Gain preset
Conditions
A/C AUTO
OFF
A/C SEA
fully clockwise
A/C RAIN
fully counterclockwise
GAIN
fully Clockwise
Scanner
OFF
[INSTALLATION SETUP 1] menu
4. Ant on Tx
:
STOP
Table 3-6 Gain preset
VR1
V
= 0.04 to 0.06V
Check Point
Rating
Adjuster
TP3 on
SPU pcb
(trigger
at TP1)
STC curve
Conditions
A/C SEA
fully clockwise
GAIN
fully Clockwise
Table 3-7 STC curse
TX on 12nm
Check Point
Rating at 60 uS
point
TP4
MED
LOW
HIGH
VR2
3.1
0.1V
3.6
0.2V
2.5
0.2V
Ant Height
on
Installaion Setup menu
Adjuster
60uS
26