PRAESIDIO
®
|
Instruction manual
32
11. Risks and Troubleshooting
11. Risks and Troubleshooting
Characteristic
1.|
The appliance seems to
function normally but no
medium penetrates.
2.|
The appliance doses too much or
not enough medium
3.|
The appliance doesn' t dose
Possible cause
|
No receptacle is inserted.
|
No pump is installed.
|
Appliance is not closed
|
Pump is clogged.
|
Receptacle is empty.
|
Pump is not touched for operation or lost
contact to the medium.
|
An unsuitable medium has been used.
|
Dosage adjustment is not adjusted
correctly.
|
Batteries are empty
|
Power supply has not been connected
correctly.
|
Batteries have not been inserted correctly.
Solution
|
Insert full receptacle.
|
Insert pump into the dispenser.
|
Close the appliance
|
Remove pump and clean it.
|
Replace receptacle.
|
Carry out the dosage process several
times. If it doesn’t function, the pump
is possibly clogged.
|
Use another medium.
Clean the pump thoroughly before.
|
Carry out dosage adjustment
on the pump
|
Insert new batteries.
|
Check the connections
|
Pay attention to the polarity
If the appliance malfunctions, please remove batteries or unplug it from the mains.