CONTROL SIGNAL INTERFACE
IOMAXnet ADAPTER MODULE
MAXnet User’s Manual
4-10
4.10. IOMAXnet
ADAPTER
MODULE
The optional IOMAXnet is an adapter module designed to provide easy connection for each
signal of the MAXnet. It incorporates two-row terminal block. It is used with a 10 foot shielded
cable to connect to the MAXnet via the 100-pin connector. The +5VDC on the IOMAX is supplied
by the MAXnet.
This supply voltage is intended to be utilized with accessories used in conjunction with the
MAXnet such as sensors, motor driver modules, etc. and supports a maximum current of 0.5
amps for these purposes.
TABLE 4-2
IOMAXnet – Terminal Block Pin-Out
Pin
Signal
Pin
Signal
Pin
Signal
1
X / V Phase +A
35
T / W Aux
69
Y / R Negative Limit
2
X / V Phase -A
36
U / K Aux
70
Z / S Negative Limit
3
X / V Phase +B
37
GROUND
71
T / W Negative Limit
4
X / V Phase -B
38
IO0 / IO8
72
U / K Negative Limit
5
X / V Index +
39
IO2 / IO10
73
GROUND
6
X / V Index -
40
IO4 / IO12
74
X / V Direction
7
Z / S Phase +A
41
IO6 / IO14
75
Y / R Direction
8
Z / S Phase –A
42
GROUND
76
Z / S Direction
9
Z / S Phase +B
43
ADC 0 / ADC 2
77
GROUND
10
Z / S Phase –B
44
GROUND
78
T / W Direction
11
Z / S Index +
45
X / V Servo
79
U / K Direction
12
Z / S Index -
46
GROUND
80
GROUND
13
U / K Phase +A
47
Z / S Servo
81
X / V Step
14
U / K Phase –A
48
GROUND
82
Y / R Step
15
U / K Phase +B
49
U / K Servo
83
Z / S Step
16
U / K Phase –B
50
GROUND
84
GROUND
17
GROUND
51
Y / R Phase +A
85
T / W Step
18
X / V Positive Limit
52
Y / R Phase –A
86
U / K Step
19
Y / R Positive Limit
53
Y / R Phase +B
87
GROUND
20
Z / S Positive Limit
54
Y / R Phase -B
88
IO1 / IO9
21
T / W Positive Limit
55
Y / R Index +
89
IO3 / IO11
22
U / K Positive Limit
56
Y / R Index -
90
IO5 / IO13
23
GROUND
57
GROUND
91
IO7 / IO15
24
X / V Home
58
GROUND
92
GROUND
25
Y / R Home
59
T / W Phase +A
93
ADC 1 / ADC 3
26
Z / S Home
60
T / W Phase –A
94
GROUND
27
GROUND
61
T / W Phase +B
95
Y / R Servo
28
T / W Home
62
T / W Phase –B
96
GROUND
29
U / K Home
63
T / W Index +
97
T / W Servo
30
GROUND
64
T / W Index -
98
GROUND
31
X / V Aux
65
U / K Index +
99
DAC 0 / DAC 1
32
Y / R Aux
66
U / K Index -
100
GROUND
33
Z / S Aux
67
GROUND
34
5 Volts
68
X / V Negative Limit
Legend
X / V axis
U / K axis
Y / R axis
Ground
Z / S axis
Voltage
T / W axis
For a black and white version of this table, click
Содержание MAXnet
Страница 4: ...TABLE OF CONTENTS MAXnet User s Manual ii This page is intentionally left blank ...
Страница 26: ...GETTING STARTED POWER SUPPLY REQUIREMENTS 2 20 MAXnet User s Manual This page is intentionally left blank ...
Страница 46: ...STAND ALONE COMMANDS MAXnet User s Manual 6 2 This page intentionally left blank ...
Страница 48: ...SERVICE MAXnet User s Manual 7 2 This page intentionally left blank ...
Страница 58: ...LIMITED WARRANTY APPENDIX A MAXnet User s Manual This page intentionally left blank ...
Страница 60: ...RETURN FOR REPAIRS APPENDIX B MAXnet User s Manual This page intentionally left blank ...