background image

controller. 

2. Do not use new battery cells together with run-down cells. 

3. For long time no use, take out the batteries. 

4. To prevent environmental pollution, take out the used batteries and dispose safety and 

appropriately.  

How  to  Use        

To operate the air conditioner, aim the remote controller at the signal receptor. The remote 

controller  will  operate  the  air  conditioner  at  a  distance  of  up  to  7m  (23  feet)  when  pointing  at  

signal  receptor  of  the  air  conditioner.                                                                                                                      

 

 

 

Protection 

Operating condition 

The protective device may trip and stop the appliance in the cases listed below,  

Indoor air temperature is over 43°C 

Cooling 

Room temperature is below 15°C 

Dehumidifying 

Room temperature is below 15°C 

If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when 

relative humidity is over 80%, dew may drip down from the outlet.  

 

Features of protector 

  The protective device will work in the following cases, 

Restarting the unit at once after operation stops or changing mode during operation, you need to wait 3 minutes. 

  If the plug is taken out, when you restart the appliance, it will return to the original mode, TIMER ON and 

TIMER OFF must be set again. 

Drain water 

Special reminder: there is condensing water recycling hidden within this unit. The condensing water is partly 

kept recycling between the condenser and the water tank. When the condensing water level is under the lower 

line, the pump does not work, when it rises to lower line and drive the float switch 1, the water pump begin work 

to recycle the water. When the water level continuously rises to the upper level, the floater switches 2 acts and 

water full indicator (E4) lights on to remind draining water. Please cut off the power supply, move the appliance 

to a suitable place, remove the drain plug, drain water completely. After the drain, re-install the plug, or the 

appliance may leak and make your room wet. If the appliance is placed in a position admitting drain water, you 

also can connect the drain hose to the drain port to drain water. 

 

 

 

 

Maintenance 

Appliance Maintenance 

Содержание MFP35-1280

Страница 1: ...MFP35 1280...

Страница 2: ...To reduce the risk of fire electrical shock or injury when using your air conditioner following these basic precautions 1 Plug into a grounded 3 prong outlet 2 Do not remove ground prong 3 Do not use...

Страница 3: ...utomatic Cool Dehumidify and Fan Mode Control panel opeation Automatic Cool Dehumidifying and Fan Models operation 1 Turn on the unit a Plug in then the unit beeps once b Press the button then the uni...

Страница 4: ...n mode with or 2 When the room temperature the unit will automatically select mode 3 When the room temperature the unit will automatically select mode Mode 1 The up centrifugal fan will run at low spe...

Страница 5: ...s the main control board can memorize the initialization of working mode When you turn on the unit it will work as the same enactment of working mode as last time no need to reset the working mode aga...

Страница 6: ...es Restarting the unit at once after operation stops or changing mode during operation you need to wait 3 minutes If the plug is taken out when you restart the appliance it will return to the original...

Страница 7: ...nly for a half day during a sunny day to dry the appliance inside and prevent from going mouldy 3 Stop the appliance and pull out the power supply plug then take out the batteries of remote controller...

Страница 8: ...down or set temperature reached Restart or wait for auto switch No cold air under COOLING mode Room temperature lower than set temperature 2 Machine enters into anti frost protection 1 This is a norma...

Страница 9: ...not expose the unit under direct sun light o avoid surface colour fading Do not fit the unit for more than 35 or upside down while transporting Place the unit on a flat surface with less than 5 incli...

Страница 10: ...ncy V Hz AC220 240V 50Hz Sounds pressure level dB A 55dB A Net weight kg 30Kg Body mm 400X387X794mm Dimension W x D x H Package mm 585X470X880mm Refrigerant R410a Applying space m 24 29m Miniature fus...

Страница 11: ...tket n verkkovirtaan yhteensopivalla pistokkeella Jos et ole varma onko rakennuksen pistorasiat maadoitettu oikein ota yhteytt s hk teknikkoon Jos virtajohto on vaurioitunut se t ytyy vaihtaa vahinkoj...

Страница 12: ...issa on selitetty siirrett v n ilmastointilaitteen toiminnot Valmiustila Nopeus painike ajastin l mp tila yl s painke Ajastin painike Tila painike ajastin l mp tila alas painike Lepotila painike matal...

Страница 13: ...ja valitsee tai tilan 2 Kun huoneen l mp tila on laite valitsee automaattisesti tilan 3 Kun huoneen l mp tila on laite valitsee automaattisesti tilan tila 1 Keskipakoispuhallin toimii matalalla nopeu...

Страница 14: ...Ohjausyksikk muistaa alunperin asetetun toimintatilan joten kun laite k ynnistet n se on automaattisesti samassa toimintatilassa kuin edellisen k ynnistyksen j lkeen Laitteen toimintatilaa ei tarvitse...

Страница 15: ...lauhduttimen ja vesitankin v lill Kun kondenssiovesi on alarajaa alempana pumppu ei toimi Kun kondenssiveden m r nousee alarajan yli pintakytkin 1 k ynnist kiertovesipumpun Jos veden pinta viel nouse...

Страница 16: ...etken aikaa Onko asetettu l mp tila l hell huoneen l mp tilaa Voit asettaa matalamman l mp tilan Onko puhallusaukko tukossa poista tukos Toimii mutta ei viilenn Onko ovi tai ikkuna auki Onko l hell mu...

Страница 17: ...on laitteen alaosassa Suorista poistoletku ja varmista ett letkun ja oven ikkunan parvekkeen tai muun sein ss olevan aukon v lill ei ole esteit Varmista ett ilman virtausta sis notossa tai ulostulossa...

Страница 18: ...pistokkeesta ennen laitteen puhdistamista huoltamista tai t ytt mist Tekniset tiedot Malli MFP35 1280 J hdytyskapasiteetti Btu h W 12000Btu h 3500W Ilmankuivausteho l h 1 8 l h J hdytys sy tt teho vi...

Отзывы: