PROTECTION OF EYES FROM LASER BEAM DURING SERVICING
This set employs a laser. Therefore, be sure to follow
carefully the instructions below when servicing.
WARNING!!
SERVICE WARNING : DO NOT APPROACH THE
LASER EXIT WITH THE EYE TOO CLOSELY.
IN CASE IT IS NECESSARY TO CONFIRM LASER
BEAM EMISSION, BE SURE TO OBSERVE FROM
A DISTANCE OF MORE THAN 30cm FROM THE
SURFACE OF THE OBJECTIVE LENS ON THE
OPTICAL PICKUP BLOCK.
Laser Diode Properties
GaAS/GaAlAs
780 nm
Continuous
MAX. 7 mW
LASER WARNING LABEL
The labels shown below are affixed.
1. Warning label
2. Class 1 label
LUOKAN 1
LASERLAITE
KLASS 1
LASER APPARAT
DANGER:
INVISIBLE LASER RADIATION WHEN OPEN AND
INTERLOCK FAILED OR DEFEATED. AVOID DIRECT
EXPOSURE TO BEAM.
"CLASS 1 LASER
PRODUCT"
CAUTION:
HAZARDOUS LASER AND ELECTROMAGNETIC
RADIATION WHEN OPEN AND INTERLOCK DEFEATED.
ATTENTION:
RAYONNEMENT LASER ET ELECTROMAGNETIQUE
DANGEREUX SI OUVERT AVEC L'ECLENCHEMENT
DE SECURITE ANNULE.
Material:
Wavelength:
Emission Duration:
Laser output:
SERVICE PROCEDURE
1. Replacing the fuses
REF. NO.
PART NO.
DESCRIPTION
F901
252074
2A-SE-EAK, Fuse <GT, GR>
[NOTE ]
<GT> : Asian model
2. To initialize the unit
(1) Connect the power supply cord in the wall socket.
(2) Press the
STANDBY/ON
button to turn the power source on.
(2) While hold down the
YES
button, press the
DISPLAY
button.
(4) Press the
STANDBY/ON
button.
(5) Disconnect the power supply cord.
3. How to reset the unit compulsorily
Used when it becomes impossible to eject a disk.
Continues pressing the
STOP
button more than for 5 seconds.
<GR> : Chinese model