DATA LOGGING
Log Site ID
– Enter a number from 00 (Default) to 99. The Site ID will become
part of the filename for any file downloaded from the FP-4400, to help
distinguish from other installation sites. This parameter can be changed at any
time.
Logging Mode
– Select the logging mode. Default = Flow. Options = Flow,
Velocity. This setting cannot be changed if Data Log = Logging. Either STOP or
DELETE the Data Log to change the Logging Mode.
File Format
– Choose the file format for downloading the log. Default = .LG2.
Options = .LG2, .CSV. LG2 format is used for viewing the logged data with the
free ONICON Logger Software. CSV format is used for importing into spreadsheet
software like Microsoft Excel. This parameter can be changed at any time.
Date
– Select the current Date in MM/DD/YYYY format. It is strongly suggested
that the Data Log is deleted and restarted after changing the Date, Time, and
Interval.
Time
– Select the current Time in HH:MM:SS format. Options: 00:00:00-23:59:59.
It is strongly suggested that the Data Log is deleted and restarted after changing
the Date, Time, and Interval.
Interval
– Select the interval between samples to be stored to the data log.
Smaller intervals provide better resolution and understanding of changes in flow
rate or velocity over time, at the expense of file size and storage capacity. The FP-
4400 has capacity for approximately 3.8 years of continuous logged data at a 10
second interval. Default = 30 sec. Options = 10 sec, 30 sec, 1 min, 2 min, 5 min,
10 min, 15 min, 30 min, and 60 min.
Data Log
– Shows the status of the Data Log, and is used to change the status.
Logging = Data Log is active. Stopped = Data Log is stopped. Delete = deleted
the Data Log and sets the status to Stopped. Start = starts the Data Log and sets
the status to Logging. Stop = stops the Data Log and sets the status to Stopped.
Log In Standby
– Currently not used.
Data Logging
Logging Mode
Log Site ID
File Format
Date
Time
Log in Standby
Interval
Data Log
Flow
00
.LG2
Nov 29/2021
12:50:21
NO
30 sec
Logging
RETRIEVING LOG FILE
Plug a USB-C drive (one is included with the FP-4400) into the USB-C port on the
bottom the electronics enclosure. The display will show a downloading icon, then
a check mark on the icon when the download is complete. When the check mark
appears, the USB-C drive can be removed.
The downloaded file name will appear in this format:
FP-4400__0A.LG2
. The “0”
will change, based on the Log Site ID parameter. The “A” will increment: B, C, etc.;
with each subsequent download of the data log.
IMPORTANT NOTE
Downloading the file in .LG2 format will take approximately 2.75 minutes
each 1% log used. Downloading in .CSV format will take approximately 5.7
minutes each 1% log used.