Optelecom 9000 Series 
Installation and Operation Manual 

 

Model 9245DT 
Model 9245DR 

 
 

Fiber Optic Video Duplex Data 
Transmitter and Receiver                  
Stand-alone Modules 

 
 

For transport of one NTSC or PAL video signal, 
one duplex RS232, RS422, RS485, or 
Manchester data signal, and two duplex  
Option Module port signals over one optical 
fiber. Digital encoding and transmission 
techniques are utilized for the video (9-bit)  
and the data. 

 

 
 
 

 

 
 
 
 
 
UM50327, Manual 9225D, ECN E08-00190, Rev. H

Содержание 9245DR

Страница 1: ...d Receiver Stand alone Modules For transport of one NTSC or PAL video signal one duplex RS232 RS422 RS485 or Manchester data signal and two duplex Option Module port signals over one optical fiber Digital encoding and transmission techniques are utilized for the video 9 bit and the data UM50327 Manual 9225D ECN E08 00190 Rev H ...

Страница 2: ......

Страница 3: ...curité 7 Fiber Information 8 External Wiring Information 8 Functional Description 9 9245DT Indicator and Connector Locations 10 9245DR Indicator and Connector Locations 12 Set Up and Operation of the 9245DT and 9245DR 14 Troubleshooting 9245D Links 17 Typical Application of the 9245D 17 Specifications for the Model 9245D 18 ...

Страница 4: ...ecaution warning or instruction noted in the manual is in violation of the standards of design manufacture and intended use of the unit TKH Security Solutions USA assumes no liability for the customer s failure to comply with any of these safety requirements SA 1 LASER RADIATION DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS MAGNIFIERS CLASS 1M LASER PRODUCT CAUTION DISCONNECTED OPTICAL CONNECTORS ...

Страница 5: ...ad Si no se cumple con alguna precaución advertencia o instrucción indicada en este manual se infringen los estándares de diseño fabricación y el uso destinado a la unidad TKH Security Solutions USA no asume ninguna responsabilidad si el cliente no cumple con alguno de estos reequisitos de seguridad SA 1 RADIACIÓN LÁSER NO VER DIRECTAMENTE CON INSTRUMENTOS ÓPTICOS DE AUMENTO PRODUCTO LÁSER CLASE 1...

Страница 6: ...tsmassnahmen Warnungen oder Anweisungen in diesem Handbuch nicht befolgt werden verstösst dies gegen die Konstruktions und Herstellungsstandards und erfolgt im gegensatz zum vorgesehenen Verwendungszweck dieser einheit TKH Security Solutions USA übernimmt keine Haftung für das Verabsäumnis des Kunden diese Sicherheitsanforderungen einzuhalten SA 1 LASER STRAHLUNG NICHT DIREKT MIT OPTISCHEN INSTRUM...

Страница 7: ...ion d un avertissement ou d une instruction figurant dans ce manuel est une violation des normes de conception fabrication et indication d usage de l appareil TKH Security Solutions USA n est pas responsable du non respect de ces consignes de sécurite par le client SA 1 RAYONNEMENT LASER NE PAS REGARDER DIRECTEMENT AVEC DES INSTRUMENTS OPTIQUES LOUPES PRODUIT LASER DE CLASSE 1M ATTENTION LES CONNE...

Страница 8: ... fiber across and then push it back This will put the dirt that was cleaned off back on again e Repeat the process on a dry folded tissue 3 When removing fibers always clean them when replacing them no matter how long you had them off 4 When connecting fibers pay attention to the bend radius of the fibers A general rule is to have a 3 inch 8 cm bend radius A bend radius less than 3 inches is an at...

Страница 9: ...RS485 4 wire RS422 or RS232 The data port supports data at speeds up to 115 2 kbps The 9245DT and 9245DR support two TKH Security USA Data Audio Option Modules The modules operate bidirectionally The user may select from duplex audio Option Module type A duplex data Option Module type B duplex contact closure Option Module type C or Stereo Audio Option Module type D Stereo Input and E Stereo Outpu...

Страница 10: ...ATOR This green indicator when illuminated indicates the local unit is in sync with the remote unit and the remote unit is in sync with the local unit 4 SYNC INDICATOR This green LED when illuminated indicates the local unit is in sync with the remote unit 5 PTZ DATA INDICATOR This green LED when flashing indicates the local unit is receiving data from the remote end on the built in data port 6 NO...

Страница 11: ...or Option Module position 2 Refer to the separate Option Module Manual included with your shipment for details on connections to the Option Modules 11 BUILT IN DATA CHANNEL CONNECTOR This is the built in PTZ Data I O connector 12 VIDEO INPUT CONNECTOR This BNC connector is the input for the video signal 13 IEC LASER WARNING LABEL Refer to the Safety Instructions at the beginning of this manual 14 ...

Страница 12: ...3 LOOP INDICATOR This green indicator when illuminated indicates the local unit is in sync with the remote unit and the remote unit is in sync with the local unit 4 SYNC INDICATOR This green LED when illuminated indicates the local unit is in sync with the remote unit 5 PTZ DATA INDICATOR This green LED when flashing indicates the local unit is receiving data from the remote end on the built in da...

Страница 13: ...r Option Module position 2 Refer to the separate Option Module Manual included with your shipment for details on connections to the Option Modules 11 BUILT IN DATA CHANNEL CONNECTOR This is the built in PTZ Data I O connector 12 VIDEO OUTPUT CONNECTOR This BNC connector is the output for the video signal 13 IEC LASER WARNING LABEL Refer to the Safety Instructions at the beginning of this manual 14...

Страница 14: ...for details on the switches and connections for each module type Make the required audio data or contact closure cables to the Option Module connectors and plug the connectors into the Aux Ports on the front panel Connect the video input and output signals Connect the fiber Connect the power input AUX I O PORTS 1 AND 2 OPERATION Aux I O Ports 1 and 2 are supported by TKH Security USA Series Option...

Страница 15: ... 5 6 7 8 9 10 RS232 ON DOWN OFF UP OFF UP OFF UP OFF UP N A N A OFF UP ON DOWN OFF UP RS422 OFF UP OFF UP ON DOWN ON DOWN ON DOWN T T ON DOWN OFF UP ON DOWN RS485 2 Wire ON DOWN ON DOWN OFF UP ON DOWN ON DOWN T T ON DOWN OFF UP ON DOWN RS485 4 Wire OFF UP ON DOWN OFF UP ON DOWN ON DOWN T T ON DOWN OFF UP ON DOWN Manchester ON DOWN ON DOWN ON DOWN OFF UP OFF UP T T ON DOWN OFF UP ON DOWN Disabled O...

Страница 16: ...16 Input connections are made in the following manner FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 ...

Страница 17: ...not receiving sufficient optical signal from the remote unit or the local demux circuitry is not able to synchronize to the incoming signal Check the fiber for poor connections or optical losses greater than the unit specifications Yellow SYNC NO LOOP indicates the local unit has synchronized to the incoming signal but the remote unit has not synchronized with the local unit Check the fiber for po...

Страница 18: ...22 23 Rcvr Opt Budget Rcvr Out Pwr Txmtr Input Sens dB 13 17 23 23 23 Estimated Distance km 50 m 3 N A 19 N A N A Estimated Distance km 62 5 m N A 4 6 N A 19 N A Estimated Distance km 09 m N A N A N A N A 57 1 Range estimates based on fiber losses of 3 0 dB km 850 nm and 1 0 dB km 1310 nm and 1550 nm on 62 5 125 fiber 0 35 dB km 1310 nm and 0 25 dB km 1550 nm on 09 125 fiber and include a 3 dB saf...

Страница 19: ...s POWER Requirements 8 to 15 VDC 9225DR 370 mA 9 VDC 360 mA 12 VDC 350 mA 15 VDC PHYSICAL Dimensions in inches 1 6 H x 3 2 W x 5 0 D ENVIRONMENTAL Operating Temperature 40 C to 74 C Storage Temperature 55 C to 85 C Relative Humidity 0 to 95 noncondensing For installation in outdoor or hazardous locations this unit should be housed in a properly rated NEMA enclosure ...

Страница 20: ...20 MECHANICAL ...

Страница 21: ......

Страница 22: ...Gouda The Netherlands Telephone 31 182 592 333 Fax 31 182 592 123 E mail sales nl tkhsecurity com TKH Security Solutions USA 12920 Cloverleaf Center Drive Germantown Maryland 20874 USA Telephone 1 301 444 2200 Toll Free 1 800 293 4237 Fax 1 301 444 2299 E mail sales us tkhsecurity com ...