NCP102 Demonstration Board Test Procedure 

 Required Equipment: 

 

1. 

3 DC Power Supplies:

  

a. 

“Vin supply” possessing a minimum voltage rating of 5 VDC 
and minimum current rating of 4 ADC; for example,  HP 
6282A. 

b. 

“Vcc supply” possessing a minimum voltage rating of 15 
VDC and minimum current rating of 1 ADC; for example, ½ 
Agilent e3649A dual supply. 

c. “N_Enable 

supply” 

possessing 

a minimum voltage rating of 

5.5 VDC and minimum current rating of 0.1 ADC; for 
example, ½ Agilent e3649A dual supply. 

 
2. 

3 Auto-ranging Digital Multimeters (DMMs):

  each 

possessing a minimum voltage rating of 20 VDC and 
minimum current rating of 2ADC; for example, Keithley 175. 

 
3. 

1 Electronic Load:

  possessing a current display and 

minimum current capability of 4 ADC; for example, Kikusui 
PLZ303W. 

 

Test Procedure: 

Establish Setup 

1. 

Connect the NCP102 Demonstration Board as shown in 
Figure 1.   

2. 

Adjust the N_Enable supply to 4.5VDC while observing the 
indicator on the supply. 

 
Note:  for measurement accuracy, the DMMs must be connected 
to the Demonstration Board terminals and not the DC supply or 
load terminals.  This is particularly true for DMM 2 and DMM 3. 
 
3. 

Connect DMM 1 to Vcc and configure as a voltmeter.  Set 
DMM 1for auto-range. 

4. 

Connect DMM 2 to Vin and configure as a voltmeter.  Set 
DMM 2 for auto-range. 

5. 

Connect DMM 3 to Vout and configure as a voltmeter.  Set 
DMM 3 for auto-range. 

1/22/08 