background image

 

Safety Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

The optical devices used in this equipment are Hazard Level 1M. As required by IEC60825-1, the installer is responsible for insuring that the label 
depicted below is present in the restricted locations where this equipment is installed.  

 

 

 
 
 
This assembly contains parts sensitive to damage by electrostatic discharge (ESD). Use ESD precautionary procedures when 
touching, removing, or inserting parts or assemblies.  

 
 

The DC power input connector serves as a service disconnect for this module. This module is intended for installation in  
locations that provide suitable access to the DC power input connector. 
 
 
 
 
The chassis into which this unit is installed must be housed in a properly rated NEMA enclosure. 
 
 
 
When this unit is operated in extremely elevated temperature conditions, it is possible for internal and external metal        
surfaces to become extremely hot. Care should be taken to insure this unit is installed in a restricted area where only        
properly trained service personnel have access to the unit. 

 

The safety information contained in this section, and on other pages of this manual, must be observed whenever this unit is operated, 
serviced, or repaired. Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of 
design, manufacture, and intended use of the unit. TKH Security Solutions USA assumes no liability for the customer’s failure to comply 
with any of these safety requirements. 

 

SA-1

 

 

LASER RADIATION  

DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MAGNIFIERS) 

CLASS 1M LASER PRODUCT 

WARNING:

 Viewing the laser output with certain optical instruments (for example: eye loupes, magnifiers and 

microscopes) within a distance of 100 mm may pose an eye hazard. 

 

CAUTION:  

DISCONNECTED OPTICAL CONNECTORS MAY EMIT OPTICAL ENERGY.  

DO NOT VIEW BEAM WITH OPTICAL INSTRUMENTS 

 

This product contains Class 1M lasers or LEDs.

   

• Class 1M laser product according to IEC60825-1:1993+A1+A2 
• 

CAUTION: Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.          

• Precautions should be taken to prevent exposure to optical radiation when the unit is removed from its enclosure or when fiber is  
  disconnected from the unit. 
•Laser radiation may be present on a fiber connection to this unit even when the power has been removed from the unit. 
•This unit is intended for installation in locations where only trained service personnel have access to the fiber connections.

  

•The locations of all optical connections are listed in the Connection Locations and Function section of this manual. 
•Optical outputs and wavelengths are listed in the Specifications section of this manual.   

 

Hazard Level 1M 

The border shall be black and the                           
background shall be yellow 

 

   

 

Содержание 9525A

Страница 1: ...Optelecom 9000 Series Installation and Operation Manual Model 9525A Dual Optics RS232 RS422 or RS485 Drop and Insert Modem UM50235 Manual 9525A Rev D...

Страница 2: ......

Страница 3: ...nvironmental Specification 10 1 4 Functional Specifications 11 2 INSTALLATION 13 2 1 System Architecture 13 2 2 Modes of Operation 15 2 3 Operational Features and Considerations 18 2 4 Set Up Procedur...

Страница 4: ...dards of design manufacture and intended use of the unit TKH Security Solutions USA assumes no liability for the customer s failure to comply with any of these safety requirements SA 1 LASER RADIATION...

Страница 5: ...los est ndares de dise o fabricaci n y el uso destinado a la unidad TKH Security Solutions USA no asume ninguna responsabilidad si el cliente no cumple con alguno de estos reequisitos de seguridad SA...

Страница 6: ...Konstruktions und Herstellungsstandards und erfolgt im gegensatz zum vorgesehenen Verwendungszweck dieser einheit TKH Security Solutions USA bernimmt keine Haftung f r das Verabs umnis des Kunden die...

Страница 7: ...eption fabrication et indication d usage de l appareil TKH Security Solutions USA n est pas responsable du non respect de ces consignes de s curite par le client SA 1 RAYONNEMENT LASER NE PAS REGARDER...

Страница 8: ...fiber across and then push it back This will put the dirt that was cleaned off back on again e Repeat the process on a dry folded tissue 3 When removing fibers always clean them when replacing them no...

Страница 9: ...unlimited branches off the main trunk s The units have anti streaming sometimes referred to as anti babbling circuitry for both the optical fiber and electrical RS232 sides On the RS232 side when ena...

Страница 10: ...ng in a System 9000 chassis Model 9000KIT 5 Table 1 Models Available MODELS OPTIC PORT FIBER WAVELENGTH OPTICAL BUDGET 9525A S ST ST 62 5 125 m 850 nm 22 dB 9525A L ST ST 62 5 125 m 1310 nm 21 dB 9525...

Страница 11: ...7 2 k 9 6k 14 4k 19 2k 28 8k 38 4k 57 6k and 115 2k baud auto baud BER 109 or better at the minimum receiver power level Re timing accuracy 0 01 of pulse width for repeated signals Electrical anti str...

Страница 12: ...12 FIGURE 1 MODEL 9525A ENGINEERING VIEWS AND DIMENSIONS...

Страница 13: ...ding on the mode of operation The Model 9525A can be configured into various basic architectures They include a Simple Daisy Chain b Daisy Chain with branches c Fault Tolerant Redundant Ring 2 1 1 Sim...

Страница 14: ...14 FIGURE 2 SIMPLE DAISY CHAIN TRUNKS FROM THE MAIN MASTER WITH EXAMPLES OF BRANCHING USING THE EXPANSION...

Страница 15: ...upted in that direction the modem will automatically select the data from the other direction The master modem also receives data from both directions from each of the local modems and selects the fir...

Страница 16: ...16 FIGURE 3 FAULT TOLERANT RING ARCHITECTURE...

Страница 17: ...is mode is normally used in a network with numerous modems in local daisy chain mode where the master can act at the head of two separate daisy chains or more if the expansion port is used FIGURE 4 IN...

Страница 18: ...ber counter rotating ring In this mode optical data received via both optical ports is selected based on the earliest arrival see Priority Select Section 2 1 4 and routed to the RD output of the data...

Страница 19: ...ser to select among 3 timeouts or to disable the feature The longest timeout selection is sufficient to not trigger an optical side anti streaming timeout for continuous 8 bit ASCII characters quick b...

Страница 20: ...in rudimentary BERT signal generator and detector This feature may be used off line such as in system installation or in a troubleshooting session to quickly indicate the integrity of a transmission p...

Страница 21: ...f the 5 position terminal block will switch the unit to Master mode A low logic level input may be accomplished either by connecting it to the G ground terminal via a switch or by connecting a TTL out...

Страница 22: ...de Anti streaming Enable The optical side anti streaming feature see section 2 3 2 can be enabled or disabled via switch position 4 of the MODES dipswitch It is disabled when the switch is set in the...

Страница 23: ...ains to the ECHO CANCEL Feature and RS485 2 Wire Operation The Ring Propagation Timeout plays a role in the ECHO CANCEL function as explained in Section 2 3 4 This timeout is not important unless the...

Страница 24: ...e the 4 screws holding the surface mounting plate to extrusion Attach the 9000KIT 5 to the unit using the four corner screws that hold the rear panel on the Model 9525A D shell connector end Then atta...

Страница 25: ...nal equipment and the modem are pins 2 Data Input 3 Data Output and 7 Signal Return Common On the modem end however if the Electrical Anti streaming feature is enabled pin 4 RTS must be in a high TRUE...

Страница 26: ...d 9525A must be in RS232 mode and the electrical side anti streaming must be disabled 9525A EXP port 9525A DB25 Port Table 8 RJ12 Expansion Port Pinouts 1 Signal Ground 2 Transmit Data TD Input 3 Rece...

Страница 27: ...ta input to Pin 2 of the Expansion Port RDE GREEN DN Indicates data output from Pin 3 of the Expansion Port TX1 GREEN UP Indicates data being transmitted via the TX1 optical port RX1 GREEN UP Indicate...

Страница 28: ...ng and the BERT LED on the master illuminates it is receiving data that has traveled around the ring To test each ring separately selectively enable the TX11 or TX2 BERT signal outputs and confirm tha...

Страница 29: ......

Страница 30: ...ouda The Netherlands Telephone 31 182 592 333 Fax 31 182 592 123 E mail sales nl tkhsecurity com TKH Security Solutions USA 12920 Cloverleaf Center Drive Germantown Maryland 20874 USA Telephone 1 301...

Отзывы: