background image

Hot Water Boiler Manual – Models H 635, H 650 

22 

 

 

List of organizations servicing the solid fuel boilers 

 

 

 

 

 

 

 

 

 

1 M V T - Tomášek - Pekárenská 109 - Trhové Sviny T. 386 322936 - 602 474189 

Č. BUDĚJOVICE 

2 KTK KOVOSTAV - Jar. Kratochvíl - Svatokřížská 37 - Ronov nad Doubravou  T 469 690417 

ČÁSLAV 

3 Montážní Domažlická - Horáček - Janáčková 490  - T 379 724011- 602 882440 

DOMAŹLICE 

4 Václav Klejšmíd - Poděbradova 1170- Dvůr Králové  T 499 620626  - 603 868404-5 

DVŮR KRÁLOVÉ 

5 THERMONA KRKONOŠE  - M. Polák - U pivovaru 123  - T 499 440329 - 604 731000 

RUDNÍK u VRCHLABÍ 

6 THERMONA KRKONOŠE  - M. Hronek - U pivovaru 123 - T 499 440329 - 604 861368 

RUDNÍK u VRCHLABÍ 

7 INSTALATERSTVÍ - M. Svítil - Přemyslova 225 - T 495 264323 - 736 247480 

HRADEC KRÁLOVÉ 

8 Oldřich Horáček - Loudátová 245  - Chrastava   T 485 143001 - 777 720232 

HRÁDEK nad NISOU 

9 PROGRES - Luboš Birner - P. Bezruče 9 - T 379 422705, 602 429117 

 

HORŠOVSKÝ Týn 

10 Oskar Schovánek - Jílové u Držkova 109    T 608 807041 

 

 

Železný  Brod 

11 I T P - p. Zeman - Bavlnářská 360 - Semily T 481 622265 - 606 613964 

 

JIČÍN 

12 Vodoinstalaterství Zd. Vodseďálek - Kněžnice 30 - Libuň  T 493 591097- 732 254748 

JIČÍN 

13 HRON - Zdeněk a Miloš Hronovi - Krajířova 23/1 Dačice T 384 423003 

 

JINDŘICHŮV HRADEC 

14 ÍNPROS - Slavík - Klenovice 174 - Soběslav  T 381 521476 - 603 572515 

 

JINDŘICHŮV HRADEC 

15 Antonín Škvařil - Jakuba Jelínka 385 - T 565 434029 - 728 080497 

 

KAMEN. nad LIPOU  

16 Böse Frant. THERMOMONT - Jáchymovská 89 - T 353 222545 - 604 212400 

KARL. VARY 

17 INTOP - Jaroslav Abík - Poláková 84 - Zásmuky T 321 796129 - 603 451265, 603 451261 

KOLÍN 3 

18 KINTOP - Pavel Měchýř - Nerudova 407 - T 321 728552 

 

 

KOLÍN 3 

19 TEVORS - Novotný - Česká 190 - T 327 514402  777 870060 

 

KUTNÁ  HORA 

20 Jan Šneiberk - Vyhlídková 311      T 485 133564 - 603 257639 

 

LIBEREC 

21 Mačkal Topení-voda-plyn  Wolkerova 441 -  T 58 5341826  603 993849 

 

LITOVEL 

22 Kučmín Josef - Měník 3 - Bíla Lhota  T 58 5340503 - 737 583317 

 

LITOVEL 

23 Svoboda Jiří - Havlíčková 996 - T 326 323779, 604 942834 

 

 

MLADÁ BOLESLAV 

24 Mixed Velebudice - Stavbařů 39 - T 476 709124 - fax.476 703419 - 777 283460 

MOST 

25 SINTOP - Jiří Řezníček - Jirásková 599 - T 495 493693 - 491684 - 603 220057  

Nový Bydžov 

26 Vladimír Ficenec - Půlická 953 - Dobruška  T 494 623310- 605 169324    

 

NÁCHOD 

27 František Kubálek - Zabrdovice 22 - Křinec  T 325 588264 - 724 180739 

 

NYMBURK 

28 TECHMONT - Jaroslav Novák - Dražkovice 58 - T 466 612218 

 

PARDUBICE 

29 Vlastimil Antoš - U pošty 53 Choltice  - T 466 972625 - 603-313991  

 

PARDUBICE 

31 Václav Brábník - Naklov 8 - poš.Lišťany  T 377 915314 - 723 652300 

 

PLZEŇ 

32 TEZA - Šedivý - Pražská 346 - Hořovice 268 01 - T 311 513881 - 603 439354 

PŘÍBRAM 

33 TOPPLAST - Vladimír Blecha - Rpety 3 - Hořovice  T 311 514334 - 603 766102 

PŘÍBRAM 

34 Václav Calta - Panská Tisovice 45 - Petrovice T - 603 213176  

 

PŘÍBRAM 

35 Votoka-Plast  Na čihadle 983 - Dobříš  T 318 523269 - 723 280124 

 

PŘÍBRAM 

36 Kokta - Smečenská 22 - Slaný T 312 521001 - 602 347842 

 

 

SLANÝ 

37 Petr Ditrich - Komenského 36 - T 312 520909 - 606 634043 

 

 

SLANÝ 

38 Jiří  Novotný - Korouhev 195 - T 606 143336  

 

 

 

SVITAVY 

39 Vodo-topo-plyn - Paclík - Borová 7 - T 461 746164 - 603 560070 

 

SVITAVY 

40 ENTES Consulting - 8. Května 41A - Šumperk - T 583 213407 

 

ŠUMPERK 

41 TOPEN - Ladislav Sobotka - Obránců Míru 454 - T 568 824364 - 607 940561 

TŘEBÍČ 

42 Herbert Baumgartl - Petrovice 20 - Dolní Čermná T 465 393197 - 603 818326 

ÚSTÍ nad ORLICÍ 

43 Teplo - Heranova 76 - T 465 521065  

 

 

 

ÚSTÍ nad ORLICÍ 

 

František Adam - Zámecká 1497 - Vlašim - T 317 845039, 607 619930 

 

VLAŠIM 

44 ZOS Tvrdoň Josef - Cihelny 228 - Kelč  T 571 641428 

 

 

VSETÍN 

45 Kovo Zdice - František Johan - Komenského 59 - Zdice  T 311 685383, 602 625750 

ZDICE 

46 Jaroslav  Cígl - Karla IV. - Žatec - T 415 712148 - 608 952233 

 

ŽATEC 

47 Josef Keprta - Lišnice 110  T 465 612395 - 603 311521 

 

 

ŽAMBERK 

48 I W A - Jan Slanina - Brněnská 758 - Žďár nad Sázavou  T 566 299101 - 737 288277 

ŽĎÁR nad SÁZAVOU 

 

Содержание H 635

Страница 1: ...ting of supplied accessories 4 E Listing of replaceable spare parts 4 F Instructions for use 5 G Maintaining the boiler and heating equipment 6 H Safety instructions for installing and using the boile...

Страница 2: ...y effect considerably g The large volume ashtray compartment allows a long term operation with no need of the frequent ash removal B Technical description The boiler the height of which is 1 606 mm fo...

Страница 3: ...l Parameter Unit H 635 H 650 Operating flue mbar 0 25 0 3 Water volume l 80 110 Smoke flue diameter mm 160 160 Hydraulic loss of the boiler T 20 10 mbar 0 7 0 2 0 07 0 2 Boiler class 1 1 Burning time...

Страница 4: ...7 Instruction manual E Listing of replaceable spare parts Component Pieces 1 Cleaning door 1 pc 2 Refueling door 1 pc 3 Ash tray door 1 pc 4 Firing flap 1 pc 5 Underburning through burning flap 1 pc 6...

Страница 5: ...er ignition Add wood and other fuel as needed until the fuel level exceeds the lower edge of the underburning partition Then charge such quantity of fuel which will fill the charging shaft up to the l...

Страница 6: ...r using scraper Impurities fall through the rear section of segments onto the fire bridge From there they move through the burning shaft into the ashtray compartment This shaft can be cleaned through...

Страница 7: ...release Individual pipes of the smoke flue shall be slid into each other with at last 80 mm overlap We recommend that the distance from the boiler to the chimney be less or equal to 1 m The smoke flu...

Страница 8: ...appliance shall be used in compliance with instructions provided in this manual The boiler may be left unattended provided that the output is set to a level when overheating of the system cannot occur...

Страница 9: ...Each heating system shall be fitted with at least one safety valve positioned on the discharge pipe or on the boiler and the pressure gauge Location installation and inside diameter of the safety valv...

Страница 10: ...fference determined for steel boilers at 50 kPa P1 Absolute value of the hydrostatic pressure kPa V Increased volume of water in the whole system dm 3 V G v Where G Weight of water in the heating syst...

Страница 11: ...rheating is avoided As soon as water in the boiler cools down the valve starts closing automatically and the cold water supply to the safety exchanger is closed completely after all This activity may...

Страница 12: ...Hot Water Boiler Manual Models H 635 H 650 12 Boiler connection Reservoir for TS 130 Cooling water discharge valve sensor Honeywell TS 130 valve from the cooler...

Страница 13: ...n 4 Firing flap 5 Underburning through burning flap 6 Long fire bar 7 Short fire bar 8 Grate mechanism 9 Long fire bar support 10 Short fire bar support 11 Fire clay panel 12 Ash tray 17 Burner hole p...

Страница 14: ...4 View of the boiler 1 Cleaning door 2 Refueling door 3 Ashtray door 13 Firing flap lever 14 Grate control lever 15 Secondary air lever 16 Firing flap 19 Pressure gauge 20 Filling and discharge valve...

Страница 15: ...on Primary air inlet Primary air Fig 5 Boiler section during firing 1 Open the firing flap 2 The underburning through burning flap can also be set to through burning 3 Set the flap to underburning bef...

Страница 16: ...ion fuel underburning The underburning method is used for the following fuel types Lignite Anthracite Small wooden waste Close the firing flap immediately after a proper burning is obtained and set an...

Страница 17: ...sh as household refuse Metal parts are to be given over in a junk storage place After termination of the product operating life cover and grates shall be liquidated as metal waste insulation material...

Страница 18: ...Phone 420 571 675 589 Fax 420 571 611 225 Shipping date EXW _____________________ Warranty conditions This warranty certificate provides a proof of quality and completeness The manufacturer confirms t...

Страница 19: ...for 60 months from the EXW shipping date This guarantee is subject to the fact that the pressure expansion vessel has not been used in the heating system and leakage was caused by the inferior quality...

Страница 20: ...is impossible to proceed as per point a the manufacturer is entitled to specify the method date and performance of the repair by its service personnel or contractual partner c The user shall allow the...

Страница 21: ...en v hody je pot ebn vyplnit registra n kartu a zaslat ji na na i adresu OPOP spol s r o Obchodn odd len Za ovsk 750 757 01 Vala sk Mezi Po obdr en vypln n ho formul e V m obratem za leme Z kaznickou...

Страница 22: ...441 T 58 5341826 603 993849 LITOVEL 22 Ku m n Josef M n k 3 B la Lhota T 58 5340503 737 583317 LITOVEL 23 Svoboda Ji Havl kov 996 T 326 323779 604 942834 MLAD BOLESLAV 24 Mixed Velebudice Stavba 39 T...

Отзывы: