XIV. Filter Efficiency Gauge Mounting Instructions

Mounting Instructions

Gauge Reading Instructions

1. Select a location free from excessive 

vibration and where ambient temperature 

is between 20 F to 120 F (-6.7 C to 49 C). 

You can mount gauge up to 8’ away from 

static pressure tube. Gauge bracket can be 

mounted to stand gusset for easy reading.
2. Mount brass static tube in plenum with tip 

pointed into air stream. Use included mount-

ing bracket and sheet metal screws if interior of 

plenum is not accessible. Refer to the drawings for 

location of brass static pressure tube. Use 13/32” 

drill bit for hole.
3. Put gauge through supplied mounting plate with 

pre-cut 2 5/8” hole. Put the two bolts from gauge 

box through front of gauge. Put metal brace from 

gauge box against plate back with gauge bolts 

through brace to hold gauge tight against plate. Put 

supplied nuts from gauge box on bolts and tighten.
4. Mount plate with gauge to appropriate surface. 

If mounting to stand, user must drill a hole and 

supply hardware attachment. Connect clear tubing 

from brass static pressure tube to port labeled “+” 

on the back of the pressure gauge. Make sure 

tubing is not crushed or kinked along its entire 

length. Cut shorter if necessary.

Before you insert brass static pressure tube, use a marker and 

mark top of brass nut where tube will be in the up position so 

when you position tube or tighten it, you’ll know where tube is 

pointing.

1. Gauge may need to be zeroed. Follow the instructions provided with pressure gauge.
2. Take the initial reading with cleaned filter(s) and the typical number of blast gates 

open in normal operation.
3. Always read the gauge with the same number of gates open. The more gates open, 

the higher the pressure reading on the gauge.

4. When the gauge rises to 3”, it’s time to clean your filter(s).

After many cleaning cycles, a filter’s pressure will rise after each cleaning. 

An older filter does not get as clean as a new filter.

Air Flow to Filter

Metal Plenum

Air Flow to Filter

Silicone

Washer

Up to 8’ 

away

Plastic Plenum

Air Flow to Filter

Gasket

Plate

Mounting Bracket

Drill 13/32” 

hole here.

Either side.

OR

Содержание Pro 1500

Страница 1: ...Owner s Manual 9_11 Oneida Air Systems Inc 1001 West Fayette St Syracuse NY 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Shown with optional Stand Models may vary slight...

Страница 2: ...operating system Proudly Made in the USA I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI XVII XVIII XIX XX 2 3 4 5 6 7 8 9 10 11 11 12 13 14 15 16 17 18 19 20 System Start Up Information Config...

Страница 3: ...well as the recommended safety practices in this manual 3 Motor is pre wired at the factory If magnetic starter trips circuit check the following 1 Dust drum securely fastened to discharge of cone 2 I...

Страница 4: ...8 Shown with optional Stand 3 Pro 1500 2000 O A S 2010 1 External Cartridge Filter Silencer Included with Filter Caution Cartridge Filter Media Pat Pend Flame Guard Arrestor If exhaust air is vented o...

Страница 5: ...r Filter 3hp 80 82 dBA 10 5hp 80 83 dBA 10 35 Gallon Fiber Drum Other Sizes Types Available Cast Aluminum Alloy 356 51 Backward Inclined Non Sparking Non Ferrous as Required by NFPA Fire Code Dynamic...

Страница 6: ...Pro 1500 2000 O A S 2010 5 IV Dimensions For Minimum Mounting Heights w 39 Filter Dimensions subject to slight variation in manufacturing 94 00 7 8 94 00 97 5 6 00 36...

Страница 7: ...ooks 8 AFJ051602 AFT000001 5d Dust Pan FPZ000018 6 7 18 x 36 HEPA Media Filter w Pat Pend Flame Guard Arrestor 5d 5a Plenum FPX000001 3 Cyclone Barrel SXI002109 SCI002309 4 Cyclone Cone SCX012109 SCX0...

Страница 8: ...on the INSIDE of the Fan Housing as shown in diagram 2 Stick the gasket material around the Fan Housing as shown in the diagrams outside of the bolt circle Making sure of a complete seal Dust collecti...

Страница 9: ...nd which direction your ductwork will enter the collector Bolt Fan Blower housing to Cyclone barrel Then bolt Motor and Plate to Fan Blower housing Carefully lay unit on its side and then bolt cone to...

Страница 10: ...wall stud spacing See Fig 1 2 Use a level to ensure straightness 3 Attach bracket to wall with lag screws concrete anchors or other suitable hardware See Fig 2 3 Note When installing the brackets on...

Страница 11: ...id Gussets with 2 1 4 20 x 3 4 bolts and secure with 1 4 Flat Washer and 1 4 20 Nylock Nut Adjust the legs for the 21 or 23 cone by positioning the bolts in the appropriate position in the slotted bra...

Страница 12: ...This allows the lid to move up when installed Cut the hose with razor knife and then cut the wire with diagonal cutters Don t cut too short If in doubt cut a little long Trim if necessary 2 Attach Pl...

Страница 13: ...st bin is in place and ductwork is connected to inlet before turning on the dust collector Electrical Wiring Make sure power source matches wire voltage configurations on motor Prior to connecting to...

Страница 14: ...is trapped inside filter so it will not make a mess Filter must be cleaned regularly or filter damage may result If gauge reaches 3 it is time to clean your fil ter Never allow gauge to reach 5 You co...

Страница 15: ...ace If mounting to stand user must drill a hole and supply hardware attachment Connect clear tubing from brass static pressure tube to port labeled on the back of the pressure gauge Make sure tubing i...

Страница 16: ...h mounting bracket into mounting surface Screw needs to be smaller than Captive Fastener Clean the grease fitting or area around grease hole if equipped with slotted grease screws If motor has a purge...

Страница 17: ...olex on back panel of starter base Start Stop Push Button Assembly on Starter Molex Female Molex at bottom of starter 3 Wire Adapter Molex AMA000000 3 Start Stop AMR220000 YEL YEL YEL YEL Wire Nuts YE...

Страница 18: ...Fiber 55 Gal Fiber 55 Gal Steel The BAG Gripper ABX000000 The BAG Gripper provides the ability to use convenient plastic bags inside your dust drum It provides a Constant negative pressure on the out...

Страница 19: ...eaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check for a restricted pipe too small a...

Страница 20: ...e This exempts some small operators from the NFPA code 664 but other codes may apply in your jurisdiction Consult your local Fire Marshall for help Additional information can be found in NFPA Code Boo...

Страница 21: ...HE USE OF OUR PRODUCT Before Purchasing or Installing a dust collection system the buyer is cautioned to do so in accordance with prescribed Federal State Local OSHA NFPA and any other applicable code...

Отзывы: