FP-4400 PORTABLE CLAMP-ON ULTRASONIC FLOW METER
ONICON Incorporated 727.447.6140
Page 19 onicon.com
4.1 KEYPAD
Keypad layout and functionality is as shown and described below:
LEFT Arrow:
•
From Main screen – Navigate to 24 Hr Log page
•
In programming menus – navigate out-of the Main
Menu or sub-menu
•
In pop-out menus – cancel the selection of a parameter.
For numerical entries – moves the cursor left, unless
on the left-most number, which will then cancel the
numerical entry.
UP Arrow:
•
From Main screen – Navigate to Messages page
•
In programming menus – navigate up in the menus
•
In pop-out menus – change the selection or numeric
entry
RIGHT Arrow:
•
From Main screen – Navigate to Main Menu
programming page or Passcode entry
•
In programming menus – navigate into the selected
sub-menus, or bring up a pop-out menu for a parameter
•
In pop-out menus – change the selected number in a
numerical entry
DOWN Arrow:
•
From Main screen – Navigate to Status page
•
In programming menus – navigate down in the menus
•
In pop-out menus – change the selection or numeric
entry
CHECK Button:
•
From Main screen – not applicable
•
In programming menus – will move the cursor back one
level. Example: if in the Units/Mode sub menu, CHECK
will move back to Main Menu.
•
In pop-out menus – confirms the selection of a
parameter or numerical entry.
POWER Button:
•
From Main screen – Press & hold for one second for the
Power Mode selection pop-out. Immediately release to
enter STANDBY mode. Continue holding for POWER OFF.
•
In programming menus – exits to Main screen
•
In pop-out menus – exits to Main screen
98%
0.00
USG/m
0 USG
Total
SECTION 4.0 START-UP