RFX   sensor  board  disposition    

 

 
 

 
 
 
 

 

 

 

 

 

 

 
 
 

 
 
 
 
 

PROG   Key 

       1.    

Mounting and wiring the RFX sensor

 

 

 

 

6. TMP  N.C. 
5. TMP  N.C. 
4. ALM  N.C 
3. ALM  N.C. 
2. GND (0V) 
1. + 12 Vcc 

a) Place the sensor at the center of the HIGH side of the area to be PROTECTED 
                 (between Window and roller shutter or immediately outside the roller shutter) 
 
b) Fix the MAGNET in the wall at 1 cm. to Sx or Dx from the center of the long       side of the  
    sensor  by making an hole by the drill .  
   
c) Put anti-remove  jumper onto ON if the magnet is plugged in ,  otherwise in OFF position 
    (no Anti-remove  function setted) 
 
d) Fix the SENSOR using the 2  dowells supplied  of  5mm. by the 2 holes on the sensor sides 
 
e) Connect  Tamper and Alarm OUTPUT (N.C.) contacts and the power supply (+ 12V / GND) 
 
f) Close the sensor cover and lock it with the screw in the center and put the screw cover  
 
g)  Make  some  passages trought  the gateway  to verify its operation

 

  ON       OFF  

Red  

Yellow 

Содержание RFX B

Страница 1: ...ive Infrared Passive Infrared Alarm and Tamper Outputs by solid state relays N C RFX B M CURTAIN SENSOR USER MANUAL OPTEA s r l Via Saragat 14 40062 Molinella BO ITALY Tel 39 051 665 00 71 Fax 39 051 665 00 28 Siti internet www optea it www optea lift com ...

Страница 2: ...he wall at 1 cm to Sx or Dx from the center of the long side of the sensor by making an hole by the drill c Put anti remove jumper onto ON if the magnet is plugged in otherwise in OFF position no Anti remove function setted d Fix the SENSOR using the 2 dowells supplied of 5mm by the 2 holes on the sensor sides e Connect Tamper and Alarm OUTPUT N C contacts and the power supply 12V GND f Close the ...

Страница 3: ...he button the Red LED starts to BLINK release the button after the desired number of flashes THEN the setted number of flashes it is repeated then pressing again the PROG button starts to BLINK the Yellow LED release the button after the desired number of flashes then the setted number of flashes it is repeated b From 1 to 10 more flashes correspond to a lower SENSITIVITY c At the end of the setti...

Страница 4: ...logy RFX sensor exploits the benefits of active infrared technology which allows you to generate a signal and synchronously detect changes and passive infrared technology that is useful for detecting hot moving bodies and helps to discriminate things from people animals ACTIVE technology generates a very narrow infrared beam that limits the detection range to the minimum necessary avoiding FALSE I...

Отзывы: