6

Place four setting blocks [

H

] in the curb assembly

[

A

] to support the two fixed glass panels [

J

].  Position

the blocks 3" from each corner of the panels.  Remove
any protective strips from the first glass panel and set
it into place on the setting blocks and approximately 
½" into the wall jamb [

E

].  A strip of masking tape ½”

from each vertical edge of the glass will aid alignment.

NOTE:  Obscure glass panels should be installed with
the rough surface of the glass to the exterior of the unit.

Press a 135° post [

K

] into the curb assembly.  It should

overlap the glass panel by ½”.  Use masking tape to
hold the post in position temporarily.  Repeat the glass
and post installation on the opposite panel.

NOTE:  To facilitate out of plumb walls, the ½” glass
bite may be varied from 1/4” to 3/4".

Wipe the shower walls and sill, curb assem-

bly [

A

], and wall jambs [

E

] with a clean, dry cloth

to remove any dust or debris.  Apply a 1/4" bead of
caulk along the inside of both of the pencil lines
marked in Step 

#3

.  Carefully replace the curb in

the exact position marked.  Caulk the inside of the
curb ends where they meet the wall.  Caulk gener-
ously  around  the  anchor  plates  [

B

],  screws  [

C

],

and the inside of the mitered joints.

Replace  both  wall  jambs  and  attach  to  the  wall
with six #8 x 1 1/2" truss head screws [

G

].

5

4

Place the two wall jambs [

E

] into the ends of

the curb assembly [

A

].  Masking tape may be used

to  hold  the  curb  in  place  during  this  operation.
Plumb the jambs and mark the hole locations on
the wall.  Remove all parts and drill the walls for
mounting hardware.

For tile or marble walls, drill six 1/4” diameter
holes  and  insert  the  plastic  wall  anchors  [

F

].

Attachments to fiberglass or acrylic units can be
made in two ways.  If a reinforcement is built into
the  wall  of  unit,  drill  six  1/8"  holes  to  install
mounting screws directly into the reinforcement.
If walls are not reinforced, drill six 1/4” holes and
install plastic wall anchors or toggle bolts (toggle
bolts not supplied by A

LUMAX

).

Page 4 of 8

#8 x 2”

Содержание 394CV

Страница 1: ...394CV Series Neo Angle Shower Enclosure 202 Anderson Ave Belvue KS 66407 Phone 800 669 9867 Fax 800 393 6699 www onyxcollection com 394CV 0120 800 643 1514 www alumaxshowerdoor com...

Страница 2: ...Snap in Fillers 1 Assembled Door Panel 1 Drip Vinyl 1 Door Handle 1 Door Handle Vinyl 8 8 Pcs Vert Glazing Vinyl 72 8 Pcs Horiz Glazing Vinyl 36 394 STIKSTALL PARTS LIST N C CC C C 1 Hinge Jamb Attac...

Страница 3: ...plates as a guide drill matching 1 8 holes into the curbs Secure the anchor plates to the curb assem bly with eight 8 x 1 4 truss head screws C As you tighten the screws be sure the miters are forced...

Страница 4: ...1 4 bead of caulk along the inside of both of the pencil lines marked in Step 3 Carefully replace the curb in the exact position marked Caulk the inside of the curb ends where they meet the wall Caulk...

Страница 5: ...or breakage 8 9 Push the hinge jamb door panel assembly R and the strike jamb N with magneticstrip so they overlap the 135 posts K L N HINGE JAMB DOOR PANEL STRIKE JAMB R Adjust the door panel assemb...

Страница 6: ...tightly against the top and bottom With the hinge jamb plumb and both fillers tight between the two door jambs the strike jamb also will be plumb and parallel to the hinge jamb Attach the strike jamb...

Страница 7: ...then place a Plastic Washer against the glass Place the handle without Set Screws against the Plastic Washer and insert the threaded end of the Cone Head Screw through the bushing into the threaded i...

Страница 8: ...both ends and working toward the middle Be careful not to stretch the vinyl Install the top interior vinyl and the two bottom vinyls in the same way Repeat for the second glass panel Cut eight pieces...