background image

FUSB302GEVB

www.onsemi.com

2

connects the I

2

C master to the FUSB302. The EVB

automatically generates a regulated 1.8 V supply, U6, which

is used by an external I

2

C translator to set the I

2

C levels used

with the FUSB302.

Regulator

for 1.8V IO

PC

Connector

Test Points

PIC programming

Port

Status

LEDs

Type

C

Connector

3.3V Regulator

Figure 1. EVB Layout

TYPE

C SIGNAL CONNECTIONS

The FUSB302 EVB allows different ways of connecting

to another Type

C device or controlling the signals of the

Type

C receptacle based on the type of testing that is

required.

CC Pins

The Type

C CC1 and CC2 pins are directly connected to

the Type

C receptacle J1 on the board. There is also a test

point for each pin that can be used to connect the CC pins
externally. Note that the FUSB302 EVB contains the
minimum cReceiver capacitance specified in the USB PD
specification for the CC pins which is 200pF. This
capacitance is C6 and C7 in the schematic.

VBUS

VBUS is used differently based on the Type

C port type.

As a sink port, VBUS is directly connected to the Type

C

receptacle J1 and the VBUS test point located near J1. As a
source port, VBUS can be supplied to the receptacle J1 and
controlled by the FUSB302 GUI. When controlled by the
FUSB302 software, VBUS is supplied from the PC micro

B

USB connection. The FUSB302 software uses an on board

load switch to control the enabling of VBUS to the Type

C

receptacle.

VCONN

VCONN is supplied to the FUSB302 from the VBUS pin

of the PC connection. To supply VCONN externally,
remove R6 and apply the external VCONN to the VCON test
point. Note that the EVB has 10

µ

F on VCONN input of the

FUSB302 which is the minimum bulk capacitance specified
in the Type

C specification. This capacitance is C4.

USB2.0 and SBU

They are left open in the Type

C connector and no

connections in the board.

STATUS LEDs

The following status LEDs are provided on the EVB.

Table 1. STATUS LEDs

LED

Status

D1

VDD is Supplied to FUSB302

D2

VCONN is Supplied to FUSB302

Содержание FUSB302 Type-C

Страница 1: ...or a Type C plug with a fixed CC and VCONN channel Full Type C 1 3 support Integrates the following functionality of the CC pin Attach detach detection as source Current capability indication as sourc...

Страница 2: ...This capacitance is C6 and C7 in the schematic VBUS VBUS is used differently based on the Type C port type As a sink port VBUS is directly connected to the Type C receptacle J1 and the VBUS test poin...

Страница 3: ...FUSB302GEVB www onsemi com 3 SCHEMATIC Figure 2 FUSB302 EVB FM150702B Schematic 1 2...

Страница 4: ...FUSB302GEVB www onsemi com 4 Figure 3 FUSB302 EVB FM150702B Schematic 2 2...

Страница 5: ...ates Disconnected then there is a connection problem Upgrading the GUI Software 1 Simply delete the previous version of the exe 2 Repeat the installation process above GUI OPERATION Program Startup To...

Страница 6: ...Device Control Tabs Tabs provide detailed control and monitoring of the FUSB302 The sections below describe how to use these controls General USB The General USB tab implements functional Type C state...

Страница 7: ...ackets The other control boxes indicate the current state of the PD state machine and what contract was negotiated When connected as a sink it displays the source capabilities of the source that is at...

Страница 8: ...esolution To stop logging click the Auto Poll option in the Preferences menu An example of a Type C attach and the PD communication flow is shown below To support debug efforts the Set State button ca...

Страница 9: ...pond once a connection is made It is the programmed source and sink capabilities of the device and the charging algorithm that is used to automatically select a source capability when connected to a s...

Страница 10: ...on tells the GUI to automatically check the DEVICE_ID register for the I2C address selected in the Addr pull down box and display the Device Connected or No Device message in the lower left corner of...

Страница 11: ...g from 3 consecutive registers r 0 0x42 3 0x04 read 3 bytes starting at MEASURE register address 0x04 An example of writing to 2 consecutive registers w 0 0x42 2 0x0E 0x22 0x55 write 2 bytes starting...

Страница 12: ...the EVB Right clicking on the Sop field allows you to add SVIDs Right clicking on an SVID allows you to remove the SVID or add a Mode Right clicking on a Mode allows you to remove it Retrieving VDM i...

Страница 13: ...ems or any FDA Class 3 medical devices or medical devices with a similar or equivalent classification in a foreign jurisdiction or any devices intended for implantation in the human body Should you pu...

Отзывы: