°
Shallow
3.5°×2
3.5°×2
Left
Right
* : After changing the dipswitch settings, make sure to push the function switch for 2 seconds.
Unstable
Waterdrops on the detection window.
Use the rain-cover (Separately available).
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Install in a place keeping the waterdrops off.
The detection area overlaps with that of
another
sensor.
Check
ADJUSTMENT 4
dipswitch 4,5.(*)
Check
ADJUSTMENT 4
dipswitch 14.(*)
Check
ADJUSTMENT 4
dipswitch 9,11,12.(*)
Objects that move or emit light in the
detection area.
Remove the objects.
The detection area overlaps with the door/header. Adjust the detection area to "Deep"(Outside).
Sensitivity of detection area is too high.
Set the detection area sensitivity lower.
Wrong wiring or connection failure.
FLEX EYE function is not working.
(Dipswitch 15 is up side position)
Check the wires and connector.
Door operation
Operation
indicator
Possible cause
Possible countermeasures
None
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure.
Check the wires and connector.
Check
ADJUSTMENT 1,2,3
.(*)
Door does not
open when a
person enters the
detection area and
FLEX EYE.
Unstable Wrong detection area(2nd to 4th row) and
FLEX EYE positioning.
Sensitivity of detection area(2nd to 4th row) is
too low.
Set the detection area sensitivity higher.
Short presence timer.
Set the presence timer longer.
Proper
Dirty detection window.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Door opens when
a person enters
the detection area.
Proper
Sensitivity of FLEX EYE is too low.
Set the FLEX EYE sensitivity higher.
Sensitivity of FLEX EYE is too high.
Set the FLEX EYE sensitivity lower.
Proper
Wrong setting of dipswitches.
Sensor failure.
Wrong wiring or connection failure.
Check the wires and connector.
Dirty detection window.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Sensitivity of detection area is too low.
Set the detection area sensitivity higher.
Contact your installer or service engineer.
Door remains
open
Sudden change in the detection area.
Check
ADJUSTMENT 4
dipswitch 1 to 3.(*)
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again.)
Slow
Green
Blinking
Proper
Proper operation
Installation mode is set to "ON".
Set dipswitch 16 to "OFF".(*)
Yellow
Sensitivity of FLEX EYE is too low.
Set the FLEX EYE sensitivity higher.
Slow
Purple
Blinking
Remove highly reflecting objects from the
FLEX EYE. Lower the FLEX EYE sensitivity.
Change the area depth angle for FLEX EYE.
Signal saturation. (FLEX EYE)
FLEX EYE overlaps with the header.
Adjust FLEX EYE to "Deep" (Outside).
Fast
Green
Blinking
Door opens when
no one is in the
detection area.
(Ghosting)
Remove highly reflecting objects from the
detection area. Lower the sensitivity.(*)
Change the area depth angle.
Signal saturation.
(4th, 5th, 6th row and/or BLUEZONE)
Others
Set dipswitch 8 to "ON".(*)
Signal saturation. (2nd and/or 3rd row)
The detection area overlaps with the door/header. Adjust the detection area to "Deep" (Outside).
Slow
Green
Blinking
Remove highly reflecting objects from the
detection area. Lower the sensitivity.(*)
Change the area depth angle.
Setting error.
Red &
Green
Blinking
After changing the dipswitch settings, make
sure to push the function switch for 2 seconds.
OPTEX Co.,LTD.
Manufacturer
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700 FAX.: +81(0)77 579 7030
WEBSITE: www.optex.co.jp/as/eng/index.html
OPTEX Technologies B.V.
European Subsidiary
Henricuskade 17, 2497 NB The Hague, The Netherlands
TEL.: +31(0)70 419 41 00 FAX.: +31(0)70 317 73 21
E-MAIL: [email protected] WEBSITE: www.optex.eu
1.1
(3'7")
0.08
(3")
0.08
(3")
1.1
(3
'7
")