UNIT
No. of connected Power
Sensor Station/Monitor
1 to 31
Sets the number of connected Power Sensor Stations/Monitors.
1
REC
-
-
-
-
-
-
-
-
-
-
UTOFS
Unit No. offset setting
1 to 99
1
●
FUN mode
■
Major Error Displays and Countermeasures
E1100
E2001
E2002
E2003
E3000
E3002
E3003
E5000
E5001
E5002
HARD
Display
Description
Failed to write recorded data to the SD memory card. Insert a write-enabled SD card. Hold the MODE key for 3 seconds or more to cancel the error display.
A sensor different from the one auto-registered at startup is mounted. Restart the unit.
Communication with the sensor failed. Check the wiring between the sensor and the main unit. To cancel the error display, press and hold the MODE key for 3 seconds or more.
Failed to register the sensor in the initial processing on startup. Check the wiring between the sensor and the main unit, and restart the main unit.
If you turn on the power of the main unit before the sensor starts up, the sensor cannot be properly registered.
An SD memory card is not inserted. Insert a write-enabled SD card. Hold the MODE key for 3 seconds or more to cancel the error display.
The SD memory card is write-protected. Replace it with a write-enabled one. Hold the MODE key for 3 seconds or more to cancel the error display.
Failed to recognize the SD card. Insert a normal SD memory card. Hold the MODE key for 3 seconds or more to cancel the error display.
The setting data in the SD memory card is invalid e.g. an invalid model type or setting values. Hold the MODE key for 3 seconds or more to cancel the error display.
Failed to write setting files to the SD memory card. Insert a write-enabled SD card. Hold the MODE key for 3 seconds or more to cancel the error display.
There is no setting files contained in the SD memory card. Replace it with an SD memory card with setting files.
Hold the MODE key for 3 seconds or more to cancel the error display.
There may be a failure on the hardware. Please contact the distributor or OMRON representative office.
Overview
Recorded data writing failure
Sensor error
Sensor communications error
Sensor registration failed
No SD memory card inserted
Write-protected SD memory card
SD card recognition error
Invalid setting file data
Setting file writing failure
Setting file reading failure
Hardware error
■
List of Major Setting Items
RUN
FUN
THR
Mode
Description
Performs measurement/recording.
Sets various parameters.
Performs condition settings regarding alarm outputs.
Item
Measurement execution mode
Function setting mode
Threshold setting mode
●
Operation mode
Item
Overview
Setting range
Description
Default
Specifies the starting (offset) unit number set for the Power Sensor/Monitor units to
be connected. To use the unit numbers from No.10 to No.15, for example, "10" is set
for the offset number (this setting item), while "6" is set for the number of Power
Sensor/Monitor units to be connected (UNIT).
CYCLE
Recording interval setting
1s/2s/5s/10s
20s/30s/1min
Sets an recording interval of the measured value.
10s
Recording operation mode setting
CONT/RING
Sets operation for a case in which the internal memory capacity reaches the limit during recording.
CONT
CONT
Continue mode
Outputs a recorded value to the SD card and continues recording when the
internal memory capacity reaches the limit during recording.
RING
Ring mode
Overwrites a recorded value to the SD card and continues recording when the
internal memory capacity reaches the limit during recording.
INTEG
Setting of reset interval of
integrated power consumption
OFF/30 m
1 h/24 h
Specifies the integrated power reset interval. The integrated power value is reset at the
specified time interval, displaying the data belonging to that interval.
OFF
INIT
Setting initialization
Initializes the unit setting to the factory default value. Holding the SET/REC/STOP key
starts initialization. Changing measurement operation mode with the MODE key after
DONE is displayed initializes the settings and the unit restarts.
ETC
Display setting for other items
OFF/DISP
Sets whether displaying other setting items.
OFF
RESTR
Read setting data
Recovers the setting from the SD card in which the setting data
of the sensor unit is stored. Insert the SD card and hold the
SET/REC/STOP key. Writing completes when DONE is displayed.
BCKUP
Write setting data
Writes the setting data of the sensor unit to the SD card as a backup. Insert the SD card
and hold the SET/REC/STOP key. Writing completes when DONE is displayed.
CLOCK
Time setting
OFF/DISP
Sets whether displaying the time setting item.
OFF
RATE
Rate conversion setting
0.000 to 99.999
Sets the conversion coefficient to convert the integrated power consumption to rate.
0
CONV
Conversion unit setting
JPY/USD/EUR
CNY/KRW/CO2
Sets the conversion unit.
JPY
REREC
Power failure REC restoration
OFF/ON
Sets whether writing data and starting recording at next startup
after power shutdown during recording.
OFF
INT H (Unit: kWh)
Displayed item
Setting range
0 to 99999
Overview
Upper threshold setting of the integrated power consumption (kWh or more)
Default
0
●
THR mode
■
Connected Units and Recording Interval
1 second
2 seconds
5 seconds
10 seconds
20 seconds
30 seconds
1 minute
Minimum recording interval
1 unit
Up to 2 units
Up to 6 units
Up to 12units
Up to 24 units
Number of units
Up to 31 units
The possible minimum recording interval varies depending on the number of power
sensors/monitors. Check the following table of the number of units that can be
connected to set the recording interval.
■
Recording Interval and Internal Memory
Recording Interval
Approx. 1 hr. 50 min.
Approx. 3 hr. 40 min.
Approx. 9 hr. 30 min.
Approx. 19 hr.
Approx. 1 day 14 hr.
Approx. 2 days
Approx. 4 days
Min. load
(KM20 x 1 unit)
-
-
-
-
-
Approx. 1 hr. 40 min.
Approx. 3 hr. 20 min.
Max. load
(KM50 x 31 units)
Example of possible recording time in the internal memory
An example of the possible recording time in the internal memory that varies
depending on the recording interval setting is shown below.
1 second
2 seconds
5 seconds
10 seconds
20 seconds
30 seconds
1 minute
IP
IP address display setting
OFF/DISP
Sets whether performing IP address setting.
OFF
●
Notice for Korea Radio Law
A급 기기(업무용 방송통신기자재)
이 기기는 업무용(A급) 전자파적합기기로서 판매자
또는 사용자는 이 점을 주의하시기 바라며,가정외의
지역에서 사용하는 것을 목적으로 합니다.
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
O c t , 2 0 1 4
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters