CDR-205TX
ADJUSTMENT PROCEDURES-4
5.3 CD-RW Record Power Adjustment
RW Bias : 2.3 mW
±
0.05 mW, RW REC : 3.2 mW
±
0.05 mW, RW Erase : 5.2 mW
±
0.1 mW
Pickup objective lens
Optimizing CD-RW recording power of laser diode.
Incapable of CD-RW recording, self-pre recorded CD-RW disc playback. Sound
pauses, track jumping, or bad RF wave shape (though no failure in playing CD).
Test Point
Adjustment Value
Purpose
Symptom when Out of Adjustment
Adjustment method
FL Indication
(1) All the reading values of power meter of this adjustment are values with an average.
(2) How to confirm the adjustment value:
When enter the power adjustment mode, enter it by pressing the REC and DISPLAY keys in order.
Furthermore, can confirm the adjustment value of each power stored in EEPROM by switching the DISPLAY key.
However, RW cannot see all adjustment results. Use DAC the same as erase power in the Bias Power Adjustment, and
perform the adjustment of record power while outputting the setting value of erase power decided in the Bias Power
Adjustment. And perform the Erase Power Adjustment while outputting the setting value of the record power.
Therefore, the value of Bias Power Adjustment does not remain after adjustment of the erase power. (as for the displayed
adjustment value, erase power is the same as bias power.)
It is only erase power that can confirm the adjustment result with the power meter among power of RW.
As for the value of Record Power Adjustment, only setting numeric value is readable, but output power becomes the same
as the erase power.
Bias power cannot confirm the setting value, too. Be not used during actual record operations either.
[Procedure]
<Adjustment of CD-RW BIAS Power>
12. Turn the JOG(AMCS) key to adjust the power.
Switch the coarse adjustment and the fine adjustment by pressing the REC key, and adjust it.
(initial state is the coarse adjustment.)
13. Press the PLAY/PAUSE key to register the adjustment if the power became the adjustment value.
When it is registered, shift to the CD-RW Record Power adjustment automatically.
Note:
In the CD-RW Bias Power Adjustment, in the case that the power is over 2.3 mW when the LD
lighted, do not need to perform the Bias Power Adjustment. Set adjustment value of the CD-RW
record power to + 0.9 mW ± 0.05 mW against the power in LD lighting then.
<Adjustment of CD-RW Record Power>
14. Turn the JOG(AMCS) key to adjust the power.
Switch the coarse adjustment and the fine adjustment by pressing the REC key, and adjust it.
(initial state is the coarse adjustment.)
15. Press the PLAY/PAUSE key to register the adjustment if the power became the adjustment value.
When it is registered, shift to the CD-RW Erase Power adjustment automatically.
<Adjustment of CD-RW Erase Power>
16. Turn the JOG(AMCS) key to adjust the power.
Switch the coarse adjustment and the fine adjustment by pressing the REC key, and adjust it.
(initial state is the coarse adjustment.)
17. Press the ENTER key to register the adjustment if the power became the adjustment value.
18. Press the STOP key to goes out the LD, and adjustment is completed.
" RwBIAS_
∗
00XX "
" RwREC_ _
∗
0000 "
" RwREC_ _
∗
0XXX "
" RwERAS_
∗
00XX "
" RwERAS_
∗
0XXX "
" 00000000_ _x1 "
www. xiaoyu163. com