Opera ECLIPSE AUTO Скачать руководство пользователя страница 17

 

operabeds.com

  |  

0333 222 8584

  |  

16

15. Product Specifications

System Name

Eclipse Auto Air Mattress System

Power Unit (Air Pump) Model

SR366

Mattress Dimension

2000 x 900 x 200mm (8” depth)

2000 x 1050 x 200mm (8” depth)

Number of Air Cells

20 Cells

Power Control Unit 

Dimension

295 x 225 x 120mm

Material

Power Unit - Plastic Case rated UL 94V-0

Mattress Cell - 100% nylon with TPU lamination

Coverlet - Quilted Nylontaffeta Backing

Power Input

220 - 240Vac, 50Hz, 0.2A

Power Consumption

Normal Operation: Max 20W

Power Control Unit Weight

2.5 kg

Fuse Rating

T1A 250V

Electrical Classification

Class II Type BF applied part mattress.

IP Code

IP21

Operation Mode

This system is not AP/APG Protected.

Continuous operation.

Power Cord Set

H105VV-F or H05VVH2-F,

2 x Min. 075mm2, 250Vac

Operating Conditions

Temperature: 5°C - 40°C

Humidity: 15% - 90%

Atmospheric Pressure: 700 - 1060hPA

Transportation & Storage 

Conditions

Temperature: -25°C - 70°C

Humidity: 0% - 90%

NiMH Battery

3.6Vdc 600mAh

IEC/EN Test Standards 

Safety: IEC/EN 60601-1_v3.1

EMC: IEC/EN 60601-1-2_v4

Maximum Weight Capacity

200 kg

Содержание ECLIPSE AUTO

Страница 1: ...ctions and Technical Specifications V I S I T O P E R A B E D S C O M C A L L 0 3 3 3 2 2 2 8 5 8 4 Enhancing Lives Delivering Comfort O P E R A I M P U L S E A U T O H Y B R I D M A T T R E S S S Y S...

Страница 2: ...autions 4 3 Warnings 5 4 System Package 6 5 Power Unit Features 7 6 Mattress and Power Unit Installations 9 7 Program Settings 10 8 Patient Transfer and Transport 11 9 Emergency CPR Deflation 11 10 Cl...

Страница 3: ...ecubitus mattress replacement system Please read these instructions carefully before setting up and using the device Pay special attention to the warnings and other safety information Use of genuine c...

Страница 4: ...he European Medical Device Directives 93 42 EEC amended by 2007 47 EC IP21 Protected against ingress of solid foreign objects 12 5mm diameter Protected against vertically falling water drops Double In...

Страница 5: ...e layer in order to allow moisture to escape efficiently through the coverlet Breathable incontinent pads are recommended for use with this mattress system 2 3 Flammability Hazard Avoid using this dev...

Страница 6: ...Not Disassemble Do not disassemble the power unit if you are not a qualified technician Please contact Opera on 0333 222 8584 3 3 AP APG Protection This product is not AP APG protected 3 4 Periodic R...

Страница 7: ...Waste Do not fold or bend Not more than two layers should be stacked on top of each other For long term storage the power unit should be in a box or covered with a dust protector 3 10 Disposal of Was...

Страница 8: ...rged The memory re call function recalls the previous setting when the pump is turned off on or after a power outage a b c d b Pressure Monitoring LED Power unit features an integrated pressure sensor...

Страница 9: ...t is not bottoming out f Couplers Quick release female couplers are used to secure mattress air hoses to the power unit g Power Receptacle Insert power cord set firmly into receptacle h e f g e Rocker...

Страница 10: ...Connect Hose Couplers Firmly connect the air hose couplers to the couplers on the power unit Remove existing mattress from the bed frame 6 2 Secure Mattress Replacement 6 6 Power Up Unit Plug the pow...

Страница 11: ...e according to the patient sensation by using the comfort button on the control panel of the power unit If the patient feels the mattress is too soft or firm increase or decrease the mattress internal...

Страница 12: ...unit s power cord from the wall outlet and the mattress should stay inflated for approximately 40 50 minutes This mattress system also has a safety foam base underneath the air cells to support the p...

Страница 13: ...is not properly fitted to the mattress the hybrid alternating pressure cells may move There is also a high risk of cross contamination if the mattress is used without a coverlet Do not use electric o...

Страница 14: ...pera on 0333 222 8584 for assistance Power unit is working but mattress replacement is not inflating and or Bottoming out is occurring and or Patient leaves a deep indentation at the contact area whic...

Страница 15: ...ase inspect all accessories when you purchase our product If there is any damage or missing accessories when you receive the product please ask for a replacement from Opera on 0333 222 8584 within thr...

Страница 16: ...ng of equipment or parts If the damage is a result from improper operation a reasonable service fee and part cost will be charged The warranty stated above is the only warranty made and is in lieu of...

Страница 17: ...put 220 240Vac 50Hz 0 2A Power Consumption Normal Operation Max 20W Power Control Unit Weight 2 5 kg Fuse Rating T1A 250V Electrical Classification Class II Type BF applied part mattress IP Code IP21...

Страница 18: ...17 Opera Beds Opera Impulse Hybrid Mattress System Instructions and Technical Specifications Version 2 Notes...

Страница 19: ...operabeds com 0333 222 8584 18 Notes...

Страница 20: ...Impulse Hybrid Mattress System Instructions and Technical Specifications Version 2 Azure House Connaught Road Kingswood Hull HU7 3AP 0333 222 8584 support operabeds com operabeds com Version 2 Publis...

Отзывы: