WIRING
2-5
WALL TAMPER (OPTION)
Power wires should not exceed the following lengths.
WIRE GAUGE
HX-40
HX-40AM
HX-40DAM
12 V
14 V
12 V
14 V
12 V
14 V
AWG22 (0.33 mm
2
)
160
(520)
360
(1180)
140
(460)
310
(1020)
120
(390)
250
(820)
AWG20 (0.52 mm
2
)
260
(850)
560
(1840)
230
(750)
490
(1610)
180
(590)
390
(1,280)
AWG18 (0.83 mm
2
)
410
(1350)
900
(2950)
360
(1180)
780
(2560)
290
(950)
630
(2,070)
Universal magnet switch may be mounted as a wall tamper.
Installation space for universal magnet switch is provided on the back of the main unit and the bracket.
Maximum size of an applicable universal magnet switch: D 9 x W 40 x H 9 mm (D 0.35 x W 1.57 x H 0.35 inches)
Universal magnet switch on the market assist is not included.
Bracket
Main unit
9.5-18VDC
+
–
N.C.
COM
N.O.
SP
SP
SP
SP
T.O.(N.C.)
AUX
INPUT
(N.C.)
(N.C.)
(N.C.)
(N.C.)
TAMPER
TAMPER
TROUBLE
OUTPUT
ALARM
N.C.
COM
N.O.
ALARM
POWER
+
–
POWER
AUX
INPUT
9.5-18VDC
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
TAMPER OUTPUT (N.C.) *1
AUX INPUT (N.C.)
TROUBLE OUTPUT (N.C.)
S
PARE (Non short)
ALARM OUTPU
T (N.O.)
ALARM OUTPU
T (COM)
ALARM OUTPU
T (N.C.)
POWER INPU
T (-) (9.5 to 18 VDC)
POWER INPU
T (+) (9.5 to 18 VDC)
HX-40AM
HX-40DAM
HX-40
Magnet switch (Wall side)
installation position
Magnet switch (Base side)
installation position
Wiring Hole
Magnet switch
(Bracket side)
installation position
Magnet switch
(Wall side)
installation position
Unit: m (ft.)
-Installation
1
2
3
Install the other portion of the universal magnet switch to the back of the main unit or the bracket.
Pull the wiring through the knockouts.
When not using the bracket
Fix
In
Wiring sponge pad
Out
When using the bracket
In
Wiring sponge pad
In
In
Tilt the bracket about 45°
and pass through the wire.
Magnet
switch
4
Install the bracket and the main unit to
the wall surface.
5
Connect the universal magnet switch
wiring to the tamper terminal of the main unit.
1
Set the DIP switch 1
(LED ON/OFF) to “ON”.
Note>>
The switch is set “ON” by
factory default.
3
2
Detected
Not detected
Note>>
• For the walk test, move more than 1.0 m
(3.3 ft.) away from the detector.
• Conduct a walk test at least once a year.
Install the universal magnet switch (wall side) to
the wall. To determine the install position, use
the “Install position template” provided on the
inside cover of the product package.
Open the wiring knockout with suitable tool
e.g. screwdriver.
Check that the detector detects an
object in the intended detection area.
The installation has been successful if
the LED lights for two seconds after a
person walks into the detection area.
If the LED indication is not
required at all times, set the DIP
switch 1 (LED ON/ OFF) to
“OFF”.
3
WALK TEST
3
Out
3