background image

NIS54xxGEVB

 

 

http://onsemi.com

 

NIS5431 Overcurrent Protection 

 

 

Continue with jumpers J2 (10 Ω), J1 (5431), J4, J8, and J13.  With VCC set to 3.3 V, press the large green 

button to short circuit the output.  A power supply capable of supplying more than 3 A is recommended.  The 
mechanical switch will bounce, but the eFuse will have no issue responding to this disturbance.  It will respond to 
the fault within 10 μs and the current will be limited to the short circuit current limit level.  After some time the 
device will enter thermal shutdown due to the high current and voltage between VCC and source (output voltage) 
pins.  An auto-retry eFuse (MT2 part number suffix) does not latch and automatically cycles the enable pin.  For 
auto-retry eFuses the demo board’s green and yellow indicator enable pin indicator LEDs will flash as the enable pin 
cycles between states. 
 

 

Figure 6:  This is a demonstration of the current limiting circuit.  The eFuse responds quickly to 
the short circuit event and begins conducting at the short circuit current limit.     

 
 

 
 
 
 
 
 
 
 

 

Содержание NIS54 Series

Страница 1: ...D USER S MANUAL This evaluation board has many features which make it simple to observe the functionality and performance of the new NIS54xx line of eFuses Multiple connectors available for all eFuse...

Страница 2: ...rd The user s manual is divided into two sections The first section is for the NIS5431 3 3 V series of devices The second section covers the NIS545x 5 V series of devices For these devices ensure that...

Страница 3: ...voltage drop of 6 2 V the device will reach its thermal shutdown point and latch off The green indicator LEDs will turn off and the yellow fault indicator LED will be on An auto retry eFuse MT2 part...

Страница 4: ...ly cycles the enable pin For auto retry eFuses the demo board s green and yellow indicator enable pin indicator LEDs will flash as the enable pin cycles between states Figure 5 This test shows how the...

Страница 5: ...will be limited to the short circuit current limit level After some time the device will enter thermal shutdown due to the high current and voltage between VCC and source output voltage pins An auto r...

Страница 6: ...controlled slew rate changes When J6 is in place the slew rate will be longer because a capacitor is connected between the dv dt pin and GND With VCC set to 3 3 V press and release the blue button to...

Страница 7: ...the 3 3 V power cable and plug it into the demo board Observe that the eFuse turns on with no issue and the output voltage rises in a controlled fashion Figure 8 This shows a standard hot plug test Th...

Страница 8: ...ches the thermal shutdown level and latches off An auto retry eFuse MT2 part number suffix does not latch and automatically cycles the enable pin For auto retry eFuses the demo board s green and yello...

Страница 9: ...age drop of 4 V the eFuse will reach its thermal shutdown point and latch off The green indicator LEDs will turn off and the yellow fault indicator LED will be on An auto retry eFuse MT2 part number s...

Страница 10: ...able pin For auto retry eFuses the demo board s green and yellow indicator enable pin indicator LEDs will flash as the enable pin cycles between states Figure 11 This test shows how the enable pin is...

Страница 11: ...l be limited to the short circuit current limit level After some time the device will enter thermal shutdown due to the high current and voltage between VCC and source output voltage pins An auto retr...

Страница 12: ...controlled slew rate changes When J6 is in place the slew rate will be longer because a capacitor is connected between the dv dt pin and GND With VCC set to 5 V press and release the blue button to se...

Страница 13: ...he 5 V power cable and plug it into the demo board Observe that the eFuse turns on with no issue and the output voltage rises in a controlled fashion Figure 14 This shows a standard hot plug test The...

Страница 14: ...the thermal shutdown level and latches off An auto retry eFuse MT2 part number suffix does not latch and automatically cycles the enable pin For auto retry eFuses the demo board s green and yellow in...

Отзывы: