Onset, HOBO, HOBOware, and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation. 

DIMENSIONS 

Housing 

 

Bottom View (DIN Mount Configuration) 

 

Bottom View (Screw Mount Configuration) 

 

OPERATION 

The E50B2 DIN Rail Power Meter provides a solution for measuring 
energy data with a single device. Inputs include Control Power, CT, 
and 3-phase voltage. The LCD screen on the faceplate allows instant 
output viewing.  

The meter is housed in a plastic enclosure suitable for installation on 
T35 DIN rail according to EN50022. The E50 can be mounted with 
any orientation over the entire ambient temperature range, either 
on a DIN rail or in a panel. The meter is not sensitive to CT 
orientation to reduce installation errors. 

DATA OUTPUTS 

Native: 

 

Volt Ampere Reactive Hour (VARh) 

 

Watt Hours (Wh) 

 

Ampere Hour (Ah) 

Derived in HOBOware®: 

Derived Channel 

Unit 

Calculation 

Reactive Power 

VAR 

VARh/h 

Volt-Amps 

VA 

SQRT(Wh^2 + VARh^2)/h 

Volts 

SQRT(Wh^2 + VARh^2)/Ah 

Power Factor 

PF 

Wh/SQRT(Wh^2 + VARh^2) 

True Power 

Wh/h 

True Power 

KW 

W/1000 

Kilowatt Hours 

KWh 

Wh/1000 

Amp A 

Ah/h 

(where ‘h’ is hours = Logging Interval/3600) 

PRODUCT DIAGRAM 

 

 

 

www.

.com

[email protected]

1.800.561.8187

Содержание T-VER-E50B2

Страница 1: ...Measurement Accuracy Real Power and Energy IEC 62053 22 Class 0 5S ANSI C12 20 0 5 Reactive Power and Energy IEC 62053 23 Class 2 2 Current 0 4 0 015 per C deviation from 25 C from 5 to 100 of range...

Страница 2: ...e The LCD screen on the faceplate allows instant output viewing The meter is housed in a plastic enclosure suitable for installation on T35 DIN rail according to EN50022 The E50 can be mounted with an...

Страница 3: ...the housing and the screw hole must be exposed on the outside of the housing 2 Use three 8 screws not supplied to mount the meter to the back of the enclosure See diagram of the underside of the meter...

Страница 4: ...arallel wires for control power and voltage inputs The following symbols are used in the wiring diagrams on the following pages Symbol Description Voltage Disconnect Switch Fuse installer is responsib...

Страница 5: ...ation WIRING DIAGRAMS CTs are not polarity sensitive No need to observe orientation Diagram 1 1 Phase Line to Neutral 2 Wire System 1 CT SYSTEM TYPE 1L 1n Diagram 2 1 Phase Line to Line 2 Wire System...

Страница 6: ...C to 347 VAC UL or 300VAC CE Direct Connect Control Power DC Control PowerTransformers CPT Connection DC Control Power from 125VDC to 300VDC UL and CE max The Control Power Transformer may be wired L...

Страница 7: ...mA 50 C The over current protective device must be rated for the short circuit current at the connection point Pulse outputs are only intended to be connected to non hazardous voltage circuits SELV or...

Страница 8: ...SYSTM screen Use or to select the System Type see wiring diagrams on pages 9 10 b back to the S SYS screen 6 Optional to the S PT Set Potential Transformer screen If PTs are not used then skip this st...

Страница 9: ...AC VAB VBC VAC Voltage Line to Line V VLN Voltage Line to Neutral PF PF Power Factor U VLL Voltage Line to Line HZ HZ Frequency kSh kVAh Accumulated Apparent Energy kQh kVARh Accumulated Reactive Ener...

Страница 10: ...on Veris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademar...

Страница 11: ...ris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks of...

Страница 12: ...poration Veris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered tr...

Страница 13: ...emarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation USER...

Страница 14: ...caling is listed below You can also enter custom scaling values in the following increments in both HOBOware and HOBOlink Refer to the HOBOware or HOBOlink help for more details Reactive Energy VARh 1...

Страница 15: ...Usable Pulse Scale Setting for Wh VARh Key 1 Wh per pulse default 10 Wh per pulse 100 Wh per pulse 1 000 Wh per pulse 10 000 Wh per pulse 3 Phase Systems 2 Phase Systems Single Phase Systems Minimum U...

Страница 16: ...eris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks o...

Отзывы: