background image

 

 

 

 

 

Anti-Tailgate & Anti-Piggyback Sensor System 

 

Model : Control Box A3001CB 

 : 

TOF 

Sensor 

A3001S 

Instruction guide 

(Version 0.01) 

 

 

 

 

Содержание Accurance-3D A3001CB

Страница 1: ...Anti Tailgate Anti Piggyback Sensor System Model Control Box A3001CB TOF Sensor A3001S Instruction guide Version 0 01...

Страница 2: ...n on the power during installation Connect wires into the terminal blocks firmly If the connection is not firm or comes off it may cause a fire Do not use the products beyond the specifications on pow...

Страница 3: ...on the products such as thinner benzine an air freshner or insect spray Inform a building owner or facility manager Inform a building owner or facility manager of the following instruction Warning Ca...

Страница 4: ...e manufacturer and distributors are not liable for any densification by any damages This product may not detect properly an object s under certain specific conditions in case that definitely at the pl...

Страница 5: ...uthorized person is following an authorized person into the Interlock area Piggybacking Unauthorized person is hugging an authorized person or actually on authorized person s back into the Interlock a...

Страница 6: ...case 17 Assembling front case 18 How to mount Control Box 19 2 3 Wiring 20 Wiring example of A3001 20 Input output terminals 21 Wire specification 21 Wiring between Control Box and TOF Sensor 23 2 4 L...

Страница 7: ...ing 40 3 5 Event log recording function 41 Output log delete log 42 3 6 Sound function 43 4 Appendix 44 4 1 Outer dimensions 44 4 2 Specifications 45 Control box 45 TOF sensor 47 4 3 Signal diagram 48...

Страница 8: ...Sensor it can be used for both direction One way only entry and Two way entry and exit The product is designed to register only and therefore not to prevent property loss and casualty or physical dam...

Страница 9: ...power cable Ferrite core 2pcs Wire connector 4pcs Control Box TOF Sensor Magnet contact LAN1 Authorization in Primary Shutdown Zero One More Suspicious AIR Heartbeat Door1 control Door2 control Autho...

Страница 10: ...ary Secondary 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Secondary Activation Activation Zero One More Sus picious AIR Heart beat N A N A Zero One More Sus picious AIR Heart beat N A N A N A Autho rizatio...

Страница 11: ...10 TOF sensor Front side Back side Fig 1 6 Operation indicator 3 colors Power indicator Green Power input socket LAN connector...

Страница 12: ...interlock area as shown as below For One way Interlock area within 1 5 m 1 0 m W D Fig 2 1 Table 2 1 Mounting height 2 3 m 2 6 m 2 9 m A 1 0 m max B 1 5 m max 1 9 m max 2 3 m max C 0 3 to 0 5 m 0 4 t...

Страница 13: ...rea need to be overlapped each other Table 2 2 Mounting height 2 3 m 2 6 m 2 9 m A 1 0 m max B 1 5 m max 1 9 m max 2 3 m max C 0 3 to 0 5 m 0 4 to 0 6 m 0 5 to 0 7 m D C 0 5 m max C 0 6 m max C 0 7 m...

Страница 14: ...1 9 m max 2 3 m max C 0 3 to 0 5 m 0 4 to 0 6 m 0 5 to 0 7 m D 0 3 to 0 5 m 0 4 to 0 6 m 0 5 to 0 7 m E C D 0 5 m max C D 0 6 m max C D 0 7 m max Secured area Non secured area A Entry B E C Authoriza...

Страница 15: ...6 m 2 9 m A 1 0 m max B 1 5 m max 1 9 m max 2 3 m max C 0 3 to 0 5 m 0 4 to 0 6 m 0 5 to 0 7 m D C 0 5 m max C 0 6 m max C 0 7 m max E 0 3 to 0 5 m 0 4 to 0 6 m 0 5 to 0 7 m F E 0 5 m max E 0 6 m max...

Страница 16: ...More person Remove the arrow mark sticker on the front of TOF Sensor after mounting TOF Sensor The sticker blocks the field of view of the TOF Sensor Fig 2 5 Fix TOF Sensor with screws provided Note...

Страница 17: ...g as shown in Fig 2 8 mm Fig 2 8 Note Please mount TOF Sensor under the local law and the local regulations Screw hole 30 Do not put anything Sensing area 139 50 70 50 Screw hole 30 Do not put anythin...

Страница 18: ...17 2 2 Mounting Control Box Disassembling top case Fig 2 9 1 Turning the screw on the upper side of body The screw does not come off Fig 2 10 2 Remove top case as shown in Fig 2 10...

Страница 19: ...18 Assembling front case Front Case can be used in 2 ways by assembly direction Fig 2 11 1 For front wiring Fig 2 12 2 For back wiring...

Страница 20: ...ws or three anchors depending on the mounting wall Fig 2 14 2 Making a hook Make 3mm distance between the screwhead and the wall see Fig 2 14 Fig 2 15 3 Hook the control box on the screw which was mad...

Страница 21: ...ut 24 VDC TOF Sensor Authorization device AIR Sensor Door Access control system or Interlock controller 24 VDC GND Power input Output Primary Operation indicator Primary Secondary 1 2 3 4 5 6 7 8 9 10...

Страница 22: ...ly Sensor Power Cable provided AWG22 LAN Ethernet Cat5e Cable not provided Note LAN Ethernet Cable is not provided Output Primary 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Secondary Activation Activation...

Страница 23: ...ase make a power cable for TOF Sensor from Control Box using addition a cable AWG22 not provided The length of the additional cable should be fitted the distance between Control Box and TOF Sensor Fig...

Страница 24: ...es to back of the TOF Sensor as shown in Fig 2 22 Insert the connectors all the way until the lock is in place To remove connectors pull out cables while pressing the locks Fig 2 23 3 Insert both cabl...

Страница 25: ...g Blue Sensor initialization complete ON Blue TOF system ready to run ON for 2 sec Green Red Blue Operation AIR Detection Blinking Green Non detection ON Green Output Zero ON for 0 2 sec Blue One pers...

Страница 26: ...ting Simultaneous blinking Red Blue Operation AIR Detection Blinking Green Non detection ON Green Output Zero ON for 0 2 sec Blue One person ON for 2 sec Blue More person ON for 2 sec Red Suspicious O...

Страница 27: ...Remote Desktop Connection for settings NOTE Please use more than transmission rate of 1G bps This product has been confirmed to work with Remote Desktop Connection Windows 7 LAN connection In case of...

Страница 28: ...P IP setting of your PC as follows Proxy setting Disable Wired LAN Enable Wireless LAN Disable Notes Only one wired LAN should be used or it may cause problems Firewall Disable Notes The firewall may...

Страница 29: ...rnet view network status and tasks Local Area Connection and show the status of Local Area Connection Click Properties of Local Area Connection Status Select Internet Protocol Version 4 TCP IPv4 of Lo...

Страница 30: ...automatically and Obtain DNS server address automatically of Internet Protocol Version 4 TCP IPv4 Properties and click OK Start up Remote Desktop Connection Click All Programs Accessories Remote Desk...

Страница 31: ...files of Start menu Input 192 168 2 250 to Computer of Remote Desktop Connection and click Connect Select Don t ask me again for connections to this computer and click Yes Input Administrator to User...

Страница 32: ...tion Automatic log on of Remote Desktop Connection Reconnection of Remote Desktop Connection is necessary at the time of setting of the ACCURACE 3D application Performing the following setting is reco...

Страница 33: ...again for connections to this computer and click Connect Input accurance to Administrator Password click OK Remove of Remote Desktop Connection Click X of Remote Desktop Connection in the corner on t...

Страница 34: ...e Date and time can also be changed later After adjusting date and time click OK And click Reboot on the first screen Wait for a while 2 to 3 minutes for Control Box to reboot When set to Automatic Lo...

Страница 35: ...k option as shown in the figure on the below Click Installer Login as shown in the screen on the right After typing the password press OK on the password typing screen After Login Login successful app...

Страница 36: ...of the screen becomes blue and the buttons are added When using two units of TOF Sensor please check that Primary and Secondary are set respectively for each TOF Sensors When not correctly set click...

Страница 37: ...on the floor on the screen as shown in the figure above on the picture I wrote an appropriate detection zone This position can be fine adjusted by using the arrow buttons on the screen Bottom right po...

Страница 38: ...trols are 5 This product has six sensitivity adjustments Volume Moment Low object Sensor Blinding One person and More persons All sensitivity controls have the options of 1 to 9 and the factory settin...

Страница 39: ...imilar Consequence More rejection for person with carrying bag or similar More chance to miss crawling or sneaking entry When Low object rejection occurs Red LED turns on for 2 sec indicating Suspicio...

Страница 40: ...to red It shows the number of authorization Zero One More Sus Each background color is changed by output result It shows the number of output AIR When outputting AIR Detection the background color tur...

Страница 41: ...later One person in interlock Blue 2 sec Blue 2 sec More Start signal 2 sec later Two or more persons in interlock Red 2 sec Red 2 sec Suspicious Start signal 2 sec later Masking against TOF Sensor Bl...

Страница 42: ...when Authorization signal input is received from the Biometric reader or Authorization device in the Interlock When no Authorization signal is received no 3D image data will be recorded For example w...

Страница 43: ...g Select Log Select the output logs to be copied from Files as shown on the screen Connect external memory to USB port on the Control Box After connecting external memory click Search button at Drive...

Страница 44: ...und function When connecting a speaker to the 3 5 mm output mini jack located on the A3001CB you can use the following sounds functions when activated Output Sound One Dingdon More Bzzzzzzz Suspicious...

Страница 45: ...44 4 Appendix 4 1 Outer dimensions Control Box A3001CB mm TOF Sensor A3001S mm 250 91 210 139 50 72 160 50...

Страница 46: ...Basic system Embedded PC Operating system Embedded Windows Start up time 60 to 120 sec ROM Compact flash 2 GByte SSD 120 GB For data storage LAN 1 192 168 1 250 Ethernet Gigabit RJ 45 Fixed IP with DH...

Страница 47: ...condary 9 Zero 10 One 11 More 12 Suspicious 13 AIR 14 Heartbeat 15 16 Dimensions 210 250 91 mm H W D Excluding cables Weight 1 800 g Excluding cables 1 Life expectancy of battery CR2032 to be consider...

Страница 48: ...ck door Detection method Time Of Flight Light source IR LED Image pixels 176 H 132 V Angle of view Horizontal Approx 70 Vertical Approx 55 Mounting height 2 3 to 2 9 m Maximum detection height of pers...

Страница 49: ...signal Power up 60 to 120 sec 1 sec or less Zero One More Suspicious Heartbeat Time Power ON Starting up complete Output Signal Timing Door1 Close Open Close Activation AIR 2 sec 1 sec Zero One More...

Страница 50: ...me Note When a person enters the Interlock and the door remains open for more than one minute this will result in no output signal being generated on the A3000CB and the secondary door will remain loc...

Страница 51: ...ared Check the wiring between Control Box and PC See Wiring between Control Box and PC Check the switch of Control Box is turned on Check the setting of PC See PC Setting TCP IP and PC Setting Remote...

Страница 52: ...y of SSD is full Check the connection of SSD Check the setting of Logging See Output Log Delete Log Delete existing log files Cannot copy Log files External memory device is set Check the connection o...

Страница 53: ...e turn off the power of the Control Box and disassemble wirings 1 Disassemble 5 screws as shown in the figure on the left And take out the cover 2 Next disassemble 8 screws as shown in the figure on t...

Страница 54: ...53 Instruction guide version 0 01 DEC 2015 59 0...

Отзывы: