4.  

General description  

RFX

   sensor

 

 

5.  

General Technical Data

 

  

 

Dual  Technology 

 

: Active Infrared (950 nm) and Passive Infrared (5 ÷ 12) μm. 

Covered  Area  

 

: 1.3 x 2.2 Meters (Width x Height) 

Operating Angle 

 

: ± 50 ° x ± 4 ° (Lateral x Depth) 

 
Tamper proof   

 

: With Tamper on Front  cover 

PIR Anti-Masking Protec. 

: I.R. Active beam on Lens P.I.R 

Anti-remove  protection 

: REED contact with MAGNET (on duty) 

 
Temperature compensation  : on Digital  P.I.R. 

 

6.  

Other datas

  

 
Power supply        

     

:  12 Vdc  – 30 mA 

 
Trigger time  

 

     

:   

0,2

  Secondi 

Turn ON  time   

     

≥ 2  

 Secondi 

 
Outputs Alarm / Tamper proof   :  Solid state N.C.  contacts (max 100 mA) 
 
Temperature operating      

 : 

- 25

 / 

+ 50

C

  Ambient  

IP  grade  

 

     

 :  IP 

30 (

it can operate outside

  

but it must be protected from direct rain)

 

 
Dimensions 

 

    

 : (

210 x 40 x 40

) mm.  Lenght x Width x Height   

Weight   

 

     

:  

0,15  

Kg.  

 
 
 
 
 
 
 
 
 
 
 

 

         

  Order  codes 

 

       

Description             

 

 

  RFX   B                     

Reflex Sensor at 12 Vdc  for doors and windows  WHITE

 

 

  

RFX   M                    

Reflex Sensor at 12 Vdc  for doors and windows  BROWN

 

   

 

 

The dual-technology RFX  sensor , exploits the benefits of active infrared technology, which allows 
you to generate a signal and synchronously detect changes and passive infrared technology that is 
useful for detecting "hot moving bodies" and helps to discriminate things from people / animals. 
ACTIVE technology generates a very narrow infrared beam that limits the detection range to the 
minimum necessary avoiding FALSE INTERVENTIONS that characterize other technologies that 
fail  to  "delimit"  equally  easily  the  range  of  action.  The  ACTIVE  part  is  also  able  to  adjust  the 
sensitivity of the intervention, so you can exclude pets from the detection. The PASSIVA part is 
equipped  with  a  CUSTOM  fresnell  lens  that  accepts  very  close  intervention  fields.  The  lens  is 
protected against masking with both SPRAY and adhesive tape. Every attempt to mask the lens , 
creates  the  OPENING  of  the  TAMPER  contact  also  if  the  alarm  system  off,  the  attempted 
MASKING is promptly acknowledged. The merging of these 2 technologies has allowed to create 
a SENSOR with HIGH STABILITY OPERATION and with a narrow field of intervention . (Tent 
effect).

 

Содержание RFX B

Страница 1: ...ive Infrared Passive Infrared Alarm and Tamper Outputs by solid state relays N C RFX B M CURTAIN SENSOR USER MANUAL OPTEA s r l Via Saragat 14 40062 Molinella BO ITALY Tel 39 051 665 00 71 Fax 39 051 665 00 28 Siti internet www optea it www optea lift com ...

Страница 2: ...he wall at 1 cm to Sx or Dx from the center of the long side of the sensor by making an hole by the drill c Put anti remove jumper onto ON if the magnet is plugged in otherwise in OFF position no Anti remove function setted d Fix the SENSOR using the 2 dowells supplied of 5mm by the 2 holes on the sensor sides e Connect Tamper and Alarm OUTPUT N C contacts and the power supply 12V GND f Close the ...

Страница 3: ...he button the Red LED starts to BLINK release the button after the desired number of flashes THEN the setted number of flashes it is repeated then pressing again the PROG button starts to BLINK the Yellow LED release the button after the desired number of flashes then the setted number of flashes it is repeated b From 1 to 10 more flashes correspond to a lower SENSITIVITY c At the end of the setti...

Страница 4: ...logy RFX sensor exploits the benefits of active infrared technology which allows you to generate a signal and synchronously detect changes and passive infrared technology that is useful for detecting hot moving bodies and helps to discriminate things from people animals ACTIVE technology generates a very narrow infrared beam that limits the detection range to the minimum necessary avoiding FALSE I...

Отзывы: